Omada SG5428XF Campus Stackable Switch

Specifications
- Model: Omada Campus Stackable Switch SG5428XF
- Designed for: Enterprise and campus environments
- Features: Wirespeed performance, L2 and L3 management features, service features, high security
- Routing Protocols: Static Routing, RIP, OSPF
- Security Features: ACL, 802.1x, Dynamic ARP Inspection
- Management: SNMP, RMON, WEB, CLI
- Other Features: ERPS support, Link Aggregation (LACP), QoS, IGMP snooping/filtering
Package Contents
Check that all the components mentioned in the package contents section are available.
Safety Precautions
Follow the safety precautions to prevent any damage to the device during installation.
Installation Tools
Gather the necessary tools as listed in the manual for a smooth installation process.
Product Installation
Follow the step-by-step instructions provided in the manual for installing the Omada Campus Stackable Switch.
Business Networking Solution
Installation Guide
Omada Campus Stackable Switch
About this Installation Guide
This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during the installation. This Installation Guide is structured as follows: Chapter 1 Introduction This chapter describes the external components of the switch. Chapter 2 Installation This chapter illustrates how to install the switch. Chapter 3 Connection This chapter illustrates how to do the physical connection of the switch. Chapter 4 Configuration This chapter illustrates how to configure the switch. Appendix A Troubleshooting Appendix B Specifications

Audience
This Installation Guide is for:
Network Engineer
Network Administrator
Conventions
· Some models featured in this guide may be unavailable in your country or region. For local sales information, visit https://www.omadanetworks.com/.
· The figures in Chapter 2, Chapter 3, and Chapter 4 are for demonstration purposes only. Your switch may differ in appearance from that depicted.
· PoE budget calculations are based on laboratory testing. Actual PoE power budget is not guaranteed and will vary as a result of client limitations and environmental factors.
· This guide uses the specific formats to highlight special messages. The following table lists the notice icons that are used throughout this guide.

Remind to be careful. A caution indicates a potential which may result in device damage.
Remind to take notice. The note contains the helpful information for a better use of the product.
Designed for enterprise and campus, the Omada Campus Stackable Switch SG5428XF provides wirespeed performance and abundant L2 and L3 management features. It also provides a variety of service features and multiple powerful functions with high security.
The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, and OSPF come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for built-in redundancy and performance. ERPS supports rapid protection and recovery in a ring topology.

The switch is embedded with powerful software features: ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB and CLI Log-in bring abundant management policies.
The switch integrates multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance.
1.2 Appearance
Front Panel (The figure is for demonstration only. It may differ from your actual product.)
The front panel of SG5428XF is shown as the following figure.
LED
Console Port
Mode Selection
(USB/RJ45)
Button USB2.0 Port
SFP Slot
LED 1G RJ45 Port SFP+ Slot
LED Explanation
PWR1*
PWR2
Green On
Off
Green On
Yellow On**
Off
Green On
Off
Off
Indication
The switch is powered by PWR1. PWR2 is disconnected or it works improperly.
The switch is powered by PWR1. PWR1 and PWR2 are connected.*
The switch is powered by PWR2. PWR1 is disconnected or it works improperly.
The switch is powered off or both PWR1 and PWR2 work improperly.
*PWR1 is the primary power supply and it takes priority over PWR2.
**When both PWR1 and PWR2 work properly and the switch is powerd by PWR1, it takes 10-20 seconds for the LED PWR2 (yellow) to go out after PWR2 is unplugged.
Introduction 01
Omada Campus Stackable Switch
LED SYS
FAN
MST
Port 1-24
(When the Speed LED is on)
Port 1-24
(When the STK LED is on)
Port 2528
(When the Speed LED is on)
Indication Flashing: The switch works properly. On or Off: The switch works improperly. Green: All the fans work properly. Yellow: Not all the fans work properly. On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology. Green On: Running at 1000 Mbps, but no activity. Green Flashing: Running at 1000 Mbps and transmitting or receiving data. Yellow On: Running at 100 Mbps, but no activity. Yellow Flashing: Running at 100 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
On: The port number indicates the unit ID in the stack topology.
Green On: Running at 10 Gbps, but no activity. Green Flashing: Running at 10 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a USB Type-C console port, console input is active on only one console port at a time. By default, the USB Type-C connector takes precedence over the RJ45 connector.
USB Port Designed to install the USB flash disk for data storage. 100 Mbps/1000 Mbps RJ45 Port Designed to connect to the device with a bandwidth of 100 Mbps or 1000 Mbps.
SFP/SFP+ Slot SFP slot is designed to install the 1 Gbps SFP module. SFP+ slot is designed to install the 10 Gbps SFP+ module.
Note: The 4 RJ45 ports of SG5428XF form combo ports with 4 SFP slots, and they are not able to negotiate with a speed of 10 Mbps.
02 Introduction
Omada Campus Stackable Switch
Rear Panel The rear panel of SG5428XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot
Power Socket Grounding Terminal
Note: PWR1 is the primary power supply and it takes priority over PWR2.
Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Power Socket Connect the female connector of the power cord here, and the male connector to the AC power outlet. Make sure that the voltage of the power supply meets the requirement of the input voltage (100240V~ 50/60 Hz). Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/.
Caution: Please use the provided power cord.
Introduction 03
Omada Campus Stackable Switch
Chapter 2 Installation
2.1 Package Contents
Make sure that the package contains the following items. Please contact your distributor, if any of the listed items is damaged or missing. The figures are for demonstration only. The actual items may differ in appearance and quantity from the depicted.
One Switch
Power Cord and Console Cable
Installation Guide
Business Networking Solution
Installation Guide
Omada Campus Stackable Switch
Mounting Brackets, Screws and Rubber Feet
2.2 Safety Precautions
To avoid any device damage and bodily injury caused by improper use, you should observe the following rules.
Safety Precautions Keep the power off during the installation. Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is
well grounded. Use only the power cord provided with the switch. Make sure that the supply voltage matches the specifications indicated on the rear panel of the
switch. Ensure that the switch is installed in a well-ventilated environment and its ventilation hole is not
blocked. Do not open or remove the cover of the switch. Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never
use any other liquid cleaning method. Place the device with its bottom surface downward.
Site Requirements
Temperature/Humidity
04 Installation
Omada Campus Stackable Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity, but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board. To avoid the effect of static electricity on the operation of the switch, attach much importance to the following items: Dust the device regularly, and keep the indoor air clean. Keep the device well grounded and ensure that the static electricity has been transferred. Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, and impedance coupling. To decrease the interferences, make sure to take the following measures: Use the power supply that can effectively filter interference from the power grid. Keep the device far from high-frequency and strong-current devices such as radio transmitting
station. Use electromagnetic shielding when necessary. Lightning Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000 °C. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.
Installation 05
Omada Campus Stackable Switch Ensure that the rack and the device are well earthed. Make sure the power socket has a good contact with the ground. Keep a reasonable cabling system and avoid induced lightning. Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note: For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Installation Site
When installing the device on a rack or a flat workbench, attach much importance to the following items: The rack or workbench is flat, stable, and sturdy enough to support the weight of 5.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Installation Tools
Phillips screwdriver ESD-preventive wrist wrap Cables
Note: These tools are not included with our product. If needed, you can purchase them separately.
2.4 Product Installation
Desktop Installation To install the device on the desktop, follow the steps: 1. Set the device on a flat surface which is strong enough to support the entire weight of the device
with all fittings. 2. Remove the adhesive backing papers from the rubber feet. 3. Attach the rubber feet to the bottom of the device to prevent it from slipping when placed on a
desktop.
06 Installation
Figure 2-1
Desktop Installation
Omada Campus Stackable Switch
Feet Bottom of the Device Notch
Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below:
1. Check the efficiency of the grounding system and the stability of the rack.
2. Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as illustrated in the following figure.
Figure 2-2
Bracket Installation
Rack-mounting Bracket Screw
3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure.
Figure 2-3
Rack Installation
Rack
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Place the device with its bottom facing downwards. Mount devices in sequence from the bottom to top of the rack and ensure a certain clearance
between devices for the purpose of heat dissipation.
Installation 07
Omada Campus Stackable Switch
Chapter 3 Connection
3.1 Ethernet Port
Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows.
Figure 3-1
Connecting the RJ45 Port
RJ45 Port
RJ45 Cable
3.2 SFP/SFP+ Slot
The following figure demonstrates the connection of SFP/SFP+ slot to an SFP/SFP+ module.
Figure 3-2
Inserting the SFP/SFP+ Module
SFP/SFP+ Slot SFP/SFP+ Module
3.3 Console Port
CLI (Command Line Interface) enables you to manage the switch, thus you can load the CLI after connecting the PCs or Terminals to the console port on the switch via a cable (an RJ45 console cable is provided, while USB Type-C cable is not provided).
Connect the RJ45 console port of the device with your computer by the console cable as the following figure shows.
Figure 3-3
Connecting the RJ45 Console Port
08 Connection
Omada Campus Stackable Switch
Connect the USB Type-C console port of the device with your computer by the USB cable (not provided) as the following figure shows.
Figure 3-4
Connecting the USB Type-C Console Port
Note: Two console ports cannot be used concurrently. The USB Type-C console port takes priority
over the RJ45 console port. The USB Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the
device power off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Verify Installation
After completing the installation, verify the following items:
There should be 5 to 10 cm of clearance around the device for ventilation and make sure the air flow is adequate.
The voltage of the power supply meets the requirement of the input voltage of the device. The power socket, device and rack are well grounded. The device is correctly connected to other network devices.
3.5 Power On
Plug the female connector of the provided power cord into the power socket of the device and plug the positive connector into a power outlet as the following figure shows. Make sure that the voltage of the power supply meets the requirement of the input voltage (100-240 V~ 50/60 Hz).
Figure 3-5
Connecting to Power Supply
Note: The figure is to illustrate the application and principle. The provided plug and the socket in
your region may differ from the figures above.
Connection 09
Omada Campus Stackable Switch
3.6 Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly. During this time, its LED indicators will respond in the following order:
1. The PWR LED indicator lights on all the time. The SYS LED and the LED indicators of all the ports keep off.
2. After about one minute, the SYS LED and LED indicators of all the ports will flash momentarily and then turn off.
3. Several seconds later, the SYS LED indicator will flash, which represents a successful initialization.
3.7 Stack Topology
With stackable design, the switch can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-4 switches and enough 10G SFP+ modules/cables. For more details, see the table below:
Switch SG5428XF
Compatible Model(s) SG5428XF, SG5428X, SG5428XMPP, SG5452X, SG5452XMPP
Quantity 2-4
There are three stack topology structures for different scenarios, please build the proper topology according to your needs:
1. Chain Topology: Chain topology is relatively simple and does not require cable connection between the first and last unit. It is suitable for long-distance stacking, but its reliability is relatively low.
Figure 3-6
Chain Topology
Stacking Port Group 2
Stacking Port Group 1
2. Ring Topology: Ring topology has higher reliability compared with the chain topology. When one of the chains in the ring topology is disconnected, the ring topology becomes a chain topology, but the entire stack system can still work normally. The ring topology requires cable connection between the first and last unit, so it’s not suitable for long-distance stacking.
10 Connection
Figure 3-7
Ring Topology
Omada Campus Stackable Switch
Stacking Port Group 2
Stacking Port Group 1
3. Star Topology: Star topology connects the switches to a central main switch, therefore, it can significantly increase the data forwarding rate between member switches while providing unified management.
Figure 3-8
Star Topology
Note: · The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. · Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. · A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking
port. A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
Connection 11
Omada Campus Stackable Switch
Chapter 4 Configuration
4.1 Configuration Overview
The switch supports two configuration options:
Standalone Mode: Configure and manage the switch singly. Controller Mode: Configure and manage the network devices centrally. It is recommended in the
large-scale network, which consists of mass devices such as access points, switches, and gateways.
Note: When the switch is changed from Standalone Mode to Controller Mode, configurations of the switch will be lost. For details, refer to the related documents on the download center of our official website: https://support.omadanetworks.com/product/.
4.2 Standalone Mode
In Standalone Mode, use a computer to configure and manage the switch using GUI (Graphical User Interface) or CLI (command-line interface).
Figure 4-1
Topology for Standalone Mode
Switch
PC
Using the GUI
1. To access the management page of the switch, make sure the switch and computer are in the same subnet. Open a browser and type the switch’s IP address in the address field, then press the Enter key.
If the switch obtains IP address from the DHCP server (typically a gateway), find the switch’s IP address on the DHCP server.
If not, use the default IP address 192.168.0.1 to launch the switch’s management page.
2. The first time you log in, set the username and password to better protect your network and devices. After that, the system will automatically redirect you back to the login interface to authenticate with the newly created credentials.
3. After a successful login, the main page will appear. You can click the menus on the top side and left side to configure the corresponding functions.
For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://support.omadanetworks.com/product/.
12 Configuration
Omada Campus Stackable Switch
Using the CLI
Set up a Telnet or SSH connection to access the switch via CLI.
Use the console port to access the switch. When using the console port, start the terminal emulation program (such as the Hyper Terminal) on the PC and configure the terminal emulation program as follows:
Baud Rate 38400 bps
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://support.omadanetworks.com/product/.
Note: For certain devices, you may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Controller Mode
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Hardware Controller or Omada Software Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Hardware Controller
Omada Hardware Controller is a good alternative if you have no spare PC to keep running Omada Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Hardware Controller.
Figure 4-2
Manage the network via Omada Hardware Controller
Gateway Switch
Omada Hardware Controller AP
AP Clients
AP
Configuration 13
Omada Campus Stackable Switch
Note:
· Before you start, be sure to power up and connect your devices according to the topology figure. · A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the APs and clients in your local network. · Omada Controller must have network access to your Omada devices (the gateway, switch, or APs) in
order to find, adopt, and manage them.
1. Find the IP address of the gateway. Open the command line on your PC and enter ipconfig. In the result list, find the Default Gateway, which is also the IP address of the gateway.
2. Launch a web browser and enter the IP address of the gateway. Log into the gateway’s web page. Then go to Network > LAN > DHCP Client List to find the IP address of your controller according to its MAC address.
3. Enter the IP address of the your controller in the address bar to open its web page.
4. On the Omada Controller’s web page, follow the wizard to complete the quick setup.
5. After the quick setup, the login page appears. Enter the username and password you have created and click Log in. Then you can further configure the controller.
6. If you want to manage the devices reomotely, follow the next steps:
a. Make sure that Cloud Access is enabled on your controller. By default, Cloud Access is enabled. Make sure that the Cloud LED is flashing slowly.
b. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Enter your TP-Link ID and password to log in. Click + Add Controller and choose Hardware Controller to add your controller. Then you can further configure the controller.
For more details, refer to the Installation Guide of OC200/OC220/OC300/OC400.
Via Omada Software Controller
On a PC with Windows OS or Linux OS, download the Omada Software Controller from https:// support.omadanetworks.com/product/omada-software-controller/. Then run the file and follow the wizard to install the Omada Software Controller. Follow the steps below to configure the Controller.
Figure 4-3
Manage the network via Omada Software Controller
Gateway Switch
Controller
Omada Software Controller
running on the Host PC
AP
AP
AP
14 Configuration
Clients
Omada Campus Stackable Switch Note: To manage your devices, Omada Software Controller needs to keep running on your computer. 1. Launch the Omada Software Controller on your PC. After the initiation process, the controller
automatically opens its web page. If not, click Launch a Browser to Manage the Network. 2. On the Omada Controller’s web page, follow the wizard to complete the quick setup. 3. After the quick setup, the login page appears. Enter the username and password you have created
and click Log in. Then you can further configure the controller. 4. If you want to manage the devices reomotely, follow the next steps:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Controller’s web page, go to Settings > Cloud Access to enable Cloud Access and bind your TP-Link ID. If you have set it up in the quick setup, skip this step.
b. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Enter your TP-Link ID and password to log in. A list of controllers that have been bound with your TP-Link ID will appear. Then you can click Launch to further configure the controller.
* Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official website: https://support.omadanetworks.com/product/.
Configuration 15
Omada Campus Stackable Switch
Appendix A Troubleshooting
Q1. What could I do if I forgot the username and password of the switch?
1. Connect the console port of the PC to the console port of the switch and open a terminal emulation program.
2. Power off and restart the switch. Perform the action indicated by the terminal emulation program to reach the bootUtil menu. The action differs from product to product. Possible actions are listed below: · Press any key to stop autoboot. · Press CTRL-B to reach the bootUtil menu.
3. The bootUtil menu will be shown. Enter the number 6 to select the “Password recovery” option and enter Y to delete all the users and passwords. Then you can reset the username and password.
Q2. Why does the PWR LED work abnormally? The PWR/Power LED should be lit up when the power system works normally. If the PWR/Power LED worked abnormally, take the following steps:
1. Make sure that the power cable is connected properly, and the power contact is normal. 2. Make sure the voltage of the power supply meets the requirement of the input voltage of the
switch.
Q3. What should I do if I cannot access the web management page? Try the following:
1. Check every port LED on the switch and make sure the Ethernet cable is connected properly. 2. Try another port on the switch and make sure the Ethernet cable is suitable and works normally. 3. Power off the switch and, after a while, power it on again. 4. Make sure the IP address of your PC is set within the subnet of the switch. 5. If you still cannot access the configuration page, reset the switch to its factory defaults. Then
the IP address of your PC should be set as 192.168.0.x (“x” is any number from 2 to 254) and subnet mask as 255.255.255.0.
Q4. Why is the terminal emulation program not displaying correctly? Try the following:
1. Make sure the power supply is normal and the console cable is properly connected. 2. Check if the console cable is the right type. 3. Ensure the parameters of the terminal emulation program are correct: configure Bits per second
as 38400, Data bits as 8, Parity as None, Stop bits as 1, and Flow control as None.
16 Appendix A Troubleshooting
Omada Campus Stackable Switch
Appendix B Specifications
Item Standards
Content IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Transmission Medium
100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m)
1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
100BASE-FX/LX10/BX10: MMF, SMF 1000BASE-SX/LX/LX10/BX10: MMF, SMF
10GBASE-SR/LR: MMF, SMF 10GSFP+CU SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M)
LED
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
PWR1, PWR2, SYS, FAN, MST, Speed, STK, Port 1-24, Port 25-28 -5 °C to 45 °C (23 °F to 113 °F) -40 °C to 70 °C (-40 °F to 158 °F) 10% to 90% RH Non-condensing 5% to 90% RH Non-condensing
Appendix B Specifications 17
CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
EU Declaration of Conformity
TP-Link hereby declares that the switch is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863. The original EU Declaration of Conformity may be found at https://www.tp-link.com/en/support/ce/
UK Declaration of Conformity
TP-Link hereby declares that the switch is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016. The original UK Declaration of Conformity may be found at https://www.tp-link.com/support/ukca/
, .
Safety Information
· Keep the device away from water, fire, humidity or hot environments. · Do not attempt to disassemble, repair, or modify the device.If you need service, please contact us. · Place the device with its bottom surface downward. · The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be
easily accessible. · Plug the product into the wall outlets with earthing connection through the power supply cord
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The operating temperature for the device shall be within -5°C~45°C (23°F~113°F). · : -5°C~45°C (23°F~113°F)
This equipment is not suitable for use in locations where children are likely to be present.
18
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.
19
For technical support, user guides and other information, please visit https://support.omadanetworks.com/, or simply scan the QR code.
© 2025 TP-Link 7100000950 REV1.0.0
Documents / Resources
![]() | SG5428XF Campus Stackable Switch |
References
- omada.tplinkcloud.comomada.tplinkcloud.com
- Omada Software Controller | A Free On-Premises Software Controller for Centralized Management | Omada Network Supportsupport.omadanetworks.com
- Omada Network Supportsupport.omadanetworks.com
- Product Support | Omada Network Supportsupport.omadanetworks.com
- lightning_protection_guidesupport.omadanetworks.com
- Omada - Networks Empower Business | TP-Linkwww.omadanetworks.com
- CE Regulatory Compliance | TP-Linkwww.tp-link.com
- Regulatory Compliance | TP-Linkwww.tp-link.com
- User Manualmanual.tools