CMS101 Multimeters Mobile and Desktop
Product Information
Specifications:
- Warranty: 1 year from the date of purchase
- Defect Coverage: Materials and workmanship
- Service: Repair or replacement for defective products
Product Usage Instructions
Warranty Information:
The product is warranted to be free from defects for 1 year from
the date of purchase by the original buyer. The warranty covers
repair or replacement of defective parts or products.
Obtaining Warranty Service:
To obtain service under warranty, the customer must notify the
company of the defect before the warranty period expires. The
customer is responsible for packaging and shipping the defective
product to the designated service center along with proof of
purchase.
Limitations of Warranty:
The warranty does not cover defects caused by improper use,
inadequate maintenance, or care. After-sales services are available
at Sales and Service Offices.
Illustrations and Actual Product:
Illustrations, icons, and characters in the user manual may
differ slightly from the actual product. Please refer to the
product for accurate details.
FAQ
Q: What is the warranty period for the product?
A: The product is covered under warranty for 1 year from the
date of purchase by the original buyer.
Q: How can I obtain warranty service?
A: To obtain warranty service, you must notify the company of
the defect before the warranty period expires. Please package and
ship the defective product to the designated service center along
with proof of purchase.
General Warranty
We warrant that the product will be free from defects in materials and workmanship for a period of 1 years from the date of purchase of the product by the original purchaser from our company. This warranty only applies to the original purchaser and is not transferable to a third party.
If the product proves defective during the warranty period, we will either repair the defective product without charge for parts and labour, or will provide a replacement in exchange for the defective product. Parts, modules, and replacement products used by our company for warranty work may be new or reconditioned like new. All replaced parts, modules and products become the property of our company.
In order to obtain service under this warranty, the customer must notify our company of the defect before the expiration of the warranty period. Customer shall be responsible for packaging and shipping the defective product to the designated service centre, a copy of the customers proof of purchase is also required.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care.
We shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than our company representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of not our supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
Please contact the nearest Sales and Service Offices for services.
Excepting the after-sales services provided in this summary or the applicable warranty statements, we will not offer any guarantee for maintenance declared or hinted, including but not limited to the implied guarantee for marketability and special-purpose acceptability. We should not take any responsibilities for any indirect, special, or consequent damages.
The illustrations, interface, icons and characters in the user manual may be slightly
different from the actual product. Please refer to the actual product.
Table of Contents
1.Safety Information ……………………………………………………………………1
General Safety Requirements ………………………………………………………………………………….. 1 Measurement Category ……………………………………………………………………………………………. 3 Safety Terms and Symbols ………………………………………………………………………………………..3
2.Quick Start ……………………………………………………………………………… 5
General Inspection …………………………………………………………………………………………………….5 Install the Battery ……………………………………………………………………………………………………… 5 Power on/off ……………………………………………………………………………………………………………… 6 Selecting the Range …………………………………………………………………………………………………. 6 Instrument Panel ………………………………………………………………………………………………………. 7
Front Panel and Keys …………………………………………………………………………………………7 Instrument Interface …………………………………………………………………………………………………..9
Multimeter interface …………………………………………………………………………………………… 9 Oscilloscope interface ……………………………………………………………………………………… 10 How to Connect with Android Device ……………………………………………………………………… 11
3.Appendix ………………………………………………………………………………. 14
Appendix A: List of Accessories ……………………………………………………………………………… 14 Appendix B: Maintenance and Cleaning ………………………………………………………………….14
General maintenance ……………………………………………………………………………………….14 Charging and Replacement of Battery ……………………………………………………………..15 Replacement of Lithium Battery ………………………………………………………………………. 15
i
1.Safety Information
1.Safety Information
Be sure to read the safety information before using this product.
General Safety Requirements
Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage. In order to avoid any contingent danger, this product is only used within the range specified. Limit operation to the specified measurement category, voltage, or amperage ratings. Do not use the digital clamp meter if it is damaged. Before you use the digital clamp meter, inspect the case. Look for cracks or missing plastic. Pay particular attention to the insulation surrounding the connectors. Do not use the test leads provided for other products. Use only the certified test leads specified for this product. Inspect the test leads for damaged insulation or exposed metal. Before use, verify the digital clamp meter’s operation by measuring a known voltage. Only the qualified technicians can implement the maintenance. Always use the specified battery type. The power for the digital clamp meter is supplied with a battery. Observe the correct polarity markings before you insert the batteries to ensure proper insertion of the batteries in the digital clamp meter. Check all Terminal Ratings. To avoid fire or shock hazard, check all ratings and markers of this product. Refer to the user’s manual for more information about ratings before connecting to the digital clamp meter. Do not operate the digital clamp meter with the cover or portions of the cover removed or loosened. Do not operate if in any doubt. If you suspect damage occurs to the digital clamp meter, have it inspected by qualified service personnel before further operations. Do not operate this product in wet or damp conditions.
1
1.Safety Information
Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. Do not apply more than the rated voltage (as marked on the digital clamp
meter) between terminals, or between terminal and earth ground. When measuring current, turn off the circuit power before connecting the
digital clamp meter in the circuit. Remember to place the digital clamp meter in series with the circuit. When servicing the digital clamp meter, use only the specified replacement parts. Use caution when working above 60 V DC, 30 V AC RMS, or 42.4 V peak. Such voltages pose a shock hazard. When using the test leads, keep your fingers behind the finger guards on the test leads. Remove the test leads from the digital clamp meter before you open the battery cover. To avoid false readings, which may lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator appears and flashes. Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. Use the proper terminals, function, and range for your measurements. When the range of the value to be measured is unknown, set the rotary switch position as the highest range, or choose the auto ranging mode. To avoid damages to the digital clamp meter, do not exceed the maximum limits of the input values shown in the technical specification tables. Connect the common test lead before you connect the live test lead. When you disconnect the leads, disconnect the live test lead first. Before changing functions, disconnect the test leads from the circuit under test.
2
1.Safety Information
Measurement Category
The digital clamp meter has a safety rating of 1000 V,CAT III and 600V,CAT IV.
Measurement category definition
Measurement CAT I applies to measurements performed on circuits not directly connected to the AC mains. Examples are measurements on circuits not derived from the AC mains and specially protected (internal) mainsderived circuits.
Measurement CAT II applies to protect against transients from energy-consuming equipment supplied from the fixed installation, such as TVs, PCs, portable tools, and other household circuits.
Measurement CAT III applies to protect against transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings.
Measurement CAT IV applies to measurements performed at the source of the low-voltage installation. Examples are electricity meters and measurements on primary over current protection devices and ripple control units.
Safety Terms and Symbols
Safety Terms
Terms in this Manual. The following terms may appear in this manual:
Warning: Warning indicates the conditions or practices that could result in personal injury or death.
Caution: Caution indicates the conditions or practices that could result in damage to this product or other property.
Terms on the Product. The following terms may appear on this product: Danger: It indicates an injury or hazard may immediately happen.
3
1.Safety Information
Warning: It indicates an injury or hazard may be accessible potentially.
Caution: It indicates a potential damage to the instrument or other property might occur.
Safety Symbols
Symbols on the Product. The following symbol may appear on the product:
Direct current (DC) Alternating current (AC) Both direct and alternating current
Fuse Caution, risk of danger (refer to this manual for specific Warning or Caution information) Category I overvoltage protection
Ground terminal
Category II overvoltage protection
Conforms to European Union directives Equipment protected throughout by double insulation or reinforced insulation
Category III overvoltage protection Category IV overvoltage protection
4
2.Quick Start
2.Quick Start
General Inspection
After you get a new digital clamp meter, make a check on the instrument according to the following steps:
1. Check whether there is any damage caused by transportation. If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage, do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests.
2. Check the Accessories The supplied accessories have been already described in the Appendix A: Enclosure of this Manual. You can check whether there is any loss of accessories with reference to this description. If it is found that there is any accessory lost or damaged, please get in touch with our distributor responsible for this service or our local offices.
3. Check the Complete Instrument
If it is found that there is damage to the appearance of the instrument, or
the instrument can not work normally, or fails in the performance test,
please get in touch with our distributor responsible for this business or our
local offices. If there is damage to the instrument caused by the
transportation, please keep the package. With the transportation
department or our distributor responsible for this business informed about
it, a repairing or replacement of the instrument will be arranged by us.
Install the Battery
The digital clamp meter is powered by a 3.7V (18650) battery.
Warning: To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator appears. Before replacing the battery, turn off the meter, disconnect test leads and any connectors from any circuit under test, remove test leads from the input terminals. Use only the specified
5
2.Quick Start
battery type.
Use the following procedure to install the battery (1) Power off, remove test leads and any connectors from the input
terminals. (2) Loosen the screws with a suitable Phillips screwdriver and remove the
battery cover. (3) Observe the battery polarity indicated inside the battery compartment,
Insert the battery. (4) Place the battery cover back in its original position and tighten the
screws.
Caution: To avoid instruments being damage from battery leakage, remove the batteries and store them separately if the digital clamp meter is not going to be used for a long period.
Power on/off
It can be turned on in the following ways:
Press the
button at the bottom left of the host;
It can be turned off in the following ways:
Manual shutdown,tap and hold
button;
Automatic shutdown, emit a short beep one minute before shutdown, emit a long beep during shutdown;
Low power automatic shutdown.
Selecting the Range
Auto ranging is set as default when the meter is powered on, Auto is displayed.
Under automatic range, press
or
to enter the manual range
mode.
Under manual range, each additional press of
sets the next higher
range; each additional press of
sets the next lower range.
Under manual range, press to enter the auto range mode.
Note:Manual range is not available when measuring capacitance,only in multimeter measurement mode.
6
Instrument Panel
2.Quick Start
Front Panel and Keys
Figure 2- 1Front panel
Description:
Num Illustration in multimeter mode
1
NCV measurement.
2
Safety level.
Illustration in oscilloscope mode
7
2.Quick Start
3
Maximum current allowed to be measured.
4
Operation indicator light.
5
Reading hold button.
Run/Stop button.
6
Display area.
7
The F1 – F4 keys are multi-function keys. In each menu mode, press
the corresponding key to select the corresponding menu item.
8
Function of direction keys
Function of direction keys
: used for changing range.
: used for the voltage or
Function of key:Restore
current scales.
auto gear.
Function of direction keys
:
used for zooming waveforms and
the time base changing.
Function of key: Perform
automatic setup.
9
Measurement input port: the input of the measurement signal.
10 Charging port.
11 Switch key for working state of oscilloscope and multimeter. Press the
power button briefly to turn on the device. After powering on, press
briefly to switch to the oscilloscope or multimeter mode. Press and hold
to turn off the device.
12 Tab function switch button.
13 Clamp head trigger: Press the trigger to open the clamp heads; release
the trigger, and the clamp heads will automatically close.
14 Clamp head: The current measurement sensor converts alternating or
direct current into voltage.
8
2.Quick Start
Instrument Interface Multimeter interface
Description: 1. Measurement type indication:
Measurement type Description
A,DC
DC current measurement
A,AC
AC current measurement
V,DCmV,DC
DC voltage measurement
V,ACmV,AC
AC voltage measurement
Res
Resistance measurement
Cont
On/Off measurement
Diode
Diode measurement
Cap
Capacitance measurement
Freq
Frequency measurement
NCV
Non-contact AC voltage sensing
2. Range indication: Manu means manual range; Auto means automatic
range.
9
2.Quick Start 3. Current measurement range. 4. Automatic shutdown sign: Display the flag when enabled. Closing will hide
the identity. 5. Bluetooth sign: Display the flag when enabled. Closing will hide the
identity. 6. Battery power and external power supply indication. 7. Inrush mode (Only in ACA mode). 8. Reading hold mode. 9. Current measurement menu. 10. Current measurement unit 11. DC/AC/On-Off/Diode/Capacitance mode. 12. Range simulation strip. 13. Operation menu.
Oscilloscope interface
Description: 1. Time base display (In the horizontal direction, each grid represents a
specific time interval.). 10
2.Quick Start
2. Scale (In the vertical direction, each grid represents a specific voltage or current value.)
3. The trigger status indicates the following information: TrigA trigger has been detected and post trigger information is being collected. Ready:All pre trigger data have been obtained and the oscilloscope is ready. Scan:Continuously collect and display waveform data. Stop:Stop collecting waveform data.
4. Automatic shutdown sign: Displays the flag when enabled. Closing will hide the identity.
5. Bluetooth sign: Displays the flag when enabled. Closing will hide the identity.
6. Battery power and external power supply indication. 7. Rms value. 8. Trigger horizontal displacement. 9. Trigger level position. 10. Measurement value. 11. Operation menu. 12. Waveform display area. 13. Channel waveforms. 14. Frequency value.
How to Connect with Android Device
(1) On the mobile device, scan the QR code below and follow the instructions to install the free multimeter app.
11
2.Quick Start
(2) Open the installed application on your mobile device.
(3) Turn on the multimeter, press and hold
until
display. (4) Click on “Device List” in the bottom navigation bar.
appear on the
(5) Click the “+” icon in the upper left corner to begin searching for devices and list out the multimeters found.
(6) If the Bluetooth of the mobile device is not enabled, a prompt box will pop up at the bottom, indicating “Bluetooth is not turned on”. You need to manually open the Bluetooth of the mobile device before connection can be made.
(7) Active “Filter device” to hide incompatible multimeters. 12
2.Quick Start (8) After “BDM” appears in the list of available devices, click and select to
connect it to the mobile device. Note: When Bluetooth is enabled, the auto power-off function is disabled. After Bluetooth is turned off, the auto power-off function will be restored.
13
3.Appendix
3.Appendix
Appendix A: List of Accessories
1 set of probes 1 quick guide 1 USB-TYPE C line
Appendix B: Maintenance and Cleaning
General maintenance
Do not store or place the instrument in a place where the LCD screen will be exposed to direct sunlight for a long time. Caution: Do not let spray, liquid or solvent touch the instrument or probe to prevent damage to the instrument or probe. Cleaning: Check the instrument and probe frequently according to the operation. Clean the external surface of the instrument as follows: 1. Please wipe the floating dust outside the instrument and probe with a soft cloth. When cleaning the LCD, be careful not to scratch the transparent LCD protection screen. 2. Wipe the instrument with a damp but non dripping soft cloth. Please disconnect the power supply. It can be scrubbed with soft detergent or water. Do not use any abrasive chemical cleaning agent to avoid damaging the instrument or probe.
Warning: Please make sure the instrument is dry before re-energizing to avoid electrical short circuit or personal injury caused by moisture.
14
3.Appendix
Charging and Replacement of Battery
During the long-term storage of the device, the battery may be too low due to the self-discharge of the lithium battery and the device cannot be turned on. T his is a normal phenomenon. Please use the attached adapter to pre-charge the device for 0.5 to 1 hour ( depending on the storage time) before turning it on. In addition, if the device is not used for a long time, it is recommended to charge it at regular intervals to avoid over-discharge of the lithium battery.
Battery Charging The lithium battery may not be fully charged when delivered. To make the battery be charged,this device has an approximate charging time of 8 hours and a peak discharge battery life of about 18.5 hours.The power supply and battery indicator symbols in the upper right corner of the screen are explained as follows: symbol indicates the power-on charging status; symbol indicates battery power supply; symbol indicates that there is only about five minutes of use time left.
Please charge as soon as possible according to the relevant tips to avoid damage to the battery.
Charging Method
Connect the digital clamp meter to a computer or other equipment through a USB data cable for charging (pay attention to the load capacity of the power supply equipment to avoid abnormal operation of the equipment). Note
To avoid overheating of the battery during charging, the ambient temperature must not exceed the allowable value given in the technical specifications.
Replacement of Lithium Battery
Generally, the battery does not need to be replaced. However, when necessary, it can only be replaced by qualified personnel, and only lithium batteries of the same specification can be used.
V1.0.1
15
Documents / Resources
![]() |