PARADOX ZX8SP 8 Zone Expansion Module
Product Information
The ZX8SP 8-Zone Expansion Module V5.0 serves as an interface between the control panel and hardwired detection devices. It provides eight additional hardwired inputs and one 50 mA on-board PGM output. Please note that the ZX8SP does not support ATZ or fire zone connections.
Specifications
- Input voltage: Typically 12 to 16 Vdc
- Current consumption: 28 mA
- Maximum number of ZX8SP: 3
- Number of outputs: 1
- Number of zones: 8
- Operation temperature: Not specified
Installation
- Connect the ZX8SP to the control panel’s combus.
- Ensure proper power supply within the specified input voltage range.
- Connect the hardwired detection devices to the ZX8SP input terminals according to the control panel’s Programming Guide.
Jumper Settings
To change jumper settings, press the Disable Locate button located on the module. Use the provided guide to set jumpers based on your panel configuration.
Output Configuration
The on-board PGM output provides a maximum of 50 mA. If more current is needed, use a 12 Vdc relay.
Anti-Tamper Switch
Input terminal Z1 can be utilized as an anti-tamper switch input.
The 8-Zone Expansion Module (ZX8SP) is an interface between the control panel and any hardwired detection devices. The ZX8SP connects to the control panel’s combus to provide eight additional hardwired inputs and one 50 mA on-board PGM output. The ZX8SP does not support ATZ or fire zone connections.
Compatibility
- All Spectra SP Series Control Panels
- MG5000 / MG5050 Control Panels
Specifications
Input voltage | Typically 12 to 16 Vdc |
Current consumption | 28 mA |
Maximum number of ZX8SP | Maximum 3 |
Number of outputs | One 50 mA PGM |
Number of zones | 8 standard zone inputs |
Operation temperature | -20ºC to 50ºC (-4ºF to 122ºF)
UL tested to 0ºC to 49ºC (32ºF to 120ºF) |
Anti-Tamper Switch
Input terminal Z1 can be used as an anti-tamper switch input.SP Series / MG5000 / MG5050
Enable section [706] option [4] for panel+1,option [5] for panel+9 and option [6] for panel+17.
Jumper Settings
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement found on our website paradox.com/terms or contact your local distributor. Specifications may change without
prior notice.
Patents
© 2004-2019 Paradox Security Systems (Bahamas) Ltd. All rights reserved. US, Canadian and international patents may apply. SP Series and Paradox are trademarks or registered trademarks of Paradox Security Systems (Bahamas) Ltd.
© 2004–2019 Paradox Security Systems (Bahamas) Ltd. Todos los derechos reservados. Pueden aplicarse patentes estadounidenses, canadienses e internacionales.
FAQ
Q: Can the ZX8SP be used for fire zone connections?
A: No, the ZX8SP does not support fire zone connections.
Q: How many hardwired inputs does the ZX8SP provide?
A: The ZX8SP offers eight additional hardwired inputs.