E600 LFP Expandable Portable Power
“
Specifications
- Capacity: 614Wh (25.6V24Ah)
- Battery Type: LiFePO4 Battery Retain 80%+ Original Capacity At
3500 Cycles - Protections: Over-Voltage, Overheat, Overload, Short-Circuit,
Self-Recovery - Dimension: L11.7*W7.8*H8.5 in / L298*W199*H215 mm
- Net Weight: Around 20lb / Around 9.2kg
- AC Output: Pure sine wave 100V~120V Rated 1200W
- USB-A: (5V, 9V, 12V, Max 18W) * 2
- USB-C: (5V, 9V, 12V, Max 18W) * 1 / (5V, 9V, 12V, 20V, Max
100W) * 1
Product Usage Instructions
Turning the Device On/Off
To turn on/off DC/USB/Wireless Charger: Press and hold the
corresponding button.
To turn on/off AC: Press and hold the AC button. Turn off the AC
function if there is no AC load on the unit.
LCD Smart Display
The LCD display shows various information including AC output
wattage, battery status, voltage, temperature, and more.
Charging Indicator
The unit indicates the net input/output wattage and charge
status through the display.
Using Solar Panels to Charge the E600 LFP
Charging with One Solar Panel
Connect the MC4 Solar Charging Cable to the GX16MF-5 Charging
Port. Ensure the solar panel’s VOC is less than 60V.
Charging with Two Solar Panels in Parallel
Use a Y Branch MC4 Charging Cable to connect two solar panels in
parallel to the GX16MF-5 Charging Port.
FAQ
Q: What is the maximum input voltage for solar panel
charging?
A: The maximum input voltage for solar panel charging is 60V
with a maximum power of 350W.
Q: How can I know if my devices are exceeding the power limit
of 1200W?
A: The AC overload alarm indicator will flash and the unit will
stop supplying power if your devices exceed 1200W.
Q: Can I use third-party solar panels to charge the E600
LFP?
A: It is recommended to use PECRON solar panels for optimal user
experience to ensure compatibility and performance.
“`
E600 LFP
DC INPUT 10V~60V/350W(MAX)
AC OUTPUT-1200W
DC OUT AC OUT
DC OUTPUT
12V-10A
100W
18W
18W
USB
18W
USER MANUAL
Please read the user manual thoroughly before using support@pecron.com
FUNCTION INTRODUCTION
DC INPUT 10V~60V/350W(MAX)
AC OUTPUT-1200W
DC OUT AC OUT
DC OUTPUT
12V-10A
100W
18W
18W
18W
USB
LCD Display DC 10V~60V Charging Port AC 100V~120V Output
Wireless Charger DC 12V/USB/Wireless Switch AC 100V~120V Switch
DC12V Auxiliary Output DC12V(5525)Output USB-A/USB-C Ports
support@pecron.com
SPECIFICATIONS
Capacity
614Wh (25.6V24Ah)
Battery Type
LiFePO4 Battery Retain 80%+ Original Capacity At 3500 Cycles
OUTPUT SPECS
Protections
Over-Voltage, Overheat, Overload, Short-Circuit, Self-Recovery
Dimension
L11.7*W7.8*H8.5 in L298*W199*H215 mm
Net Weight
Around 20lb Around 9.2kg
AC Output *3
Pure sine wave 100V~120V Rated 1200W
USB-A *2
(5V,9V,12V, Max 18W)*2
INPUT SPECS
USB-C *2
(5V,9V,12V, Max 18W)*1 (5V,9V,12V,20V, Max 100W)*1
Cigar Port *1 DC 12V 10A
DC 5525 Output *2 DC 12V 5A
Wireless Charger *1 Max 15W
GX16MF *1
DC Charging(10V~60V) Max 350W
support@pecron.com
HOW TO USE THE E600 LFP
press and hold to turn on / off DC / USB / Wireless Charger press and hold to turn on / off AC (Please turn off the AC function if there is no AC load on the unit)
LCD SMART DISPLAY
AC Output Wattage(%) AC Overload Alarm Battery Soc(%) Voltage(V) Temperature Alarm
DC INPUT 10V~60V/350W(MAX)
AC OUTPUT-1200W
DC OUT AC OUT
DC OUTPUT
12V-10A
100W
18W
18W
18W
USB
DC Out
Net Input/Output Wattage Charge Indicator
AC Output Wattage(W)/Voltage(V) AC Out PF Value/Remaining Charging/ Discharging Time(Hrs) Time Indicator
AC Overload Alarm Icon E600 LFP can power most devices with consumption power less than 1200 watts. If your devices exceed 1200W, The AC overload alarm indicator will flash, The unit will stop supplying power.
support@pecron.com
PACKING LIST
DC INPUT 10V~60V/350W(MAX)
AC OUTPUT-1200W
DC OUT AC OUT
DC OUTPUT
12V-10A
100W
18W
18W
USB
18W
PECRON E600 LFP *1
AC Charger *1
MC4 Solar Charging Cable(LSMC4-5GX16) *1
Car Charging Cable *1
USING SOLAR PANELS TO CHARGE THE E600 LFP
GX16MF-5 Charging Port: PV(operating voltage) range 10V~60V, 350W maximum; VOC(open circuit voltage) of solar panel/array must be less than 60V, otherwise, it will damage the unit! It’s prohibited to connect 2pcs of solar panels whose VOC are more than 30V in series. If you have any questions, Please feel free to contact ussupport@pecron.com
DC INPUT
DC INPUT 10V~60V/350W(MAX)
AC OUTPUT-1200W
DC OUT AC OUT
DC OUTPUT
12V-10A
100W
18W
18W
18W
USB
GX16MF-5 Charging Port: PV10~60V-350W Maximum Input
10V~60V/350W(MAX) support@pecron.com
USING SOLAR PANELS TO CHARGE THE E600 LFP
Charging the E600 LFP with one solar panel
DC INPUT
10V~60V/350W(MAX)
MC4 Solar Charging Cable*1 It is recommended to choose PECRON solar panels for optimal user experience! The VOC of a single solar panel should be
less than 60V, and the VMP should be greater than 10V.
Use two solar panels in parallel to charge the E600 LFP
DC INPUT
10V~60V/350W(MAX)
MC4 Solar Charging Cable*1 Y Branch MC4 Charging Cable(+)*1 Y Branch MC4 Charging Cable(-)*1 (NOTEThis parallel charging cable sold separately) It is recommended to choose PECRON solar panels for optimal user experience! The VOC of a single solar panel should be less than 60V, and the VMP should be greater than 10V.
support@pecron.com
FAQS
Q1 What kind of battery is used in E600 LFP? How long it can last? A E600 LFP utilizes high quality UL certified automotive LiFePO4 battery, it can retain 80% of its original capacity at 3500 complete charge cycles.
Q2 What devices can E600 LFP power? A The AC output ports can power appliances which use less than 1200 watts of electricity. However, inductive types of loads such as freezer, fridge, compressor, motor require a much higher power to start (approx. 3-7 time lager than its rated power) The DC output ports can supply a maximum DC power of 120W(12V@10A).
Q3 Can the E600 LFP be used as UPS? A The UPS function is not supported.
Q4 Can the E600 LFP be charged while discharging? A Yes, E600 LFP can run devices while it is being charged. The battery will eventually run out if the discharging is greater than the charging during the pass through charging.
Q5 How to calculate the E600 LFP running time? A Running Time=Total Capacity(614Wh) * 0.85 (Depth of Discharge)/Loading Power(Watts)
Q6 Can I use the E600 LFP indoors and charge the E600 LFP indoors? A Yes, the E600 LFP is safe to use indoors.
Q7 Does E600 LFP have built-in MPPT controller? A Yes, there is one independent built-in MPPT controller; “GX16″port supports 10~60V(Max 350W) PV input.
Q8 How to store the E600 LFP? A Please turn off the unit and then store it in a dry, ventilated place at normal room temperature. Do not place this unit near water sources or a wet/moist environment. For long-term storage, it is recommended to discharge the battery to 30% every three months and recharge it to 60% to sustain the battery life.
support@pecron.com
DISCLAIMER
Please read the user manual thoroughly before using this product, and keep this manual in a safe place for future reference. Failure to follow the instructions for proper set up, use, and care for the device can increase the risk of serious personal injury, death, or property damage. Once you use this device, you are deemed to have understood, recognized and accepted all terms and contents of this document. The user shall be responsible for his own actions and all consequences arising from failure to use the device in accordance with the “User Manual”, or as authorized in PECRON’s current product literature. In compliance with laws and regulations, PECRON reserves all rights for final explanation, and to change these terms and conditions at any time without prior notice. In the event that any revisions are made, the revised terms and conditions shall be posted on our website immediately, please visit our website to inform yourself of any changes.
WARNING
1 Do not place the device near heat source, such as a fire or a heating furnace. 2 Do not immerse in any liquid, or expose the unit to rain or wet conditions. 3 Do not use the battery in a strong static electricity or electromagnetic environment. 4 Do not disassemble or puncture the product with sharp objects in any way. 5 Short circuits can be caused by: vermin or pests chewing through wires; water or other fluids coming into contact
with electrical wiring. 6 It’s prohibited to be used as car jump starter, only can be used to charge the car battery. 7 Do not use accessories or parts other than those provided by PECRON. Please visit our website www.pecron.com or
reach our support team for a complete list of accessories and parts.
support@pecron.com
8 When using this product, please strictly follow the ambient temperature for use in the user manual. If the temperature is too high, the battery can potentially result in self-combustion and will burst into flames, which can cause widespread damage. If the temperature is too low, the performance of the battery will be seriously degraded, and it may even fail to meet the normal use requirements.
9 Do not stack heavy objects on this product. 10Do not block the air vents during use, or leave the device in a non-ventilated or dusty space. 11Please avoid impacts, fall off, and violent vibration. Please turn off the device immediately and stop using it in the
event of major exterior impact. Please fasten the unit firmly during transportation to avoid vibration and impact. 12In the event of immersing the device into the water accidently, please place the unit in a safe open area and keep
away from the unit until it is completely dry. The dried unit should not be reused and should be disposed of properly according to the local regulation. If the device catches fire, use the fire extinguishing equipment in the following recommended order: water or mist, sand, fire blanket, dry chemical, carbon dioxide fire extinguisher. 13Please wipe it with a dry cloth to clean the surface of the device. 14Please place this device with care to prevent the product from being damaged due to fall off. If the product is damaged due to fall off, please turn off the unit immediately and place it in an open area, keep away from combustibles and crowds, and dispose of in accordance with local laws and regulations. 15Please store this device in a place out of reach of children and pets.
support@pecron.com
DISPOSAL
1When conditions permit, please be sure to completely discharge the battery of this product, and then put the product in the designated battery recycling box. This product contains batteries. Batteries are dangerous chemicals and are strictly prohibited from being disposed of in ordinary trash. For details, please follow local laws and regulations on battery recycling and disposal.
2If the battery cannot be completely discharged due to the failure of the product itself, please do not dispose of the battery directly in the battery recycling box, and contact a professional battery recycling company for further disposal.
3The battery will not be able to start after being over-discharged, please dispose of it according to the principle of disposal.
EXCLUSIONS
PECRON’s warranty does not apply to Misused, abused, modified, damaged by accident, or used for anything other than normal consumer use as authorized in PECRON’s current product literature.
NEED HELP? WE’RE HERE FOR YOU!
WEBSITEwww.pecron.com Customer Supportsupport@pecron.com Call Us: +1 888 906 5997 ( 9am -5pm EST, Mon. -Fri.) Please note your order number and platform of purchase, so we can quickly help you check the order info and solve it. PECRON thank you for your support and cooperation!
support@pecron.com
POWER IT POSSIBLE
www.pecron.com
support@pecron.com
Documents / Resources
![]() |
pecron E600 LFP Expandable Portable Power [pdf] User Manual V3, E600 LFP Expandable Portable Power, E600 LFP, Expandable Portable Power, Portable Power, Power |