OVATIONREVEP - logo3IP Multi Color Full Spectrum
User Manual

OVATIONREVEP3IP Multi Color Full Spectrum

OVATIONREVEP3IP Multi Color Full Spectrum

Edition Notes
The Ovation Rêve P-3 IP User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the Ovation Rêve P-3 IP as of the release date of this edition.
Trademarks
Chauvet, Chauvet Professional, the Chauvet logo, Ovation, and Ovation Rêve are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
Copyright Notice
The works of authorship contained in this manual, including, but not limited to, all designs, text, and images are owned by Chauvet.
© Copyright 2024 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America.
Manual Use
Chauvet authorizes its customers to download and print this manual for professional information purposes only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this manual or its content for any other purpose without written consent from Chauvet.
Document Printing
For best results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. If using A4 paper (210 x 297 mm), configure the printer to scale the content accordingly.
Intended Audience
Any person installing, operating, and/or maintaining this product should completely read through the guide that shipped with the product, as well as this manual, before installing, operating, or maintaining this product.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision,  owever,
Chauvet has no obligation to make, and does not commit to make, any such revisions.
Document Revision
Go to www.chauvetprofessional.com for the latest version.

Revision Date Description
4 1/2024 Updated What’s included section

Before You Begin

What Is Included

  • Ovation Rêve P-3 IP
  • Seetronic Powerkon IP65 power cable
  • Narrow, Medium, Wide, and Very Wide lenses
  • Gel frame
  • Omega bracket with mounting hardware
  • Quick Reference Guide

Claims
Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate a claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.
Text Conventions

Convention Meaning
1–512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
<ENTER> A key to be pressed on the product’s control panel

Symbols

Symbol Meaning
warning 2 Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
Paulmann Ceiling Lighting Accessories - Icon 1 Important installation or configuration information. The product may not function correctly if this information is not used.
OVATIONREVEP3IP Multi Color Full Spectrum - icon Useful information.

warning 2 Any reference to data or power connections in this manual assumes the use of Seetronic IP-rated cables.
OVATIONREVEP3IP Multi Color Full Spectrum - icon The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol.

Safety Notes

Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product.
warning 2 This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs.
Paulmann Ceiling Lighting Accessories - Icon 1 All applicable local codes and regulations apply to proper installation of this product.

  • The luminaire is intended for professional use only.
  • The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 3.3 ft (1 m) is not expected.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or its service agent.
  •  The light source contained in this luminaire shall only be replaced by the manufacturer or its service agent or a similar qualified person.
  • CAUTION:
  • This product’s housing may be hot when operating. Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
  • Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding notification of strobe use.
  • ALWAYS:
  • Disconnect from power before cleaning the product or replacing the fuse.
  • When using an IP65-rated product in an outdoor environment, use IP65- (or higher) rated power and data cable.
  • Replace and secure IP-rated protective covers to all power, data, USB, or other ports when not in use.
  • Replace the fuse with the same type and rating.
  • Use a safety cable when mounting this product overhead.
  • Connect this product to a grounded and protected circuit.
  • DO NOT:
  • Open this product. It contains no user-serviceable parts.
  • Look at the light source when the product is on.
  • Leave any flammable material within 20 cm of this product while operating or connected to power.
  • Connect this product to a dimmer or rheostat.
  • Operate this product if the housing, lenses, or cables appear damaged.
  • Submerge this product (adhere to standards for the published IP rating). Regular outdoor operation is fine.
  • Permanently install outdoors in locations with extreme environmental conditions. This includes, but is not limited to:
  • Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
  • Locations where normal temperatures exceed the temperature ranges in this manual.
  • Locations that are prone to flooding or being buried in snow.
  • Other areas where the product will be subject to extreme radiation or caustic substances.
  • ONLY use the handles or the hanging/mounting brackets to carry this product.
  • The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
  • The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
  • The minimum ambient temperature is -22°F (-30°C). Do not operate the product at lower temperatures.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • In the event of a serious operating problem, stop using immediately.

OVATIONREVEP3IP Multi Color Full Spectrum - icon If a Chauvet product requires service, contact Chauvet Technical Support.
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Expected LED Lifespan
Over time, use and heat will gradually reduce LED brightness. Clustered LEDs produce more heat than single LEDs, contributing to shorter lifespans if always used at full intensity. The average LED lifespan is 40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit the overall intensity.

Introduction

Description
The Ovation Rêve P-3 IP is the brightest IP65-rated multi-color full-spectrum-white LED PAR. An outdoor fixture with unsurpassed power and quality of light that incorporates all the advancements of our Ovation Rêve RGBAM LED source, and offers the versatility of Narrow, Medium, Wide and Very Wide lenses.
Linear color temperature presets from 2800 K to 8000 K with high CRI and CQS. Adjustable PWM (Pulse Width Modulation) avoids on camera flicker. Indoors or out, a powerful instrument for theatrical, house of worship, special events, rental and production use.
Features

  • Full-spectrum LED PAR lighting fixture for rental/production use as well as special event and theatre.
  • Fully IP65 rated for seasonal use indoors or out
  • Interchangeable Narrow, Medium, Wide, and Very Wide lenses.
  • USB port for fixture software updates
  • Linear color temperature presets from 2800 K to 8000 K with high CRI and CQS
  • +/- Green adjustment and emulated red-shift via DMX or on-board control

Product Overview

OVATIONREVEP3IP Multi Color Full Spectrum - fig

# Name
1 LCD display
2 DMX in
3 Power in
4 Fuse holder
5 Power out
6 DMX out
7 Menu buttons
8 USB C port

Product DimensionsOVATIONREVEP3IP Multi Color Full Spectrum - fig 1

Setup

AC Power
The Ovation Rêve P-3 IP has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under normal conditions.

  • Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
  • warning 2 To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Paulmann Ceiling Lighting Accessories - Icon 1 Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Ovation Rêve P-3 IP comes with a power input cable terminated with a Seetronic Powerkon A connector on one end and an Edison plug on the other end (U.S. market). If the cable has no plug or it is necessary to change the plug, use the table below to wire a plug.

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow or Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green

Fuse Replacement

  1. Disconnect this product from the power outlet.
  2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
  3. Remove the blown fuse and replace with another of the same type and rating (T 6.3 A, 250 V).
  4. Screw the fuse holder cap back in place and reconnect power.

Power Linking
It is possible to power link Ovation Rêve P-3 IP products. See the table below for the current draw at each voltage and frequency:

100 V, 60 Hz 120 V, 60 Hz 208 V, 60 Hz 230 V, 50 Hz 240 V, 50 Hz
Current Draw 2.78 A 2.31 A 1.38 A 1.25 A 1.22 A

DMX Linking
The Ovation Rêve P-3 IP can be linked to a DMX controller using a 3-pin or 5-pin DMX connection. If using other DMX-compatible products with this product, it’s possible to control each individually with a single DMX controller.
DMX Personalities
The Ovation Rêve P-3 IP uses a 3-pin or 5-pin DMX data connection for the 1 Ch, 4 Ch, 5 Ch, 7 Ch, 11 Ch, 13 Ch1, 13 Ch2, 17 Ch, and HSV DMX personalities.

  • Refer to the Operation chapter to learn how to configure the Ovation Rêve P-3 IP to work in these personalities.
  • The DMX Channel Assignments and Values section provides detailed information regarding the DMX personalities.

OVATIONREVEP3IP Multi Color Full Spectrum - icon For information about DMX standards, Master/Slave connectivity, or the DMX cables needed to link this product to a DMX controller, download the DMX Primer from the Chauvet website: www.chauvetprofessional.com.
Remote Device Management
Remote Device Management (RDM) is a standard for allowing DMX-enabled devices to communicate bi- directionally along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers have this capability. The Ovation Rêve P-3 IP supports RDM protocol that allows feedback to make changes to menu map options. Master/Slave Connectivity
The Master/Slave mode allows an Ovation Rêve P-3 IP (the master) to control one or more Ovation Rêve P-3 IP products (the slaves) without a DMX controller. Once Ovation Rêve P-3 IP becomes the master when running an auto or custom program, or in Static mode.
Each slave’s control panel must be configured to operate in Slave mode. During Master/Slave operation, the slaves will operate in unison with the master
Paulmann Ceiling Lighting Accessories - Icon 1 DO NOT connect a DMX controller to products operating in Master/Slave mode. The DMX controller signals may interfere with the signals from the master.

  • The Operation section of this manual provides detailed instructions on how to configure the master and slaves.
  • For more information about DMX standards or the DMX cables needed to link this product to a DMX controller, download the DMX primer from the Chauvet website: www.chauvetprofessional.com.

USB Software Update
The Ovation Rêve P-3 IP allows for software update through USB using the built-in USB port. To update the software using a USB flash drive, do the following:

  1. Power on the product and plug the flash drive into the USB port.
  2. Once the flash drive has been detected, the message “Upgrade?” will be displayed. Select “YES” and Press <ENTER>. A list of the updated software files will be displayed.
    warning 2  If no valid firmware file is detected in the USB, the screen will display “No File”.
  3. Select the file that needs to be uploaded.
    • Be sure to select the correct file before pressing <ENTER>. DO NOT turn off the power or disconnect the USB during the process. The USB update can take several minutes to complete.
  4. When the update is complete, the product will automatically reboot.
  5. Go to the Fixture Information level of the product main menu and confirm the firmware revision.
  6. When the boot-up process is finished, restart the product manually.
    • Place the .chl file in the root directory of the USB drive.
    OVATIONREVEP3IP Multi Color Full Spectrum - icon The product’s USB port supports up to 32GB capacity and only works with FAT32 file format.

warning 2 Turning off the power, removing the USB, or not setting the fixture to the correct protocol during the update can cause partial or total firmware failure in the targeted fixture(s). Please refer to the Upload 01 Instructions to fix firmware failure issues.
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
Orientation
Always mount this product in a safe position, making sure there is adequate room for ventilation, configuration, and maintenance.
Rigging
Chauvet recommends using the following general guidelines when mounting this product.

  • Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
  • Make sure that the structure and attachment points can support the weight before hanging the product (see the Technical Specifications).
  • When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, whether an elevated platform or a truss.
  • When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.

Procedure
The Ovation Rêve P-3 IP comes with an omega bracket. The user can directly attach a mounting clamp (sold separately) to that bracket. Make sure the clamp is capable of supporting the weight of this product.
For the Chauvet Professional line of mounting clamps, go to http://www.trusst.com/products.
Mounting DiagramOVATIONREVEP3IP Multi Color Full Spectrum - fig 2Changing the Lens
The Ovation Rêve P-3 IP comes with 4 interchangeable lenses with different beam angles (Narrow, Medium, Wide, and Very Wide lenses).
To change the lens:

  1. Push and hold the locking tab out from the product.
  2. Pull the installed lens out by the flap.
  3. Insert the desired lens and release the locking tab.

OVATIONREVEP3IP Multi Color Full Spectrum - fig 3

Operation

Control Panel Description

Button Function
<MENU> Exits from the current menu or function
<ENTER> Enables the currently displayed menu or sets the selected value into the function
<UP> Navigates upwards through the menu list or increases the numeric value when in a function
<DOWN> Navigates downwards through the menu list or decreases the value when in a function
<FOCUS> Sets fixture into Focus Mode, which takes the unit to full power for easy focusing without changing any other fixture settings. Press again to release from Focus Mode.

Menu Map
Refer to the Ovation Rêve P-3 IP product page on www.chauvetprofessional.com for the latest menu map.

Main Level Programming Levels Description
DMX Address 001–512* Selects DMX address (*highest channel restricted to personality chosen)
DMX Channel 1Ch VCW 1-channel: dimmer
CCT
Manual
4Ch 4-channel: dimmer, VCW, CCT, hue
5Ch 5-channel: RGBAL
7Ch 7-channel: dimmer, RGBAL, strobe
11Ch 11-channel: 16-bit dimmer, RGBAL, strobe, VCW, CCT, hue
13Ch1 13-channel: dimmer, RGBAL, strobe, VCW, CCT, hue, auto program, auto speed, control
13Ch2 13-channel: 16-bit dimmer, 16-bit RGBAL, strobe
17Ch 17-channel: 16-bit dimmer, 16-bit RGBAL, strobe, VCW, CCT, hue, control
HSV 3-channel: hue, saturation, value
Virtual Color VCW Md Yellow Dimmer 0–255 Virtual Color Wheel simulates the output of each gel color. Refer to the Virtual Color Wheel Chart for specific values.
Lt Yellow
Amb Yellow
VLt Amber
Lt Amber
Md Amber
Dk Amber
Lt Red
Md Red
NC Pink
Md Pink
Dk Pink
Md Red Amber
Dk Red Amber
Magenta
Dk Magenta
Lt Lavender
Lt Blue
VLt Blue
Lt Blue 2
Main Level Programming Levels Description
Virtual Color (cont.) VCW (cont.) Blue Dimmer 0–255 Virtual Color Wheel simulates the output of each gel color. Refer to the Virtual Color Wheel Chart for specific values.
Md Blue
Dk Blue
Indigo
VDk Blue
VDk Blue 2
Yel Green
Green
Turquoise
Aqua
Blue Green
CCT 2800K Dimmer 0–255 Hue 25–25 Preset white color temperatures. Emulates a tungsten lamp at the specified color temperature. Refer to the Color Temperature Chart for specific values.
2900K
3000K
3100K
3200K
3300K
3400K
3500K
3600K
3700K
3800K
3900K
4000K
4100K
4200K
4300K
4400K
4500K
4600K
4700K
4800K
4900K
5000K
5100K
5200K
5300K
5400K
5500K
5600K
5700K
6000K
6500K
7000K
7500K
8000K
Main Level Programming Levels Description
Virtual Color (cont.) Manual Red 0–255 Combines red, green, blue, amber, and mint to make a custom color (0–100%)
Green
Blue
Amber
Mint
Color X-Fade Speed Off Disables fade transition between colors
Fade Speed 1  

Enables fade transition between colors in the Virtual Color Wheel menu, from fast (X-Fade Speed 1) to slow (X-Fade Speed 4)

Fade Speed 2
Fade Speed 3
Fade Speed 4
Auto Show Auto 1–5 Speed 1–100 Selects automatic programs and auto program speed
Red Shift On Mimics halogen lamp dimming
Off
Master/ Slave Master Receives DMX signal from the DMX controller (master)
Slave Receives DMX signal from the master unit
Dimmer Curve SCurve Sets the dimmer curve
Linear
Square
Inverse Square
Dimmer Mode Off Linear dimmer
Dimmer 1–3 Dimming curves, from fast (Dimmer 1) to slow (Dimmer 3)
Color Calib Off Uncalibrated LED maximum values
User Calib Red 125–255 Sets red LED maximum value
Green Sets green LED maximum value
Blue Sets blue LED maximum value
Amber Sets amber LED maximum value
Mint Sets mint LED maximum value
Factory Calib Uses factory default white setting
LED Frequency 600Hz Sets the PWM frequency
1200Hz
2000Hz
4000Hz
6000Hz
25KHz
Fan Mode Auto Sets the fan to auto mode
On Sets the fan to always on
Off Sets the fan to always off
Silent Sets the fan to silent
Back Light 10S Turns off display backlight after 10 seconds
30S Turns off display backlight after 30 seconds
2Min Turns off display backlight after 2 minutes
Always On Display backlight remains on
Main Level Programming Levels Description
Information Fixture Hours _ _ _ _Hours _ _Minute Shows total hours the product has been powered on
LED Hours _ _ _ _Hours _ _Minute Shows total hours the LEDs have been powered on
Version V_._ _ _ _ _ _ Shows current firmware version
UID _ _ _ _ _ _ _ _ _ _ _ _ _ _ Shows product UID
Upgrade  

Only This Fixture

_ _ _ _ _ _.CHL Selects an update file for this product, or shows “No such file!
Multiple Fixture _ _ _ _ _ _.CHL Selects an update file for this and connected Ovation Rêve P-3 IP products, or shows “No such file!
 

Other Fixture Type

_ _ _ _ _ _.CHL Selects an update file for other connected products, or shows “No such file!
Factory Reset No Resets settings to factory default
Yes

warning 2 When operating in Fan Mode: Off and Fan Mode: Silent, the fixture will become hotter to the touch than when using other fan modes. Use proper protective equipment to prevent urns. Keep a safe distance from flammable objects.
Paulmann Ceiling Lighting Accessories - Icon 1 When operating in Fan Mode: Off and Fan Mode: Silent, output of the fixture will be reduced and will not reach the same levels as when using other fan modes.
DMX Configuration
Use control configurations to operate the product with a DMX controller.
Control Personalities
To set the control personality:

  1. Go to the DMX Channel main level.
  2. Select the desired personality, from 1 Ch, 4 Ch, 5 Ch, 7 Ch, 11 Ch, 13 Ch1, 13 Ch2, 17 Ch, or HSV.
    •See the Starting Address section for the highest selectable starting address for each personality.
    • Make sure that the starting addresses on the various products do not overlap due to the new personality setting.

Starting Address
Each product will respond to a unique starting address from the controller. All products with the same starting address will respond in unison. To set the starting address:

  1. Go to the DMX Address main level.
  2. Select the starting address (001–512).

The highest available starting address for each DMX mode is as follows:

Personality Address
1 Ch 512
4 Ch 509
5 Ch 508
7 Ch 506
11 Ch 502
Personality Address
13 Ch1 500
13 Ch2 500
17 Ch 496
HSV 510 

Virtual Color Wheel
The Ovation Rêve P-3 IP includes a feature called the Virtual Color Wheel (VCW). This feature is available as a standalone control mode for manual use and as a control channel in select DMX personalities. More than 30 premixed colors, custom blended by Chauvet engineers, are available to call up for easier programming.
The DMX values used to mix these colors are provided below. The overall intensity of the Ovation fixture can be adjusted to more closely replicate familiar industry-standard colors. A chart is available at www.chauvetprofessional.com to compare Chauvet’s premixed colors with popular gel colors. This chart is for comparison purposes only and is not an assertion that Chauvet’s premixed colors match any of the gel colors listed.
Virtual Color Wheel Chart

DMX Value Display Readout Red Green Blue Amber Mint
000 ó 005
006 ó 013 Md Yellow 255 225 000 255 037
014 ó 021 Lt Yellow 255 177 003 255 037
022 ó 028 Amb Yellow 255 220 000 255 000
029 ó 035 VLt Amber 195 000 015 255 057
036 ó 043 Lt Amber 255 000 011 255 061
044 ó 051 Md Amber 255 053 000 255 017
052 ó 059 Dk Amber 255 008 000 255 017
060 ó 067 Lt Red 255 000 003 014 000
068 ó 075 Md Red 255 000 002 000 000
076 ó 083 NC Pink 255 075 062 255 073
084 ó 091 Md Pink 255 075 057 255 041
092 ó 099 Dk Pink 218 077 057 255 061
100 ó 107 Md Red Amber 255 000 009 168 000
108 ó 115 Dk Red Amber 255 005 009 036 000
116 ó 121 Magenta 255 003 062 255 012
122 ó 130 Dk Magenta 255 000 055 000 000
131 ó 138 Lt Lavender 255 220 093 255 044
139 ó 146 Lt Blue 000 255 159 112 078
147 ó 154 VLt Blue 000 215 145 196 065
155 ó 162 Lt Blue2 000 215 132 52 092
163 ó 170 Blue 000 195 188 000 019
171 ó 178 Md Blue 000 163 190 000 068
179 ó 186 Dk Blue 000 128 193 000 038
187 ó 194 Indigo 053 009 255 000 000
195 ó 202 VDk Blue 007 084 116 000 000
203 ó 210 VDk Blue2 011 082 139 000 000
211 ó 218 Yel Green 000 255 002 025 000
219 ó 226 Green 000 255 009 000 175
227 ó 234 Turquoise 000 255 087 096 255
235 ó 242 Aqua 000 255 098 044 255
243 ó 250 Blue Green 000 255 026 008 000
251 ó 255

OVATIONREVEP3IP Multi Color Full Spectrum - icon The colors above are simulated renditions of the color output produced compared with other similar incandescent products. Chauvet makes no guarantee of the color output accuracy.
Color Temperature Chart

DMX Value Color Temperature Red Green Blue Amber Mint
000 ó 005 No function          
006 2800K 253 000 025 255 145
007 ó 012 2801–2899K          
013 2900K 253 003 028 255 153
014 ó 019 2901–2999K          
020 3000K 251 005 033 255 161
021 ó 026 3001–3099K          
027 3100K 248 007 036 255 169
028 ó 033 3101–3199K          
034 3200K 245 009 045 255 173
035 ó 040 3201–3299K          
041 3300K 242 013 047 255 182
042 ó 047 3301–3399K          
048 3400K 237 022 053 255 185
049 ó 054 3401–3499K          
055 3500K 230 030 058 255 185
056 ó 061 3501–3599K          
062 3600K 225 040 064 255 185
063 ó 068 3601–3699K          
069 3700K 221 048 070 255 185
070 ó 075 3701–3799K          
076 3800K 220 048 074 255 197
077 ó 082 3801–3899K          
083 3900K 220 050 079 255 203
084 ó 089 3901–3999K          
090 4000K 210 058 084 255 203
091 ó 096 4001–4099K          
097 4100K 205 063 088 255 203
098 ó 103 4101–4199K          
104 4200K 199 068 095 255 204
105 ó 110 4201–4299K          
111 4300K 189 069 098 255 204
112 ó 117 4301–4399K          
118 4400K 183 071 103 255 204
119 ó 124 4401–4499K          
125 4500K 174 078 107 255 204
126 ó 131 4501–4599K          
132 4600K 170 080 112 255 204
133 ó 138 4601–4699K          
139 4700K 166 089 119 255 204
140 ó 145 4701–4799K          
146 4800K 164 098 123 255 203
147 ó 152 4801–4899K          
153 4900K 163 100 129 255 205
154 ó 159 4901–4999K          
160 5000K 163 103 137 255 206
DMX Value Color Temperature Red Green Blue Amber Mint
161 ó 166 5001–5099K          
167 5100K 163 108 142 255 208
168 ó 173 5101–5199K          
174 5200K 163 116 147 255 208
175 ó 180 5201–5299K          
181 5300K 163 118 156 255 210
182 ó 187 5301–5399K          
188 5400K 162 122 162 255 216
189 ó 194 5401–5499K          
195 5500K 162 124 166 255 224
196 ó 201 5501–5599K          
202 5600K 162 127 172 255 229
203 ó 208 5601–5699K          
209 5700K 159 127 177 255 231
210 ó 215 5701–5999          
216 6000K 158 134 192 241 231
217 ó 222 6001–6499K          
223 6500K 152 152 206 225 231
224 ó 229 6501–6999K          
230 7000K 144 157 224 218 231
231 ó 236 7001–7499K          
237 7500K 127 172 238 218 231
238 ó 243 7501–7999K          
244 ó 255 8000K 122 175 255 200 231

OVATIONREVEP3IP Multi Color Full Spectrum - icon The color temperatures above are simulated renditions of the color output produced compared with a tungsten lamp at the specified color temperature. Chauvet makes no guarantee of the color output accuracy.
Control Channel Assignments and Values
7 Ch / 13 Ch2 / 13 Ch1 / 11 Ch / 7 Ch / 5 Ch / 4 Ch

4 5 7 11 13-1 13-2 17 Function Value Percent/Setting
1 1 1 1 1 1 Dimmer 000 ó 255 0–100%
2 2 2 Dimmer fine 000 ó 255 0–100%
1 2 3 2 3 3 Red 000 ó 255 0–100%
4 4 Red fine 000 ó 255 0–100%
2 3 4 3 5 5 Green 000 ó 255 0–100%
6 6 Green fine 000 ó 255 0–100%
3 4 5 4 7 7 Blue 000 ó 255 0–100%
8 8 Blue fine 000 ó 255 0–100%
4 5 6 5 9 9 Amber 000 ó 255 0–100%
10 10 Amber fine 000 ó 255 0–100%
5 6 7 6 11 11 Mint 000 ó 255 0–100%
12 12 Mint fine 000 ó 255 0–100%
7 8 7 13 13 Strobe 000 ó 010
011 ó 255
No function
Strobe, slow to fast
2 9 8 14 Virtual color wheel 000 ó 255 See Virtual Color Wheel Chart
4 5 7 11 13-1 13-2 17 Function Value Percent/Setting
3 10 9 15 Color temperature 000 ó 255 See Color Temperature Chart
4 11 10 16 Hue 000
001 ó 255
0
-25–25
         11      Auto programs 000  010
011 059
060  109
110  159
160  209
210  255
No function Auto program 1
Auto program 2
Auto program 3
Auto program 4
Auto program 5
12 Auto speed 000  255 Auto speed, slow to fast
         13    17  Control (hold for 3 seconds) 000  007
008  015
016  023
024  031
032  039
040  047
048  055
056  063
064  071
072  079
080  087
088  095
096  103
104  111
112  119
120  127
128  255
No function Dimmer reset Red shift on Red shift off S-curve dimmer Linear dimmer Square dimmer curve Inverse square dimmer curve Dimmer speed mode: OFF Dimmer speed 1 (fastest) Dimmer speed 2 Dimmer speed 3 (slowest) Fan auto Fan on Fan off Fan silent Reserved for future use

HSV

Channel Function Value Percent/Setting
1 Dimmer 000  255 0–100%
2 Saturation 000 255 0–100%
3 Value 000  255 0–100%

1 Ch

Channel Function Value Percent/Setting
1 Dimmer 000  255 0–100% (color set through display menu)

Standalone Configuration

Static Mode
The static mode options under VCW (Virtual Color Wheel) also include preset color temperatures and a manual color mixer.
Virtual Color Wheel
To select from the Virtual Color Wheel:

  1. Go to the VCW main level.
  2. Select the VCW option.
  3. Select the desired virtual gel color (see the Virtual Color Wheel Chart).
  4. Set the Dimmer value (0–255).

Color Temperature
To select a preset color temperature:

  1. Go to the VCW main level.
  2. Select the CCT option.
  3. Select the desired color temperature (see the Color Temperature Chart).
  4. Set the Dimmer value (0–255).
  5. If desired, set the Hue value (-25–25).

Manual Color Mixer
To manually mix a custom static color:

  1. Go to the VCW main level.
  2. Select the Manual option.
  3. Select the color to edit (Red, Green, Blue, Amber, or Mint).
  4. Set the value for the selected color (0–255).
  5. Repeat steps 3 and 4 until product outputs as desired.

Color X-Fade Speed
The Color X-Fade Speed option creates a fade transition between colors when using colors in the Virtual
Color Wheel or the Color Temperature chart.

  1. Go to the VCW main level.
  2. Select Color X-Fade Speed.
  3. Select Fade Speed 1–4 (from fast to slow) or Off (to turn off the fade transition between colors).

Auto Show
To select an automatic program:

  1. Go to the Auto Show main level.
  2. Select the desired auto program (Auto 1–5).
  3. Set the Speed value (1–100).

Configuration Settings
Red Shift
The Red Shift function imitates the dimming of a halogen lamp. To toggle Red Shift:

  1. Go to the Red Shift main level.
  2. Select On or Off.

Master/Slave
The Master/Slave mode allows a group of Ovation Rêve P-3 IP products (the slaves) to simultaneously duplicate the output of another Ovation Rêve P-3 IP (the master) without a DMX controller.
To set each of the slaves:

  1. Go to the Master/Slave main level
  2. Select Slave.

To set the master:

  1. Go to the Master/Slave main level
  2. Select Master.
  3. Select a standalone setting.
    • The master is the one that runs a program whether in Auto or Static mode.
    • Do not connect a DMX controller to the products configured for Master/Slave operation. The DMX controller may interfere with signals from the master.
    • The master should be the first product in the daisy chain.

Dimmer Curve
To set the dimmer curve:

  1. Go to the Dimmer Curve main level.
  2. Select the desired option (SCurve, Linear, Square, or Inverse Square).

Dimmer Profile
This setting determines how fast the output of the Ovation Rêve P-3 IP changes when the output value is modified. It provides four different options to simulate the dimming curve of an incandescent lighting product. To select a specific dimmer profile, do the following:

  1. Go to the Dimmer Mode main level.
  2. Select a dimmer curve (Off, Dimmer 1, Dimmer 2, or Dimmer 3).

Off: The output is proportional (linear) to the dimmer channel value.
OVATIONREVEP3IP Multi Color Full Spectrum - icon Dimmer 1–3: The output follows the dimmer value based on the corresponding dimmer curve, Dimmer 1 being the fastest.
Color Calibration
This setting determines the maximum output values for each color, which affects the appearance of the total color output.

  1. Go to the Color Calib main level.
  2. Select Off (LED values will be linear/uncalibrated), User Calib, or Factory Calib.
  3. For User Calib mode, select the color value to edit (Red, Green, Blue, Amber, or Mint).
  4. Set the maximum value for the selected color (125–255).
  5. Repeat steps 3 and 4 until the product outputs as desired.

Pulse Width Modulation
To set the Pulse Width Modulation (PWM) frequency of the LEDs on the Ovation Rêve P-3 IP:

  1. Go to the LED Frequency main level.
  2. Select the PWM Frequency (600Hz, 1200Hz, 2000Hz, 4000Hz, 6000Hz, or 25Khz).

Fan Mode
To set the fan speed mode:

  1. Go to the Fan Speed main level.
  2. Select Auto (fan speed will increase or decrease based on product temperature), Off (fan will stay off. Product output will decrease based on product temperature), Silent (fan will maintain a constant silent speed), or On (fan speed will always be at maximum).

When operating in Fan Mode: Off and Fan Mode: Silent, the fixture will become hotter to the touch than when using other fan modes. Use proper protective equipment to prevent burns. Keep a safe distance from flammable objects.
Paulmann Ceiling Lighting Accessories - Icon 1 When operating in Fan Mode: Off and Fan Mode: Silent, output of the fixture will be reduced and will not reach the same levels as when using other fan modes.
Display Backlight Timer
To set the amount of time the backlight on the Ovation Rêve P-3 IP’s display stays on after the last button is pressed on the control panel:

  1. Go to the Back Light main level.
  2. Select 10S (10 seconds), 30S (30 seconds), 2Min (2 minutes), or Always On (remains on).

Information
To view essential product information:

  1. Go to the Information main level.
  2. Select Fixture Hours, LED Hours, Version, or UID.

Factory Reset
To reset the product to factory settings:

  1. Go to the Factory Reset main level.
  2. Select No (to cancel) or Yes (to reset the product configuration).

. Maintenance

Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean each lighting product at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:

  1. Unplug the product from power.
  2. Wait until the product is at room temperature.
  3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
  4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
  5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
  6. Softly drag any dirt or grime to the outside of the transparent surface.
  7. Gently polish the transparent surfaces until they are free of haze and lint.

Paulmann Ceiling Lighting Accessories - Icon 1 Always dry the transparent surfaces carefully after cleaning them.
Torque Measurements
To maintain the IP rating when reassembling the product, use the given torque measurements for each of the following screws and bolts:

Fixture Parts Torque Rating (Kgf.cm) Torque Rating (lgb.in)
USB and DMX Connectors 6.5 5.64
Power Connectors 3.5 3.04
Covers 9.5 8.25

Vacuum Test Measurements
To ensure that the product has been reassembled correctly, use the IP Tester from Chauvet Professional to check the following data has the given measurements for the given method:

Parameters Values
Method Positive
Test pressure 4-5 kPa
Test duration 15 seconds
PASS state leak pressure <0.01 kPa

Technical Specifications

Dimensions and Weight

Length Width Height Weight
18.82 in (478 mm) 11.81 in (300 mm) 8.27 in (210 mm) 21.4 lb (9.8 kg)

Note: Dimensions in inches are rounded.
Power

Power Supply Type Range Voltage Selection
Switching (internal) 100 to 240 VAC, 50/60 Hz Auto-ranging
Parameter 100 V, 60 Hz 120 V, 60 Hz 208 V, 60 Hz 230 V, 50 Hz 240 V, 50 Hz
Consumption 275 W 274 W 267 W 265 W 265 W
Operating Current 2.78 A 2.31 A 1.38 A 1.25 A 1.22 A
Max. Output Current 13.6 A 13.6 A 13.6 A 13.6 A 13.6 A
Fuse T 6.3 A, 250 V T 6.3 A, 250 V T 6.3 A, 250 V T 6.3 A, 250 V T 6.3 A, 250 V
Power I/O U.S./Worldwide UK/Europe
Power Input Connector Seetronic Powerkon IP65 Seetronic Powerkon IP65
Power Output Connector Seetronic Powerkon IP65 Seetronic Powerkon IP65
Power Cable plug Edison Local plug
Light Source          
Type Color Quantity Power Current Lifespan
  Red 10      
  Green 10      
LED Blue 10 4.4 to 7.8 W 2.4 A 50,000 hours
  Amber 20      
  Mint 30      
Photometrics          
Lens Beam Angle Field Angle Illuminance @ 5 m
Narrow 11.9° 20.8° 6.910 lux
Medium 25.6° 37.8° 1,950 lux
Wide 29.3° 43.1° 1,475 lux
Very Wide 43.5° 87.9° 401 lux
Thermal          
Maximum External Temperature Cooling System
113 °F (45 °C) Fan-assisted Convection

Control

DMX I/O Connector Channel Range
3-pin XLR, 5-pin XLR 1, 4, 5, 7, 11, 13ch1, 13ch2, 17 or HSV

Ordering

Product Name Item Name Item Code UPC Number
OvationRêveP-3 IP OVATIONREVEP3IP 1031928 7.81462E+11

OVATIONREVEP3IP Multi Color Full Spectrum - icon 1Contact Us

General Information Technical Support
Chauvet World Headquarters
Address: 3360 Davie Rd., Suite 509
Davie, FL 33314
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084
Voice: 844-393-7575
Fax: 954-756-8015
Email: chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com
Chauvet U.K.
Address: Pod 1 EVO Park
Little Oak Drive, Sherwood Park
Nottinghamshire, NG15 0EB Website:
UK
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110
Email: UKtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu

Warranty & Returns
For warranty terms and conditions and return information, please visit our website.
For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg,
France, and Germany: www.chauvetlighting.eu/warranty-registration.
Ovation Rêve P-3 IP User Manual Rev. 4OVATIONREVEP - logo

Documents / Resources

OVATION OVATIONREVEP3IP Multi Color Full Spectrum [pdf] User Manual
OVATIONREVEP3IP Multi Color Full Spectrum, OVATIONREVEP3IP, Multi Color Full Spectrum, Color Full Spectrum, Full Spectrum, Spectrum

References

Leave a comment

Your email address will not be published. Required fields are marked *