Malfunction remedy 

Malfunction Possible cause Remedy
Unit is not operating No mains voltage Check the mains voltage.
Water housing is open (safety Turn the head of the unit clock-
Delivery or fountain height Nozzle blocked Unscrew and clean the nozzle
insufficient or not con insert
consistent, The loss of pressure on the pipe to the watercourse/water feature is too high Reduce hose length and connect parts to a minimum, route hoses as
straight as possible
Cloudy water Intake openings blocked Clean housing
Filter media clogged Clean filter media
Impeller unit blocked Clean the running unit
Pond extremely dirty Remove algae and leaves from
the pond, change the water
Quartz glass tube soiled Clean the quartz glass tube
Flow regulator excessively throttled Set flow regulator
The UVC lamp is not lit The UVC lamp overheats. After cooling down, the UVC
The temperature monitor turned off the UVC lamp lamp switches on again auto matically
The UVC lamp is defective Replace the UVC lamp.
The UVC lamp is not inserted into the socket properly Insert the UVC lamp correctly
into the socket
The unit switches off after a
short running period
Water temperature too high Observe the maximum water
temperature of +77 °F (+35 °C)

Documents / Resources

Oase 400 Filtral UVC All in one Pump and Filter Unit [pdf] Instruction Manual
400, 800, 1600, Filtral UVC All in one Pump and Filter Unit
Oase 400 Filtral UVC All In One Pump and Filter Unit [pdf] Instruction Manual
400, 800, 1600, Filtral UVC All In One Pump and Filter Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *