Instructions
WIRING INFORMATION
- TURN OFF POWER.
- LOOSEN TERMINAL SCREWS.
- CONNECT WITH INSULATED COPPER CONDUCTORS (SOLID OR STRANDED). DO NOT TIN CONDUCTORS.
CAUTION:USE WITH COPPER WIRE ONLY.
ATTENTION:EMPLOYER UNIQUEMENT AVEC FIL DE CUIVRE. - DO NOT EXCEED MARKED ELECTRICAL RATING.
- FOR PROPER WIRING PROCEDURE.
A. FOR BACK WIRED DEVICES, SEE FIG. A
a) STRIP WIRE(* 14-710 AWG)11/116 LONG.
b) INSERT STRIPPED WIRE IN BACK SLOT UNDER CLAMP.
B. FOR SIDE WIRED DEVICES, SEE FIG. B
a) STRIP WIRE(’ 14-°10 AWG)15/16 LONG.
b) BEND WIRE AROUND SCREW. - TIGHTEN SCREWS TO 12-15 INCH POUNDS.
NOTE: WHEN FLUORESCENT LOADS ARE CONTROLLED BY LIGHTED SWITCHES THE LAMP MAY OCCASIONALLY FLICKER WHEN THE SWITCH IS IN THE OFF POSITION. - AGREEN HEX, HEAD SCREW (OR GREEN PIG TAIL) IS PROVIDED TO GROUND THE MOUNTING STRAP WHERE REQUIRED.
- INSTALL SWITCH AND WALL PLATE SECURELY TO ELECTRICAL BOX.
- TURN ON POWER.