novus V1.0x C Telik Gardo Reader
Product Information
Specifications
- Product Name: TELIK GARDO READER
- User Guide Version: V1.0x C
- Manufacturer: NOVUS AUTOMATION
Product Usage Instructions
Safety Alerts
Refer to the safety alerts section in the user manual for important safety information.
Introduction
Provide an overview of the product and its capabilities.
Installation
Electrical Installation
Follow the recommendations for electrical installation provided in the user manual. Connect the power supply as instructed.
Mechanical Installation
Install the device mechanically as per the guidelines outlined in the manual.
Communication Interfaces
The device supports USB and RS485 communication interfaces. Follow the instructions for connecting these interfaces.
How to Install the Configuration Software
Install the USB driver, configurator software, and connect the device to a computer following the steps provided in the manual.
How to Use the TELIK GARDO Software
Learn how to run the software for the first time and navigate its interface effectively.
Modbus-RTU Protocol
Understand and implement the Modbus-RTU protocol for communication purposes.
FAQ
- Q: What should I do if the device does not power on?
A: Check the power connections and ensure they are secure. Refer to the troubleshooting section in the user manual for further assistance. - Q: Can I use third-party software with the TELIK GARDO READER?
A: While the device is designed to work with its proprietary software, compatibility with third-party software may vary. Refer to the manufacturer’s guidelines for more information.
SAFETY ALERTS
The following symbols are used on the equipment and throughout this manual to draw the user’s attention to valuable information related to the safety and use of the equipment.
All safety recommendations appearing in this manual must be followed to ensure personal safety and prevent damage to the instrument or system. If the instrument is used in a manner other than that specified in this manual, the device safety protections may not be effective.
INTRODUCTION
Some of the main challenges for electric power distribution companies involve uninterrupted power supply and the need to meet the requirements of regulatory agencies regarding the quality of electricity supply.
Therefore, it is necessary to monitor the most critical components of power substations to ensure their integrity.
Since an unusual temperature rise can be seen as an early warning indicator of anomaly or asset degradation, NOVUS has launched the Telik Gardo kit, a remote temperature monitoring system that allows you to view information online and manage the maintenance process.
Using wireless temperature sensors, Telik Gardo Reader is easy to install and deploy. It can be integrated into any SCADA system or any cloud platform using an IoT Gateway.
DEVICE
This is the Telik Gardo Reader:
Ideal for DIN rail installation, the device allows you to collect data, read temperature information, and perform continuous monitoring of power substations.
ANTENNA
This is the Telik Gardo Antenna:
The antenna must be attached to the wall by using two screws or connected to the surface by using the magnets. Connected to the antenna, you must install the Telik Gardo Cable, which is 3 meters long.
SENSORS
These are the Telik Gardo Sensors:
The sensors must be installed close to the place to be monitored, fixed with a screw or cable ties. Since they are passive sensors, they do not require batteries.
INSTALLATION
ELECTRICAL INSTALLATION
- INSTALLATION RECOMMENDATIONS
- Electronic and analog signal conductors must run through the plant separately from the output and supply conductors. If possible, in grounded conduits.
- The power supply for the electronic instruments must come from a proper instrumentation network.
- It is recommended to use RC FILTERS (noise suppressors) at contactor coils, solenoids, etc.
- In control applications, it is essential to consider what can happen when any part of the system fails. The internal devices of the equipment do not guarantee full protection.
- The electrical connections must be made with the connection terminals detached from the equipment. Before connecting them, make sure that the connections have been made correctly.
- POWER SUPPLY CONNECTIONS
You must connect the source to the device, using the following identification:
DIMENSIONS
- TELIK GARDO
The device has the following dimensions: - TELIK GARDO ANTENNA
The antenna has the following dimensions: - TELIK GARDO SENSOR
The sensor has the following dimensions:
MECHANICAL INSTALLATION
Telik Gardo Reader is intended for a 35 mm DIN rail mounting. You should use the fixing holes or the magnets to attach your antennas to the wall or desired surface. You can attach the sensors to the electrical panel or surface by using a screw or cable ties.
COMMUNICATION INTERFACES
- USB INTERFACE
Telik Gardo Reader has a USB interface, located on the side of the device. The USB interface must be used to configure and perform device diagnostics via Telik Gardo software. To connect the device to a computer, you must use a micro-USB standard USB cable (not supplied).
Before installing the configuration software, you must install the USB interface drivers (see HOW TO INSTALL THE CONFIGURATION SOFTWARE chapter).
The USB interface should be used temporarily to CONFIGURE and PERFORM DIAGNOSTICS of the device. - RS485 INTERFACE
Telik Gardo Reader has a RS485 interface, located on the side of the device. The RS485 interface can be configured to operate at the following speeds (Baud Rates): 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. In addition, it can be configured to operate with 1 or 2 Stop Bits and in the parities 8N1, 8N2, 8O1, or 8E1. All these parameters can be configured through the software.
The table below helps you to perform the RS485 communication interface connection:
More details on implementing a device network via RS485 can be found in the document “RS485 and RS422 basics”, available at www.novusautomation.com.
HOW TO INSTALL THE CONFIGURATION SOFTWARE
Telik Gardo Reader is compatible with the Telik Gardo software, used to configure and monitor the device. To use it, you must follow the steps below.
- INSTALL THE USB DRIVER
Install the USB driver to enable the computer you are using to recognize Telik Gardo Reader via the USB interface.
Simply double-click the file CP210x_Universal_Windows_Driver, available for download from NOVUS’ product page. To complete the installation, follow the instructions that will appear on the screen. - INSTALL THE CONFIGURATOR SOFTWARE
Install Telik Gardo software to configure and perform data reading from Telik Gardo Reader. The software is compatible with Windows 10 and later versions.
Simply double-click the file Reader_UT_4.0.3_Setup_NOVUS, available for download from NOVUS’ product page. To complete the installation, follow the instructions that will appear on the screen. - CONNECT THE DEVICE TO THE COMPUTER
Once the USB driver for the Telik Gardo Reader and the configuration software has been installed, you can configure the device. Then you should follow the steps below:- Connect the Telik Gardo Reader to a power supply (for more information about the power supply and voltage ranges, see TECHNICAL SPECIFICATIONS chapter).
- Connect the device to mains power. The power indicator light on the device should light up and flash at intervals.
- After installing the USB driver for the device, connect the USB cable from Telik Gardo Reader to the computer’s USB interface.
- Run the Telik Gardo software.
The figure below shows the communication and power interfaces of the device:
HOW TO USE TELIK GARDO SOFTWARE
SOFTWARE INITIAL RUN
- To run Telik Gardo software, double-click the following shortcut icon on your computer desktop:
- After starting the software, open the Windows “Device Manager”. Check the Ports (COM & LPT) section. In it, find the Silicon Labs CP210X USB to UARTBridge (COMX) device.
- Select the USB COMX port and click Open:
- The following window will be displayed:
Make sure that the parameter FW Ver. displays the version number. The example above shows a situation where Telik Gardo Reader is properly connected. - Click the Start button. The software will display messages regarding the scanning of the sensors connected to the reader:
If displayed, the message “Timeout” indicates that communication between the device and the software was unsuccessful. This does not stop the device from working but indicates that it is busy and is in No_Resp mode.
TELIK GARDO SOFTWARE INTERFACE
Once opened, the Telik Gardo software will display the following interface:
This interface is divided into the following sections:
- SOFTWARE VERSION
The software version is displayed at the top of the window:
For software updates, check NOVUS website periodically. - PANEL WITH CONFIGURATION FUNCTIONS
These are the tabs with configuration functions:- Temp 1: Displays information about the sensor status and the sensor notification panel.
- SensorID P1: Allows you to enable or disable sensors and sensor identification settings. For more information, see HOW TO CONFIGURE THE P1 SENSORID INTERFACE section.
- Basic Settings: Allows you to configure the address and put the panel in test mode. For more information, see HOW TO PERFORM A BASIC CONFIGURATION section.
- Antenna Settings: Allows you to enable or disable the antenna. For more information, see HOW TO CONFIGURE THE ANTENNAS section.
- DISPLAYING TEMPERATURE DATA FOR THE SENSOR
This section displays the temperature data from the sensor used:
In addition to the temperature value, the software can also display the following messages:- When the warning “Reading Failed” is displayed: There has been a failure to read the temperature.
- When the warning “Not configured” is displayed: The sensor ID has not been set.
- When the warning “Disabled” is displayed: This sensor has been disabled.
- When “—” is displayed: Software still in boot process. The software has not received any temperature readings.
- When the warning “ANT Disabled” is displayed: The antenna to read the sensor has been disabled.
- SELECTION OF THE RELATED USB COMMUNICATION PORT
You can select which USB port to use:
You can find the computer’s COM port under “Control Panel” → “Device Manager” → “Silicon Labs CP210x USB to UART Bridge Port”.- Open/Close button: Allows you to start/stop the connection with the reader. For more information about the USB interface, see USB INTERFACE section.
- REAL-TIME DATA COLLECTION FUNCTION
By clicking on the Open log folder button, you can view the folder created for saving information about the data collection:
The “T_Log” folder will be created when you first use the software (at reading temperature). By double-clicking Open log folder and choosing the “3.0” folder within it, you can find the log file of the reading.
Each reading will generate a document, as shown in the figure below. The file will be named after the reading has been stopped.
File description:- Text file “Export_Parameter_(Time)”: Log file for reader parameters at the beginning of the reading.
- CSV file “Log_(Time)”: Real-time log file for reading temperatures, antenna signal, etc.
- FIRMWARE VERSION
This section displays the firmware version of the device:
Field description:- RF: Refers to the Radio Module.
- uC: Refers to the Control Module.
When installing a new control module firmware, you should test its compatibility with the Telik Gardo software version. This will prevent errors in the device.
Check NOVUS website periodically for firmware updates.
- START/STOP SENSOR READING
This button is used to start or stop the sensor reading:
HOW TO CONFIGURE THE P1 SENSORID INTERFACE
This section displays instructions on how to assign an ID for the sensor read by Telik Gardo Reader. The sensor settings will be visible when the read function is enabled to request signals from Telik Gardo Reader.
To do this, you must click on the SensorID P1 tab of the configuration software, as shown in the figure below:
Then you should follow the steps below:
- Select the sensors to be read by the device:
- Define an ID and a description for the sensor:
Field description:- Desc: Allows you to enter a description for the sensor. You can use letters and numbers (Example: X33A).
- Sensor ID: Allows you to enter an ID for the sensor. You can enter numbers and upper-case and lower-case letters.
Advanced Function: After defining the sensor ID, you can double-click on the text in the “Sensor ID” field. This allows you to copy the information from the Sensor ID column to the Desc column.
- Set the antenna port for the sensor (ANT 1 ~ ANT 4):
You must configure the antenna according to the field tests previously performed. Each sensor can have a maximum of 2 antennas. - Use the Read and Write buttons to set the parameters. The Read button allows you to get the current configuration parameters. The Write button allows you to overwrite and update the Telik Gardo Reader settings with the defined parameters.
- You can use the Read All and Write All buttons (located in the upper right corner of this tab) to get or set all the configuration parameters.
- You can use the Enable All Sensors and Disable All Sensors buttons to enable or disable all sensors at once.
- You can use the Load and Export buttons to load or export the function list.
- You can use the Read All and Write All buttons to collect or configure all sensor information at once.
HOW TO PERFORM A BASIC CONFIGURATION
This section displays information on how to configure a slave for the Modbus communication protocol (Telik Gardo Reader for master device). To do this, you must click on the Basic Settings tab, as shown in the figure below:
On this screen, you must configure the parameters of the RS485 interface:
You must choose the desired settings from the options for each parameter. The Read button allows you to overwrite the data. The Write button allows you to get the current parameters.
Parameter description:
- Slave address: Allows you to define the slave address to be used.
- Baud Rate: Allows you to define the Baud Rate to be used.
- Parity: Allows you to define the parity, data length and Stop Bits.
For more information about the RS485 interface, see RS485 INTERFACE section.
HOW TO CONFIGURE THE ANTENNAS
This section presents instructions on how to enable or disable the antenna ports of Telik Gardo Reader. To do this, you must click on the Antenna Settings tab, as shown in the figure below:
Then you should follow the steps below:
- Enable the desired antenna (ANT 1 ~ ANT 4):
The ANT 1 ~ ANT 4 options do not appear until the COM port is enabled. - Use the Read and Write buttons to get or set all the configuration parameters.
HOW TO USE THE TOOLBAR
- TOOLBAR
This is the toolbar:
Icon Description: - RF CTRL INTERFACE INSTRUCTIONS
You must click on theicon to open the RF CTRL interface, as shown in the figure below:
- FIRMWARE DOWNLOAD INTERFACE INSTRUCTIONS
You must click theicon to open the interface for downloading the module or base board firmware, as shown in the figure below:
Then you should follow the steps below:- Select the firmware to upgrade and click Select FW File. This will allow you to choose the destination folder:
Files description:- RF Firmware: TGModulo_V4.XX…. bin file to update the RF Module firmware.
- Motherboard firmware: TGPlacaMae_FW_P8… bin file for updating the motherboard firmware.
- The update should proceed after choosing the firmware file. The loading bar indicates the progress of the process:
- After the update has been completed, Windows will display the following pop-up:
During the upgrade process, do not disconnect the device’s power supply or USB connection cables. Otherwise, there may be a failure during the upgrade, as well as irreversible damage. If something happens, contact Technical Support.
- Select the firmware to upgrade and click Select FW File. This will allow you to choose the destination folder:
MODBUS-RTU PROTOCOL
Telik Gardo Reader is compatible with the Modbus-RTU protocol, a data communication protocol used to connect the device to supervisory control and data acquisition systems (SCADA).
COMMANDS
READ HOLDING REGISTERS – 0x03:
This command can be used to read the value of one or up to a maximum of 125 consecutive registers, according to the Register Table.
REGISTERS TABLE
ADDRESS | DESCRIPTION | UNIT | RANGE |
1300 | Temperature Sensor #1 | 0.1 °C | -400 ~ 1500 |
1301 | Temperature Sensor #2 | 0.1 °C | -400 ~ 1500 |
1302 | Temperature Sensor #3 | 0.1 °C | -400 ~ 1500 |
1303 | Temperature Sensor #4 | 0.1 °C | -400 ~ 1500 |
1304 | Temperature Sensor #5 | 0.1 °C | -400 ~ 1500 |
1305 | Temperature Sensor #6 | 0.1 °C | -400 ~ 1500 |
1306 | Temperature Sensor #7 | 0.1 °C | -400 ~ 1500 |
1307 | Temperature Sensor #8 | 0.1 °C | -400 ~ 1500 |
1308 | Temperature Sensor #9 | 0.1 °C | -400 ~ 1500 |
1309 | Temperature Sensor #10 | 0.1 °C | -400 ~ 1500 |
1310 | Temperature Sensor #11 | 0.1 °C | -400 ~ 1500 |
1311 | Temperature Sensor #12 | 0.1 °C | -400 ~ 1500 |
1312 | Temperature Sensor #13 | 0.1 °C | -400 ~ 1500 |
1313 | Temperature Sensor #14 | 0.1 °C | -400 ~ 1500 |
1314 | Temperature Sensor #15 | 0.1 °C | -400 ~ 1500 |
1315 | Temperature Sensor #16 | 0.1 °C | -400 ~ 1500 |
1316 | Temperature Sensor #17 | 0.1 °C | -400 ~ 1500 |
1317 | Temperature Sensor #18 | 0.1 °C | -400 ~ 1500 |
1318 | Temperature Sensor #19 | 0.1 °C | -400 ~ 1500 |
1319 | Temperature Sensor #20 | 0.1 °C | -400 ~ 1500 |
1320 | Temperature Sensor #21 | 0.1 °C | -400 ~ 1500 |
1321 | Temperature Sensor #22 | 0.1 °C | -400 ~ 1500 |
1322 | Temperature Sensor #23 | 0.1 °C | -400 ~ 1500 |
1323 | Temperature Sensor #24 | 0.1 °C | -400 ~ 1500 |
1324 | Temperature Sensor #25 | 0.1 °C | -400 ~ 1500 |
1325 | Temperature Sensor #26 | 0.1 °C | -400 ~ 1500 |
1326 | Temperature Sensor #27 | 0.1 °C | -400 ~ 1500 |
1327 | Temperature Sensor #28 | 0.1 °C | -400 ~ 1500 |
1328 | Temperature Sensor #29 | 0.1 °C | -400 ~ 1500 |
1329 | Temperature Sensor #30 | 0.1 °C | -400 ~ 1500 |
1330 | Temperature Sensor #31 | 0.1 °C | -400 ~ 1500 |
1331 | Temperature Sensor #32 | 0.1 °C | -400 ~ 1500 |
1332 | Temperature Sensor #33 | 0.1 °C | -400 ~ 1500 |
1333 | Temperature Sensor #34 | 0.1 °C | -400 ~ 1500 |
1334 | Temperature Sensor #35 | 0.1 °C | -400 ~ 1500 |
1335 | Temperature Sensor #36 | 0.1 °C | -400 ~ 1500 |
ADDRESS | DESCRIPTION | UNIT | RANGE |
1336 | Temperature Sensor #37 | 0.1 °C | -400 ~ 1500 |
1337 | Temperature Sensor #38 | 0.1 °C | -400 ~ 1500 |
1338 | Temperature Sensor #39 | 0.1 °C | -400 ~ 1500 |
1339 | Temperature Sensor #40 | 0.1 °C | -400 ~ 1500 |
1340 | Temperature Sensor #41 | 0.1 °C | -400 ~ 1500 |
1341 | Temperature Sensor #42 | 0.1 °C | -400 ~ 1500 |
1342 | Temperature Sensor #43 | 0.1 °C | -400 ~ 1500 |
1343 | Temperature Sensor #44 | 0.1 °C | -400 ~ 1500 |
1344 | Temperature Sensor #45 | 0.1 °C | -400 ~ 1500 |
1345 | Temperature Sensor #46 | 0.1 °C | -400 ~ 1500 |
1346 | Temperature Sensor #47 | 0.1 °C | -400 ~ 1500 |
1347 | Temperature Sensor #48 | 0.1 °C | -400 ~ 1500 |
RELATIVE HUMIDITY INFORMATION (OPTIONAL)
ADDRESS | DESCRIPTION | UNIT | RANGE |
1491 | Room temperature 1 | 0.1 °C | -400 ~ 1500 |
1492 | Humidity 1 | 0.1 % | 0 ~ 999 |
1493 | Dew point 1 | 0.1 °C | -400 ~ 1500 |
1494 | Room temperature 2 | 0.1 °C | -400 ~ 1500 |
1495 | Humidity 2 | 0.1 % | 0 ~ 999 |
1496 | Dew point 2 | 0.1 °C | -400 ~ 1500 |
1497 | Room temperature 3 | 0.1 °C | -400 ~ 1500 |
1498 | Humidity 3 | 0.1 % | 0 ~ 999 |
1499 | Dew point 3 | 0.1 °C | -400 ~ 1500 |
TECHNICAL SPECIFICATIONS
FEATURES | TELIK GARDO READER |
Operating temperature | -20 to 70 °C (-4 to 158 °F) |
Frequency range | 920 MHZ – 925 MHZ |
Antenna ports | 4 ports |
Range / Receive range | Up to 2 meters, depending on the position of the antenna and sensor. |
Dimensions | 80 x 45 x 118 mm |
Communication interfaces | USB 2.0 Interface
RS485 Communication Interface with Modbus-RTU protocol |
Power supply | 100 ~ 240 V (±10 %) |
Software | Telik Gardo Software |
Certifications | Anatel (01031-22-11205), FCC, CE, UKCA |
FEATURES | TELIK GARDO ANTENNA |
Connector | SMA Male |
Dimensions | 46.5 x 21.1 x 22.2 mm |
Installation type | Assemble with magnet or screw. |
Operating temperature | -20 to 85 °C (-4 to 185 °F) |
Polarization | Circular |
Antenna gain | 3 dbi |
Protection Index | IP54 |
FEATURES | TELIK GARDO SENSOR |
Accuracy | ± 2 °C (± 3.6 °F) |
Dimensions | 69 x 27 x 23 mm |
Installation type | Screw or clamp |
Reading range | 2-3 meters |
Operating temperature | -20 to 125 °C (-4 to 257 °F) |
Measurement range | -20 to 125 °C (-4 to 257 °F) |
Protection index | IP30 |
Maximum monitored line voltage | 40 kV |
CERTIFICATIONS
ANATEL
This device is homologated by ANATEL, according to the regulated procedures for conformity assessment of telecommunications products, and meets the technical requirements applied.
This equipment is not subject to protection from harmful interference and may not cause interference with duly authorized systems.
For more information, see ANATEL website: www.anatel.gov.br.
FCC
FCC ID: 2A3F5PQS-RD-01
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
RF Exposure: To meet the FCC RF exposure requirements for mobile and base station transmission, a separation distance of 6.5 cm or more must be maintained between the antenna of this device and people during operation. To ensure compliance, it is not recommended to operate at a closer distance. The antennas used for this transmitter must not coincide or operate with any other antenna or transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CE Mark / UKCA
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
WARRANTY
Warranty conditions are available on our website www.NOVUSautomation.com/warranty.
Documents / Resources
![]() |
novus V1.0x C Telik Gardo Reader [pdf] User Guide V1.0x C Telik Gardo Reader, V1.0x C, Telik Gardo Reader, Gardo Reader, Reader |