  • Unit Type: Metered
  • Orientation: Outlet
  • Qty & Type: Monitored Input Vertical, 0U Mid (30)C13/C15, (6)C13/C15/C19 200-240VAC
  • Input Voltage: 200-240VAC
  • Input Current: 30A (24A derated)
  • Breaker Qty & Type: (3) 20AMP, double-pole, 5KA
  • Input Phase: Three-phase, Wye(L21-30P)/Delta(L15-30P)
  • Rated Power: 8.6 KVA

Product Usage Instructions

Installation

  1. Ensure installation complies with all applicable national, state, and local codes.
  2. Refer to the identification table for input cord length and other specifications.
  3. Follow the detailed installation instructions in the quickstart guide.
  4.  Connect external earth ground to the provided threaded nut.

Metering Attributes
The unit provides metering accuracy for voltage(V), current(A), apparent power(kVA), real power(kW), power factor, and energy(kWh).

Metered Components
The metered components include input(phase) and circuit breakers.

Environmental Conditions

  • Operating Temperature: -5 to 60°C (23 to 140°F)
  • Storage Temperature: -20 to 60°C (-4 to 140°F)
  • Humidity (Operating/Storage): 5-90% RH / 5-95% RH; non-condensing
  • Max Operating Elevation, Above MSL: 3000m (9840ft)

Frequently Asked Questions (FAQ)
Q: What is the input voltage range for this product?
A: The input voltage range is 200-240VAC.
Q: What is the maximum operating elevation above mean sea level?
A: The maximum operating elevation is 3000 meters (9840 feet).

Instruction

nVent-EN1853-Tooless-Mounting-Button-Locations- (2)

TECHNICAL SPECIFICATIONS

nVent-EN1853-Tooless-Mounting-Button-Locations- (3)

nVent-EN1853-Tooless-Mounting-Button-Locations- (4)

NOTES:

  1. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES.
  2. PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS ARE IN [INCHES]
  3. THE UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
    BRACKET IS PROVIDED WITH THE UNIT.
  4. DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK START GUIDE
  5. CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT
  6. SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
  7. iNPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUALRATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ PLUGS ARE EMEA RATED ONLY

THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICEnVent-EN1853-Tooless-Mounting-Button-Locations- (5)

nVent-EN1853-Tooless-Mounting-Button-Locations- (6)

RECEPTACLE nVent-EN1853-Tooless-Mounting-Button-Locations- (7)

nVent-EN1853-Tooless-Mounting-Button-Locations- (8)

NOTES :

  1. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES.
  2. SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION nVent-EN1853-Tooless-Mounting-Button-Locations- (9)nVent-EN1853-Tooless-Mounting-Button-Locations- (10)

nVent-EN1853-Tooless-Mounting-Button-Locations- (11)

NOTES:

  1. INTERNAL WIRING
    • WIRE TYPE: UL AWM 1015,10 & 12 & 18 AWG
    • LINE 1/R/X COLOR: BLACK
    • LINE 2/S/Y COLOR: ORANGE
    • LINE 3/T/Z COLOR: RED
    • EARTH GROUND COLOR: GREEN/YELLOW
  2. FOR FINISHED GOOD PART NUMBER SEE IDENTIFICATION

COMPLIANCE LABEL

nVent-EN1853-Tooless-Mounting-Button-Locations- (12)

INTERNAL WIRING SCHEMATIC DIAGRAM

nVent-EN1853-Tooless-Mounting-Button-Locations- (1)

NOTES:

  1. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES.
  2. SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION.
  3. THIS DRAWING DEPICTS THE POWER SYSTEM CONNECTIONS AND IS NOT REPRESENTATIVE OF THE PHYSICAL LAYOUT. PLEASE REFER TO MECHANICAL DRAWINGS FOR PHYSICAL LAYOUT.

Documents / Resources

nVent EN1853 Tooless Mounting Button Locations [pdf] Instruction Manual
EN1853, P59411, TA-EN1853-WXYZHP, EN1853 Tooless Mounting Button Locations, EN1853, Tooless Mounting Button Locations, Mounting Button Locations, Button Locations, Locations

References

Leave a comment

Your email address will not be published. Required fields are marked *