NuTone FG7TE Series Fixed Speed High-Efficiency Gas Furnace

NuTone-FG7TE-Series-Fixed-Speed-High-Efficiency-Gas-Furnace-PRO

Technical Specifications

FG7TE Series
Two Stage, Fixed Speed ECM, High-Efficiency Upflow Gas Furnaces Induced Draft – 96% AFUE Input 60,000 – 115,000 Btuh

Features and Benefits
The high-efficiency upflow gas furnace may be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing appliance appearance. Design certified by CSA for application in Canada and the United States.

Location of Furnace Components

  • Flame Sensor
  • Finish Flange
  • Roll-Out Switch
  • Pressure Switches (Inducer)
  • Main Air Limit Switch
  • Inducer Limit Switch
  • Inducer Assembly
  • Blower Door Switch
  • Burner Assembly
  • Igniter
  • Gas Valve Furnace Control Board
  • Pressure Switches (Condensate)
  • Transformer
  • Motor Control Box
  • Motor Choke (C & D cabinets only)
  • Motor Control Board
  • Blower Assembly

Air Flow
Upflow Gas Furnace Components:

  • Cabinet Size A: Dim. B = 17 1/2, Dim. C = 16 1/8
  • Cabinet Size B: Dim. B = 21, Dim. C = 19 5/8
  • Cabinet Size C: Dim. B = 24 1/2, Dim. C = 23 1/8

Dimensions
TE 96% Upflow Furnace Cabinet:

  • Size A: Dim. A = 17 1/2, Dim. B = 15 7/8
  • Size B: Dim. A = 21, Dim. B = 19 3/8
  • Size C: Dim. A = 24 1/2, Dim. B = 22 7/8

Model Identification Code
FG7TE Model Numbers:

  • Model: FG7TE
  • Design Series: E (96% Upflow)
  • Input Heating Capacity: D (115,000 Btuh)
  • Cabinet Width: E (24.50)
  • Cooling Airflow: C1 (3-5 Tons)
  • Motor Technology: T (5 Tap ECM)

Specifications

Model Number Input – Btuh (a) Heating Capacity – BtuH AFUE Motor H.P. Speed – Type Motor FLA Rated Ext. SP – In. W.C. Temperature Rise Range – F Shipping Weights SKU
FG7TE-060D-E24B1 60,000 / 39,000 58,000 / 37,000 96.0 3/4 – BLDC 8.8 0.50 30-60 120 lb 1025958F
FG7TE-080D-E35C1 80,000 / 52,000 77,000 / 50,000 96.0 1 – BLDC 11.5 0.50 30-60 130 lb 1025959F
FG7TE-100D-E35C1 100,000 / 65,000 96,000 / 62,000 96.0 1 – BLDC 11.5 0.50 35-65 135 lb 1025960F
FG7TE-115D-E45D1 115,000 / 74,750 110,000 / 72,000 96.0 1 – BLDC 11.5 0.50 40-70 145 lb 1025961F

Frequently Asked Questions

  • Q: Where can the high-efficiency upflow gas furnace be installed?
    A: The furnace can be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet.
  • Q: What is the AFUE rating of the furnace?
    A: The furnace has an AFUE rating of 96%.
  • Q: What is the voltage and frequency of the gas furnace?
    A: All models are 115V, 60 Hz.
  • Q: What type of gas connections does the furnace have?
    A: The gas connections are 1/2 N.P.T.
  • Q: How does the motor technology work?
    A: The motor technology used is 5 Tap ECM, which provides efficient and variable speed control.

The high-efficiency upflow gas furnace may be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in Canada and the United States.

FEATURES and BENEFITS

  • Multi-speed Direct Drive Blower: Energy-efficient brushless DC (ECM) fixed-speed motor offers 16 speeds designed to give a wide range of cooling capacities.
  • SmartLite® Technology: Auto-adjusts igniter on time to extend igniter life.
  • Hot Surface Igniter: Innovative application of a silicon nitride type igniter.
  • 30 Second Blower Delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
  • 30-Second Post Purge: Increases life of heat exchanger.
  • 60-Second Fixed Cooling Cycle Blower-Off Delay (TDR): Increases cooling performance when matched with a Nortek Global HVAC coil.
  • Color Coded Wire Harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • Diagnostic Lights: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
  • Integrated Control Boards: With connections for electronic air cleaner, humidifier, and dehumidifiers. Ergonomically located for ease of service.
  • 2 Stage Inducer: Optimizes efficiency on first-stage heat and reduces sound levels.
  • Heat Exchanger: Heavy gauge aluminized steel primary heat exchanger and stainless steel secondary heat exchanger assures a long life.
  • 100% Fired and Tested: All units and each component are tested on the manufacturing line.
  • Best Packaging in the Industry: Unique corner post design assures product will arrive to the homeowner dent-free.
  • Flexible Category IV Venting System: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum installation flexibility.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • LP Convertible: Simple burner orifice and regulator spring change for ease of convertibility (as an accessory).
  • Two-Piece Door Design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
  • Blower Compartment: Sealed door to reduce air leakage and insulated for ultra-quiet operation.
  • Sealed Vestibule: Reduces burner and inducer sound levels.
  • Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it’s needed.

LOCATION OF FURNACE COMPONENTS

NuTone-FG7TE-Series-Fixed-Speed-High-Efficiency-Gas-Furnace- (1)

DIMENSIONS

NuTone-FG7TE-Series-Fixed-Speed-High-Efficiency-Gas-Furnace- (2)NuTone-FG7TE-Series-Fixed-Speed-High-Efficiency-Gas-Furnace- (3)

SPECIFICATIONS

FG7TE MODEL NUMBERS -060D-E24B1 -080D-E35C1 -100D-E35C1 -115D-E45D1
Input – Btuh (a) 60000 / 39000 80000 / 52000 100000 / 65000 115000 / 74750
Heating Capacity – BtuH 58000 / 37000 77000 / 50000 96000 / 62000 110000 / 72000
AFUE 96.0 96.0 96.0 96.0
Motor H.P. – Speed – Type 3/4 – BLDC 1 – BLDC 1 – BLDC 1 – BLDC
Motor FLA 8.8 11.5 11.5 11.5
Rated Ext. SP – In. W.C. 0.50 0.50 0.50 0.50
Temperature Rise Range – F 30-60 30-60 35-65 40-70
Shipping Weights 120 lb 130 lb 135 lb 145 lb
SKU 1025958F 1025959F 1025960F 1025961F

Note: All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

G7TE-060D-E24B1 (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5
1 2 3 4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
G7TE-060D-E24B1 60,000 BTU/hr 0 0 0 0                    
1 0 0 0                    
0 1 0 0                    
1 1 0 0                    
0 0 1 0                    
1 0 1 0 940 57 890 60            
0 1 1 0 990 54 945 56 905 59        
1 1 1 0 1,055 51 1,015 53 970 55 930 57 890 60
0 0 0 1 1,135 47 1,095 49 1,055 51 1,010 53 960 56
1 0 0 1 1,185 45 1,145 47 1,105 48 1,065 50 1,030 52
0 1 0 1 1,250 43 1,210 44 1,170 46 1,135 47 1,095 49
1 1 0 1 1,290 41 1,255 42 1,220 44 1,180 45 1,145 47
0 0 1 1 1,315 41 1,275 42 1,240 43 1,200 44 1,160 46
1 0 1 1 1,350 40 1,315 41 1,280 42 1,245 43 1,205 44
0 1 1 1 1,390 38 1,350 40 1,315 41 1,275 42 1,240 43
1 1 1 1                    
COOLING AIRFLOW (CFM)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
5 6 7 8 CFM CFM CFM CFM CFM CFM CFM CFM
G7TE-060D-E24B1 60,000 BTU/hr 0 0 0 0                
1 0 0 0                
0 1 0 0                
1 1 0 0 725              
0 0 1 0 810              
1 0 1 0 940 890 845 795 750 700    
0 1 1 0 990 945 905 860 820 775 735 690
1 1 1 0 1,055 1,015 970 930 890 845 805 760
0 0 0 1 1,135 1,095 1,055 1,010 960 930 890 850
1 0 0 1 1,185 1,145 1,105 1,065 1,030 990 950 910
0 1 0 1 1,250 1,210 1,170 1,135 1,095 1,055 1,020 980
1 1 0 1 1,290 1,255 1,220 1,180 1,145 1,110 1,075 1,040
0 0 1 1 1,315 1,275 1,240 1,200 1,160 1,120 1,085 1,045
1 0 1 1 1,350 1,315 1,280 1,245 1,205 1,170 1,135 1,100
0 1 1 1 1,390 1,350 1,315 1,275 1,240 1,200 1,160 1,125
1 1 1 1 1,420 1,380 1,345 1,310 1,270 1,235 1,200 1,160

*NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government-mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government-mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low-stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

FG7TE-080D-E35C1 (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5
1 2 3 4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
FG7TE-080D-E35C1 80,000 BTU/hr 0 0 0 0 1,125 63                
1 0 0 0 1,205 59 1,120 63            
0 1 0 0 1,305 54 1,225 58 1,150 62        
1 1 0 0 1,430 50 1,350 53 1,270 56 1,190 60 1,110 63
0 0 1 0 1,525 47 1,450 49 1,375 52 1,300 55 1,225 57
1 0 1 0 1,620 44 1,540 46 1,465 49 1,390 51 1,315 54
0 1 1 0 1,695 42 1,620 44 1,545 46 1,465 49 1,390 51
1 1 1 0 1,770 40 1,700 42 1,630 44 1,555 46 1,485 47
0 0 0 1 1,875 38 1,805 39 1,730 41 1,655 43 1,580 45
1 0 0 1 1,905 37 1,840 39 1,775 40 1,710 42 1,640 43
0 1 0 1 1,980 36 1,910 37 1,845 39 1,780 40 1,715 41
1 1 0 1 2,025 35 1,960 36 1,895 38 1,830 39 1,765 40
0 0 1 1     2,025 35 1,960 36 1,900 37 1,840 38
1 0 1 1         2,010 35 1,945 37 1,880 37
0 1 1 1             2,035 35 1,980 36
1 1 1 1                    
COOLING AIRFLOW (CFM)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
5 6 7 8 CFM CFM CFM CFM CFM CFM CFM CFM
FG7TE-080D-E35C1 80,000 BTU/hr 0 0 0 0 1,125 1,040 960 880 795      
1 0 0 0 1,205 1,120 1,040 960 875 795    
0 1 0 0 1,305 1,225 1,150 1,070 995 915 840  
1 1 0 0 1,430 1,350 1,270 1,190 1,110 1,030 950 865
0 0 1 0 1,525 1,450 1,375 1,300 1,225 1,150 1,075 1,000
1 0 1 0 1,620 1,540 1,465 1,390 1,315 1,240 1,165 1,090
0 1 1 0 1,695 1,620 1,545 1,465 1,390 1,315 1,235 1,160
1 1 1 0 1,770 1,700 1,630 1,555 1,485 1,410 1,340 1,265
0 0 0 1 1,875 1,805 1,730 1,655 1,580 1,510 1,435 1,340
1 0 0 1 1,905 1,840 1,775 1,710 1,640 1,575 1,510 1,445
0 1 0 1 1,980 1,910 1,845 1,780 1,715 1,650 1,580 1,515
1 1 0 1 2,025 1,960 1,895 1,830 1,765 1,700 1,635 1,570
0 0 1 1 2,085 2,025 1,960 1,900 1,840 1,775 1,715 1,655
1 0 1 1 2,135 2,070 2,010 1,945 1,880 1,815 1,750 1,685
0 1 1 1 2,200 2,145 2,090 2,035 1,980 1,925 1,870 1,820
1 1 1 1 2,280 2,225 2,170 2,115 2,065 2,010 1,955 1,900

NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government-mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. comply with government-mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low-stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

FG7TE-100D-E35C1 (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5
1 2 3 4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
FG7TE-100D-E35C1 100,000 BTU/hr 0 0 0 0                    
1 0 0 0                    
0 1 0 0                    
1 1 0 0                    
0 0 1 0                    
1 0 1 0 1,620 55 1,540 58            
0 1 1 0 1,695 52 1,620 55 1,545 58        
1 1 1 0 1,770 50 1,700 52 1,630 55 1,555 57 1,485 60
0 0 0 1 1,875 47 1,805 49 1,730 51 1,655 54 1,580 56
1 0 0 1 1,905 47 1,840 48 1,775 50 1,710 52 1,640 54
0 1 0 1 1,980 45 1,910 47 1,845 48 1,780 50 1,715 52
1 1 0 1 2,025 44 1,960 45 1,895 47 1,830 49 1,765 50
0 0 1 1 2,085 43 2,025 44 1,960 45 1,900 47 1,840 48
1 0 1 1 2,135 42 2,070 43 2,010 44 1,945 46 1,880 47
0 1 1 1                    
1 1 1 1                    
COOLING AIRFLOW (CFM)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
5 6 7 8 CFM CFM CFM CFM CFM CFM CFM CFM
FG7TE-100D-E35C1 100,000 BTU/hr 0 0 0 0 1,125 1,040            
1 0 0 0 1,205 1,120 1,040          
0 1 0 0 1,305 1,225 1,150 1,070 995      
1 1 0 0 1,430 1,350 1,270 1,190 1,110 1,030    
0 0 1 0 1,525 1,450 1,375 1,300 1,225 1,150 1,075 1,000
1 0 1 0 1,620 1,540 1,465 1,390 1,315 1,240 1,165 1,090
0 1 1 0 1,695 1,620 1,545 1,465 1,390 1,315 1,235 1,160
1 1 1 0 1,770 1,700 1,630 1,555 1,485 1,410 1,340 1,265
0 0 0 1 1,875 1,805 1,730 1,655 1,580 1,510 1,435 1,340
1 0 0 1 1,905 1,840 1,775 1,710 1,640 1,575 1,510 1,445
0 1 0 1 1,980 1,910 1,845 1,780 1,715 1,650 1,580 1,515
1 1 0 1 2,025 1,960 1,895 1,830 1,765 1,700 1,635 1,570
0 0 1 1 2,085 2,025 1,960 1,900 1,840 1,775 1,715 1,655
1 0 1 1 2,135 2,070 2,010 1,945 1,880 1,815 1,750 1,685
0 1 1 1 2,200 2,145 2,090 2,035 1,980 1,925 1,870 1,820
1 1 1 1 2,280 2,225 2,170 2,115 2,065 2,010 1,955 1,900

*NOTES:

  1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government-mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government-mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low-stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

FG7TE-115D-E45D1 (FSHE)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5
1 2 3 4 CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
FG7TE-115D-E45D1 115,000 BTU/hr 0 0 0 0                    
1 0 0 0                    
0 1 0 0                    
1 1 0 0                    
0 0 1 0                    
1 0 1 0 1,760 58 1,715 60            
0 1 1 0 1,835 56 1,790 57 1,745 59        
1 1 1 0 1,885 54 1,840 56 1,790 57 1,745 59 1,700 60
0 0 0 1 1,945 53 1,900 54 1,850 55 1,805 57 1,760 58
1 0 0 1 1,950 52 1,905 54 1,860 55 1,820 56 1,775 58
0 1 0 1 2,075 49 2,030 50 1,990 51 1,945 53 1,900 54
1 1 0 1 2,125 48 2,085 49 2,040 50 2,000 51 1,955 52
0 0 1 1 2,170 47 2,130 48 2,090 49 2,045 50 2,005 51
1 0 1 1 2,215 46 2,180 47 2,140 48 2,105 49 2,070 49
0 1 1 1                    
1 1 1 1                    
COOLING AIRFLOW (CFM)
Model Number/ Heating Input MOTOR SWITCH SETTINGS (0=OFF, 1=ON) External Static Pressure (in.w.c.)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
5 6 7 8 CFM CFM CFM CFM CFM CFM CFM CFM
FG7TE-115D-E45D1 115,000 BTU/hr 0 0 0 0 1,395 1,350 1,305 1,260 1,210 1,165 1,120  
1 0 0 0 1,465 1,420 1,375 1,330 1,290 1,245 1,200 1,155
0 1 0 0 1,555 1,510 1,470 1,425 1,380 1,340 1,295 1,250
1 1 0 0 1,625 1,585 1,540 1,500 1,460 1,415 1,375 1,335
0 0 1 0 1,690 1,650 1,610 1,570 1,530 1,485 1,445 1,405
1 0 1 0 1,760 1,715 1,670 1,625 1,575 1,530 1,485 1,440
0 1 1 0 1,835 1,790 1,745 1,695 1,650 1,605 1,555 1,510
1 1 1 0 1,885 1,840 1,790 1,745 1,700 1,655 1,610 1,565
0 0 0 1 1,945 1,900 1,850 1,805 1,760 1,710 1,665 1,620
1 0 0 1 1,950 1,905 1,860 1,820 1,775 1,735 1,690 1,650
0 1 0 1 2,075 2,030 1,990 1,945 1,900 1,855 1,810 1,770
1 1 0 1 2,125 2,085 2,040 2,000 1,955 1,910 1,870 1,825
0 0 1 1 2,170 2,130 2,090 2,045 2,005 1,965 1,925 1,880
1 0 1 1 2,215 2,180 2,140 2,105 2,070 2,035 2,000 1,965
0 1 1 1         2,225 2,165 2,100 2,040
1 1 1 1           2,170 2,120 2,065

NOTES:

  1. For motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8.
  2. To comply with government-mandated efficiency standards, two openings are required for airflows above 1,600 CFM.
  3. Data is shown without filter.
  4. Temperature rises in the table are approximate. Actual temperature rises may vary.
  5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range.
  6. To comply with government-mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode.
  7. When in low-stage heat, the airflow is approximately 70% of the table’s high value (2-stage furnaces only).

VENTING

All models are approved for vertical non-direct (1 pipe) and direct (2 pipe) venting applications. See the Vent Table below for specified sizes and allowable lengths.

FURNACE MODELS (BTU) FURNACE INSTALLATION SINGLE PIPE LENGTH (FT.) with 1 long radius elbow** DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH 1 long radius elbow on each pipe**
OUTLET OUTLET INLET/OUTLET INLET/OUTLET
2” Diameter 3” Diameter 2” Diameter 3” Diameter
60,000 Upflow 90 90 60 90
80,000 Upflow 40 90 40 90
100,000 Upflow 30 90 30 90
115,000 Upflow N/A 90 N/A 90

NOTES:

  1. Subtract 2.5 ft. for each additional 2-inch long radius elbow, 5 ft. for each additional 2-inch short radius elbow, 3.5 ft. for each additional 3-inch long radius elbow, and 7 ft. for each additional 3-inch short radius elbow. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
  2. Two 45-degree elbows are equivalent to one 90-degree elbow.
  3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.

ACCESSORIES

FG7TE KITS
Description SKU
2″ Concentric Vent Kit 904177
3″ Concentric Vent Kit 904176
2″ Concentric Vent Kit (Canadian Approved) 904952
3″ Concentric Vent Kit (Canadian Approved) 904953
2″ Side Wall Vent Kit 904617
3″ Side Wall Vent Kit 904347
U.S. LP Conversion Kit (0 to 10,000 ft.) 905028
Canada LP Conversion Kit (0 to 4,500 ft.) 905029
Bottom Return Filter 20 per Box, “B” Cabinet 904916
Bottom Return Filter 20 per Box, “D” Cabinet 904918
Side Return Filter Kit 541036
Neutralizer Kit 902377

NuTone-FG7TE-Series-Fixed-Speed-High-Efficiency-Gas-Furnace- (4)

GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this product that fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (06/2019)

www.nutonehvac.com

NuTone® trademark used under license. © Nortek Global HVAC, LLC. All Rights Reserved.

Documents / Resources

NuTone FG7TE Series Fixed Speed High Efficiency Gas Furnace [pdf] Owner's Manual
FG7TE-060D-E24B1, FG7TE-080D-E35C1, FG7TE Series Fixed Speed High Efficiency Gas Furnace, FG7TE, Series Fixed Speed High Efficiency Gas Furnace, Fixed Speed High Efficiency Gas Furnace, Speed High Efficiency Gas Furnace, High Efficiency Gas Furnace, Efficiency Gas Furnace, Gas Furnace, Furnace

References

Leave a comment

Your email address will not be published. Required fields are marked *