PEDROLLO-LOGO

PEDROLLO CB2 Fixed Speed Pressure Units

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-PRODUCT

  • Domestic use
  • Civil use
  • Industrial use
  • Agricultural use

INSTALLATION AND USE

CB2 is a pre-assembled pumping system comprising two pumps, designed for water supply and pressurization in residential, commercial, and public buildings, hotels, and hospitals, as well as for garden and agricultural irrigation. CB2 is suitable for pumping clean water or aqueous solutions that do not chemically or mechanically damage the materials used and do not contain abrasive or fibrous sub-stances.

PRODUCT DESCRIPTION

CB2 is a pressurization system featuring two pumps assembled in a unit, ready for connection to the water mains or a primary collection tank. Controlled by mechanical pressure switches, CB2 ensures automatic activation of one or both pumps in response to increased user demand, optimizing water supply and minimizing electricity consumption. The system’s electronic circuitry facilitates automatic pump switching during start/stop cycles and protects against potential faults.

COMPONENTS

  • Pumps connected in parallel via suction and discharge manifolds. Each unit is equipped with ball valves on the discharge and suction side, non-return valves on the suction side (with 2CP, 3-5CR, FCR, MK pumps), or on the discharge side (with HT pumps).
  • BASE is made of metal profile and fitted with adjustable vvibration-dampingfeet.
  • PRESSURE SWITCHES mounted on the delivery manifold and connected to the electrical panel for switching the pumps on and off according to regulation.
  • ELECTRONIC ELECTRICAL PANEL (model E2) protects against dry running by monitoring electrical parameters and allows advanced users to adjust settings to tailor the operation of the pressure unit to specific sys-tem requirements.
  • Power supply:
    • CB2m: single-phase 230 V – 50 Hz
    • CB2: three-phase 400 V – 50 Hz

CB2 – 2CP
Pressurization unitscompriseg two twin impeller centrifugal pumps, designed to enhance water pressure. Ideal for both residential and commercial water supply applications, they are well-suited for large-scale garden and agricultural irrigation. They also excel at handling clean water in various industrial settings.

TECHNICAL DATA

  • Liquid temperature between +5 °C and +55 °C
  • Ambient temperature between +5 °C and +40 °C
  • Max. pressure in the pump body 10 bar (6 bar for 2CP25/130)
  • Continuous running duty S1

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-1

CB2 – 3-5CR
Pressurization units comprising two multistage centrifugal pumps. They are well-suited for domestic water supply, garden irrigation, and gen-eral clean water handling.

TECHNICAL DATA

  • Liquid temperature between +5 °C and +55 °C
  • Ambient temperature between +5 °C and +40 °C
  • Max. pressure in the pump body 7 bar
  • Continuous running duty S1PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-2

CB2 – FCR
Pressurization units comprising two horizontal multistage centrifugal pumps. Especially well-suited for residential and commercial water supply, in-dustrial pressure boosting, and gar-den and field irrigation.

TECHNICAL DATA

  • Liquid temperature between +5 °C and +55 °C
  • Ambient temperature between +5 °C and +40 °C
  • Max. pressure in pump body 11 bar (for FCR 80-100 7 bar)
  • Continuous running duty S1PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-3

CB2 – HT
Pressurization units comprising two vertical multistage centrifugal pumps. They are well-suited for residential and commercial water supply, ir-rigation, and general clean water handling, including industrial appli-cations

TECHNICAL DATA

  • Liquid temperature between +5 °C and +55 °C
  • Ambient temperature between +5 °C and +40 °C
  • Max. pressure in the pump body 16 bar
  • Continuous running duty S1

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-4

FIELD AND PERFORMANCE DATA

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-6

TYPE POWER P2 Q m³/h 0 2.4 4.8 7.2 9.6 10.8 12.0 13.2 14.4 16.8 19.2
Single-phase Three-phase kW HP l/min 0 40 80 120 160 180 200 220 240 280 320
CB2 2CPm 25/130 2×0.75 2×1  

 

H metres

42 39 34.5 28.5 22 18 15        
CB2 2CPm 25/14B CB2 2CP 25/14B 2×1.1 2×1.5 54 52 47.5 41 32.5 27.5 22        
CB2 2CPm 25/16C CB2 2CP 25/16C 2×1.1 2×1.5 47 46 44 40.5 36 33.5 30.5 27.5 24    
CB2 2CPm 25/16B CB2 2CP 25/16B 2×1.5 2×2 58 56 54 51 47.5 45.5 43 40 37 30  
CB2 2CP 25/16A 2×2.2 2×3 68 67 65 62 58.5 56 54 51 48 40.5 32
TYPE POWER P2 Q m³/h 0 4.8 7.2 9.6 12.0 14.4 16.8 19.2 21.6 24.0 30.0
Single-phase Three-phase kW HP l/min 0 80 120 160 200 240 280 320 360 400 500
CB2 2CP 32/200C 2×3 2×4  

 

H metres

70 67 65 63 60.5 58 55 52 48.5 45.5 36
CB2 2CP 32/200B 2×4 2×5.5 85 81 79 77 74.5 71.5 69 66 62.5 59 49
CB2 2CP 32/210B 2×5.5 2×7.5 94 94 93 91 89 86 83 79 75 70 56
CB2 2CP 32/210A 2×7.5 2×10 112 111 110 109 107 105 102 99 95 90 74
TYPE POWER P2 Q m³/h 0 12 18 24 30 36 42 48 54
Single-phase Three-phase kW HP l/min 0 200 300 400 500 600 700 800 900
CB2 2CP 40/180C 2×4 2×5.5  

H metres

65 63 60 55.5 50 43 35    
CB2 2CP 40/180B 2×5.5 2×7.5 80 78 75 71 65.5 59 51 42  
CB2 2CP 40/180A 2×7.5 2×10 92 90 87.5 84 79 73.5 66 58 48
  • The data shown in the diagram and tables indicate performance with 2 pumps in operation

PERFORMANCE CURVES

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-7 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-8PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-9

ABSORPTION

TYPE

Single-phase

VOLTAGE

230 V

CB2 2CPm 25/130 2 x 6.3 A
CB2 2CPm 25/14B 2 x 7.7 A
CB2 2CPm 25/16C 2 x 7.7 A
CB2 2CPm 25/16B 2 x 10.0 A
TYPE

Three-phase

VOLTAGE

400 V

CB2 2CP 25/14B 2 x 3.1 A
CB2 2CP 25/16C 2 x 3.1 A
CB2 2CP 25/16B 2 x 4.0 A
CB2 2CP 25/16A 2 x 5.3 A
CB2 2CP 32/200C 2 x 7.4 A
CB2 2CP 32/200B 2 x 10.5 A
CB2 2CP 32/210B 2 x 12.5 A
CB2 2CP 32/210A 2 x 16.0 A
CB2 2CP 40/180C 2 x 9.8 A
CB2 2CP 40/180B 2 x 12.3 A
CB2 2CP 40/180A 2 x 15.4 A

DIMENSIONS AND WEIGHT

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-10

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2 a b c d e h h1 h2 1~ 3~
CB2 2CPm 25/130  

 

 

2″

 

 

 

1½”

727  

 

 

 

530

337  

 

 

 

270

 

 

 

 

510

 

 

 

 

 

 

 

674

152 390 60.0
CB2 2CPm 25/14B CB2 2CP 25/14B  

752

 

 

 

346

 

153

 

413

72.0 73.0
CB2 2CPm 25/16C CB2 2CP 25/16C 73.0 73.0
CB2 2CPm 25/16B CB2 2CP 25/16B  

761

 

170

 

451

80.0 80.0
CB2 2CP 25/16A 86.0
CB2 2CP 32/200C  

 

3″

 

 

2″

 

972

 

 

 

 

 

 

700

 

453

 

 

 

 

 

 

370

 

 

 

712

 

192

 

516

129.0
CB2 2CP 32/200B 135.0
CB2 2CP 32/210B  

977

 

456

 

 

 

 

199

 

546

161.0
CB2 2CP 32/210A 171.0
CB2 2CP 40/180C  

DN 100

4″

 

DN 80

3″

 

 

1048

 

 

468

 

 

774

 

 

716

 

 

590

190.0
CB2 2CP 40/180B 199.0
CB2 2CP 40/180A 211.0

FIELD AND PERFORMANCE DATA

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-11

TYPE POWER (P2) Q m³/h 0 0.6 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12 13.2 14.4 15.6
Single-phase Three-phase kW HP l/min 0 10 20 40 60 80 100 120 140 160 180 200 220 240 260
CB2 5CRm 80 CB2 5CR 80 2×0.75 2×1  

 

H metres

67 66 64 59 53 45.5 37.5 29.5 20.5 12          
CB2 – 4CRm 100 CB2 4CR 100 2×0.75 2×1 50 50 49 47 45 42 39.5 37 34 30.5 26.5 22 17 11 5
CB2 5CRm 100 CB2 5CR 100 2×0.90 2×1.25 63 62 61.5 59.5 57 53.5 50.5 46.5 42.5 38 33 28 22 15 8

Q = Flow rate H = Total manometric head Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

The data shown in the diagram and tables indicate performance with 2 pumps in operation

ABSORPTION

TYPE

Single-phase

VOLTAGE

230 V

CB2 5CRm 80 2 x 5.5 A
CB2 – 4CRm 100 2 x 5.8 A
CB2 5CRm 100 2 x 6.8 A
TYPE

Three-phase

VOLTAGE

400 V

CB2 5CR 80 2 x 2.5 A
CB2 4CR 100 2 x 2.3 A
CB2 5CR 100 2 x 2.5 A

PERFORMANCE CURVES

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-12 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-13

DIMENSIONS AND WEIGHT

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-14

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2 a b c d e h h1 h2 1~ 3~
CB2 5CRm 80 CB2 5CR 80 1½” 1½” 760 530 370 270 510 674 192 373 53 54
CB2 – 4CRm 100 CB2 4CR 100 2″ 1½”  

803

 

530

 

408

 

270

 

510

 

674

 

192

 

373

54 55
CB2 5CRm 100 CB2 5CR 100 56 55

FIELD AND PERFORMANCE DATA

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-15

TYPE POWER P2 Q m³/h 0 0.6 1.2 2.4 4.8 7.2 9.6 10.8 12 13.2 14.4 15.6
Single-phase Three-phase kW HP l/min 0 10 20 40 80 120 160 180 200 220 240 260
CB2 – FCRm 80/5 2×0.75 2×1  

 

 

 

H metres

67 66 64 59 45.5 29.5 12          
CB2 – FCRm 100/4 2×0.75 2×1 50 50 49 47 42 37 30.5 26.5 22 17 11 5
CB2 – FCRm 100/5 CB2 FCR 100/5 2×1.1 2×1.5 63 62 61.5 59.5 53.5 46.5 38 33 28 22 15 8
CB2 – FCRm 90/5 CB2 FCR 90/5 2×1.1 2×1.5 81 80 79 77 71 62.5 51 44        
CB2 – FCRm 130/4 CB2 FCR 130/4 2×1.5 2×2 68.5 68.5 68 67 65 62 57.5 55 52 48 45 41
CB2 FCR 130/5 2×1.8 2×2.5 86 85 85 84 81 77 72 68.5 65 73 67 51.5
TYPE POWER P2 Q m³/h 0 6 12 24 36 42 48
Single-phase Three-phase kW HP l/min 0 100 200 400 600 700 800
CB2 FCR 15/3 2×4 2×5.5  

H metres

72 70 68.5 61 48 38.5 27
CB2 FCR 15/4 2×5.5 2×7.5 96 94 91 81 64 51.5 36

The data shown in the diagram and tables indicate performance with 2 pumps in operation

PERFORMANCE CURVES

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-16 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-17

ABSORPTION

TYPE

Single-phase

VOLTAGE

230 V

CB2 – FCRm 80/5 2 x 5.5 A
CB2 – FCRm 100/4 2 x 5.8 A
CB2 – FCRm 100/5 2 x 6.8 A
CB2 – FCRm 90/5 2 x 9.0 A
CB2 – FCRm 130/4 2 x 10.3 A
TYPE

Three-phase

VOLTAGE

400 V

CB2 FCR 100/5 2 x 2.5 A
CB2 FCR 90/5 2 x 3.5 A
CB2 FCR 130/4 2 x 4.0 A
CB2 FCR 130/5 2 x 5.0 A
CB2 FCR 15/3 2 x 8.8 A
CB2 FCR 15/4 2 x 11.2 A

DIMENSIONS AND WEIGHT

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-18

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2 a b c d e h h1 h2 1~ 3~
CB2 – FCRm 80/5 1½” 1½” 672  

 

530

364  

 

270

 

 

 

 

510

 

 

 

 

674

 

 

182

 

 

368

53
CB2 – FCRm 100/4  

 

2″

 

 

1½”

 

715

 

401

56
CB2 – FCRm 100/5 CB2 FCR 100/5 56 56
CB2 – FCRm 90/5 CB2 FCR 90/5 805  

 

700

 

 

339

 

 

370

 

 

205

 

 

394

82 83
CB2 – FCRm 130/4 CB2 FCR 130/4 779 82 83
CB2 FCR 130/5 805 90
CB2 FCR 15/3 DN 100

4″

DN 80

3″

1058  

700

569  

490

 

774

 

704

 

211

 

565

179
CB2 FCR 15/4 1102 613 191

FIELD AND PERFORMANCE DATA

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-19

TYPE POWER P2 Q m³/h 0 1.2 2.4 4.8 7.2 9.6 12.0 14.4 16.8 19.2 21.6
Single-phase Three-phase kW HP l/min 0 20 40 80 120 160 200 240 280 320 360
CB2 – MKm 3/3 CB2 – MK 3/3 2×0.75 2×1  

 

 

 

 

 

 

H metres

52.5 51.5 50 45 38.5 29          
CB2 – MKm 3/5 CB2 – MK 3/5 2×1.1 2×1.5 87 85 83 75 64 48          
CB2 – MKm 3/6 CB2 – MK 3/6 2×1.5 2×2 105 103 100 90 77 58          
CB2 – MKm 5/4 CB2 – MK 5/4 2×0.75 2×1 57 54 50 45 37.5 28.5 17      
CB2 – MKm 5/5 CB2 – MK 5/5 2×1.1 2×1.5 71 67.5 62.5 56 47 35.5 21.5      
CB2 – MKm 5/7 CB2 – MK 5/7 2×1.5 2×2 99 95 88 78 66 50 30      
CB2 – MKm 5/8 CB2 – MK 5/8 2×2.2 2×3 114 108 100 90 75 57 34      
CB2 – MKm 8/4 CB2 – MK 8/4 2×1.1 2×1.5 56 53.5 51 47.5 43 37.5 30.5 22.1 12
CB2 – MKm 8/5 CB2 – MK 8/5 2×1.5 2×2 70 67 64 59.5 54 47 38 27.5 15.5
CB2 – MKm 8/6 CB2 – MK 8/6 2×2.2 2×3 84 80 77 72 64.5 56 45.5 33 18.5
  • The data shown in the diagram and tables indicate performance with 2 pumps in operation

PERFORMANCE CURVES

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-20 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-21 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-22

ABSORPTION

TYPE

Single-phase

VOLTAGE

230 V

CB2 – MKm 3/3 2 x 5.7 A
CB2 – MKm 3/5 2 x 7.8 A
CB2 – MKm 3/6 2 x 9.5 A
CB2 – MKm 5/4 2 x 5.7 A
CB2 – MKm 5/5 2 x 7.1 A
CB2 – MKm 5/7 2 x 9.3 A
CB2 – MKm 5/8 2 x 10.0 A
CB2 – MKm 8/4 2 x 7.8 A
CB2 – MKm 8/5 2 x 9.7 A
CB2 – MKm 8/6 2 x 11.1 A
TYPE

Three-phase

VOLTAGE

400 V

CB2 – MK 3/3 2 x 2.5 A
CB2 – MK 3/5 2 x 3.0 A
CB2 – MK 3/6 2 x 3.5 A
CB2 – MK 5/4 2 x 2.5 A
CB2 – MK 5/5 2 x 2.7 A
CB2 – MK 5/7 2 x 3.5 A
CB2 – MK 5/8 2 x 4.3 A
CB2 – MK 8/4 2 x 3.0 A
CB2 – MK 8/5 2 x 3.5 A
CB2 – MK 8/6 2 x 4.5 A

DIMENSIONS AND WEIGHT

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-23

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2 a b c d e h h1 h2 1~ 3~
CB2 – MKm 3/3 CB2 – MK 3/3  

 

 

 

2″

 

 

 

 

 

 

1½”

 

 

 

 

 

 

673

 

 

 

 

 

 

 

 

530

 

 

 

 

 

 

135

 

 

 

 

 

 

 

 

270

 

 

 

 

 

 

 

 

510

 

 

 

 

 

 

 

 

854

 

 

 

 

 

 

 

 

102

234 75.0 73.0
CB2 – MKm 3/5 CB2 – MK 3/5 288 76.0 77.0
CB2 – MKm 3/6 CB2 – MK 3/6 315 80.0 81.0
CB2 – MKm 5/4 CB2 – MK 5/4 261 76.0 74.0
CB2 – MKm 5/5 CB2 – MK 5/5 288 76.0 77.0
CB2 – MKm 5/7 CB2 – MK 5/7 342 81.0 81.0
CB2 – MKm 5/8 CB2 – MK 5/8 369 82.0 82.0
CB2 – MKm 8/4 CB2 – MK 8/4  

2½”

 

 

719

 

 

171

261 80.0 81.0
CB2 – MKm 8/5 CB2 – MK 8/5 288 81.0 81.0
CB2 – MKm 8/6 CB2 – MK 8/6 315 87.0 87.0

FIELD AND PERFORMANCE DATA

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-24

TYPE POWER (P2) Q m³/h 0 0.6 1.2 2.4 4.8 7.2 9.6 10.8
Single-phase Three-phase kW HP l/min 0 10 20 40 80 120 160 180
CB2 – HTm 3/4 CB2 – HT 3/4 2×0.75 2×1  

H metres

65 65 63.5 62 57 50 40.5 35
CB2 – HTm 3/5 CB2 – HT 3/5 2×1.1 2×1.5 81 80 79 77 71 62.5 51 44
CB2 – HTm 3/6 CB2 – HT 3/6 2×1.5 2×2 97 96 95 93 86 75 61 52
CB2 – HT 3/7 2×1.8 2×2.5 113 112 111 108 100 88 71 61
TYPE POWER (P2) Q m³/h 0 0.6 1.2 2.4 4.8 7.2 9.6 10.8 12 15.6
Single-phase Three-phase kW HP l/min 0 10 20 40 80 120 160 180 200 260
CB2 – HTm 5/2 CB2 – HT 5/2 2×0.75 2×1  

 

H metres

35 35 32.7 32.3 32.5 31 25.5 27.5 26 20.5
CB2 – HTm 5/3 CB2 – HT 5/3 2×1.1 2×1.5 51.5 51.5 51 50.5 49 46.5 43 41 39 31
CB2 – HTm 5/4 CB2 – HT 5/4 2×1.5 2×2 68.5 68.5 68 67 65 62 57.5 55 52 41
CB2 – HT 5/5 2×1.8 2×2.5 86 85 85 84 81 77 72 68.5 65 51.5
CB2 – HT 5/6 2×2.2 2×3 103 103 102 101 98 93 86 82 78 62
TYPE POWER (P2) Q m³/h 0 2.4 4.8 7.2 9.6 12 14.4 16.8 19.2 21.6 24
Single-phase Three-phase kW HP l/min 0 40 80 120 160 200 240 280 320 360 400
CB2 – HTm 8/3 CB2 – HT 8/3 2×1.1 2×1.5  

 

H metres

47 46.5 45.5 44 42 39.5 36.5 32.5 28 23.1 17
CB2 – HTm 8/4 CB2 – HT 8/4 2×1.5 2×2 62.5 62 60.5 58.5 56 53 48.5 43.5 37.5 31 23
CB2 – HT 8/5 2×1.8 2×2.5 78 77.5 76 73 70 66 61 54.5 47 38.5 28.5
CB2 – HT 8/6 2×2.2 2×3 94 93 91 88 84 79 73 65.5 56.5 46 34.5
CB2 – HT 8/7 2×3 2×4 109 108 106 103 98 92 85 76 66 54 40
TYPE POWER (P2) Q m³/h 0 3.6 6 7.2 9.6 14.4 18 20.4 24 26.4 30
Single-phase Three-phase kW HP l/min 0 60 100 120 160 240 300 340 400 440 500
CB2 – HTm 10/3 CB2 – HT 10/3 2×1.5 2×2  

 

H metres

47 45.5 44 43.5 42 38 33.5 30.5 24.7 20.3 13
CB2 – HTm 10/4 CB2 – HT 10/4 2×1.8 2×2.5 62 61 59 58 56 50.5 45 40.5 33 27 18
CB2 – HT 10/5 2×2.2 2×3 77 75.5 74 73 70 63 56 50.5 41 34 21.5
CB2 – HT 10/6 2×3 2×4 93 91 88 87 84 76 67.5 61 49.5 40.5 26
CB2 – HT 10/7 2×3 2×4 108 106 103 102 98 88 79 71 57.5 47.5 30
TYPE POWER (P2) Q m³/h 0 6 12 24 36 42 48
Single-phase Three-phase kW HP l/min 0 100 200 400 600 700 800
CB2 – HT 15/3 2×4 2×5.5 H metres 72 70 68.5 61 48 38.5 27
CB2 – HT 15/4 2×5.5 2×7.5 96 94 91 81 64 51.5 36

PERFORMANCE CURVES

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-25 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-26 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-27 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-28 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-29 PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-30

ABSORPTION

TYPE

Single-phase

VOLTAGE

230 V

CB2 – HTm 3/4 2 x 7.5 A
CB2 – HTm 3/5 2 x 9.0 A
CB2 – HTm 3/6 2 x 10.5 A
CB2 – HTm 5/2 2 x 6.1 A
CB2 – HTm 5/3 2 x 8.5 A
CB2 – HTm 5/4 2 x 10.3 A
CB2 – HTm 8/3 2 x 8.7 A
CB2 – HTm 8/4 2 x 10.5 A
CB2 – HTm 10/3 2 x 9.5 A
CB2 – HTm 10/4 2 x 11.0 A
TYPE

Three-phase

VOLTAGE

400 V

CB2 – HT 3/4 3.0 A
CB2 – HT 3/5 3.5 A
CB2 – HT 3/6 4.0 A
CB2 – HT 3/7 4.8 A
TYPE

Three-phase

VOLTAGE

400 V

CB2 – HT 5/2 2 x 2.8 A
CB2 – HT 5/3 2 x 3.2 A
CB2 – HT 5/4 2 x 3.8 A
CB2 – HT 5/5 2 x 4.8 A
CB2 – HT 5/6 2 x 5.2 A
CB2 – HT 8/3 2 x 3.3 A
CB2 – HT 8/4 2 x 4.0 A
CB2 – HT 8/5 2 x 4.8 A
CB2 – HT 8/6 2 x 5.4 A
CB2 – HT 8/7 2 x 7.0 A
CB2 – HT 10/3 2 x 3.4 A
CB2 – HT 10/4 2 x 4.5 A
CB2 – HT 10/5 2 x 5.2 A
CB2 – HT 10/6 2 x 6.5 A
CB2 – HT 10/7 2 x 7.2 A
CB2 – HT 15/3 2 x 8.8 A
CB2 – HT 15/4 2 x 11.2 A

DIMENSIONS AND WEIGHT

PEDROLLO-CB2-Fixed-Speed-Pressure-Units-FIG-31

TYPE PORTS DIMENSIONS mm kg
Single-phase Three-phase DN1 DN2 a b c d e h h1 h2 1~ 3~
CB2 – HTm 3/4 CB2 – HT 3/4  

2″

 

2″

 

732

 

530

 

614

 

270

 

510

674  

135

569 99 100
CB2 – HTm 3/5 CB2 – HT 3/5 595 100 100
CB2 – HTm 3/6 CB2 – HT 3/6 854 621 102 102
CB2 – HT 3/7 667 112
CB2 – HTm 5/2 CB2 – HT 5/2  

 

2″

 

 

2″

 

 

779

 

 

530

 

 

661

 

 

270

 

 

510

 

674

 

 

135

517 99 100
CB2 – HTm 5/3 CB2 – HT 5/3 543 99 100
CB2 – HTm 5/4 CB2 – HT 5/4 569 103 104
CB2 – HT 5/5 854 615 109
CB2 – HT 5/6 641 111
CB2 – HTm 8/3 CB2 – HT 8/3  

 

2½”

 

 

2½”

 

 

873

 

530

 

 

738

   

270

 

 

521

674  

 

140

548 106 107
CB2 – HTm 8/4 CB2 – HT 8/4 574 110 111
CB2 – HT 8/5 854 620 119
CB2 – HT 8/6 646 120
CB2 – HT 8/7 700   370 674 724 145
CB2 – HTm 10/3 CB2 – HT 10/3  

2½”

 

2½”

 

873

 

530

 

738

 

270

 

521

674  

140

548 107 107
CB2 – HTm 10/4 CB2 – HT 10/4 594 111 111
CB2 – HT 10/5 854 620 119
CB2 – HT 15/3 3″ 3″ 993 700 850 370 728 674 150 693 175
CB2 – HT 15/4 737 187

Documents / Resources

PEDROLLO CB2 Fixed Speed Pressure Units [pdf] Instructions
CB2 Fixed Speed Pressure Units, CB2, Fixed Speed Pressure Units, Speed Pressure Units, Pressure Units, Units

References

Leave a comment