NOVASTAR COEX Series Controller Control System

NOVASTAR-COEX-Series-Controller-Control-System-PRODUCT

Product Information

Specifications

  • Product Type: LED display controller Software
  • Applicable Models:
    • Single-card controllers: MX40 Pro, MX30, MX20, KU20
    • Card-based controllers: MX6000 Pro, CX40 Pro
  • Version: V1.4.0

FAQ

Q: What is SNMP?

A: SNMP (Simple Network Management Protocol) is a protocol used for network management and monitoring.

Q: How do I know if my device supports SNMP?

A: Refer to the product manual or contact customer support to confirm SNMP support for your device.

Applicable Products

Product Type Model Version
LED display controller Single-card controllers: MX40 Pro, MX30, MX20, KU20 Card-based controllers: MX6000 Pro, CX40 Pro V1.4.0
Software VMP V1.4.0

Function Scope

The following operations can be performed through SNMP:

  • Controller information obtaining
  • Screen information obtaining
  • Cabinet information obtaining
  • Controller status obtaining and reporting
  • Input source status obtaining and reporting
  • Ethernet port status obtaining and reporting
  • Receiving card status obtaining and reporting
  • SNMP reporting target server (ip/port number 162)
  • SNMP reporting period (range: 1-60, unit: minute)

Operating Procedure

Each function corresponds to an OID, which is used to distinguish different monitoring items. When testing through the MIB software, enter the corresponding OID to get the corresponding monitoring item, enter the reporting OID to receive the trap information, and enter the reporting time OID to set the trap period. Specific operations are as follows:

Enable SNMP via Controllers

Single-card Controllers
Single-card controllers include MX40 Pro, MX30, MX20, KU20

  • Step 1 On the main menu screen, choose Communication Settings > Network Settings.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-1
  • Step 2 Toggle on or off SNMP.
    • NOVASTAR-COEX-Series-Controller-Control-System-FIG-2: Enable SNMP.
    • NOVASTAR-COEX-Series-Controller-Control-System-FIG-3: Disable SNMP.

Card-based Controllers
Card-based controllers include MX6000 Pro and MX2000 Pro.

  • Step 1 Select Communication > Protocol from the main menu to access the settings interface.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-4
  • Step 2 Toggle on or off SNMP.
    • NOVASTAR-COEX-Series-Controller-Control-System-FIG-2: Enable SNMP.
    • NOVASTAR-COEX-Series-Controller-Control-System-FIG-3: Disable SNMP.

Retrieve Monitoring Information via a Get Request

  • Step 1 Open the MIB Browser to enter the software interface.
  • Step 2 By following the arrows in the figure below in order, fill in the correct device IP address and the OID corresponding to the monitoring item information in the picture, select Get in the Operations drop-down list, and finally click the Go button to complete the operation of getting the monitoring item information by Get.
  • Step 3 The execution results are displayed in the Result Table area, and the information contains the OID address, the results of the monitored items returned, the data type and the device IP, as shown in the figure.

    NOVASTAR-COEX-Series-Controller-Control-System-FIG-5

  • Step 4 The rest of the monitoring information can be obtained directly by selecting the Get Next option in the Operations drop-down list and clicking the Go button, as shown in the figure below.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-6

Get Trap Reporting Information

  • Step 1 Open the MIB Browser to enter the software interface.
  • Step 2 Fill in the correct device IP address and the OID corresponding to the monitoring item information at the top of the page, select Set in the Operations drop-down list and click the Go button.
  • Step 3 In the OID input box of the pop-up SNMP SET edit area, fill in .1.3.6.1.4.1.319.2.100.0.1, select the corresponding type OctetString of the parameter to be sent in the Data Type drop-down list, and fill in the parameter value 172.17.6.179/162 (local IP/162) in the Value input box.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-7
  • Step 4 Click the OK button to complete the SNMP Trap server setup operation.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-8
  • Step 5 Click on the Tools option in the menu bar of the software and select the Trap Receiver option in the dropdown menu that opens to complete the operation of getting information of monitoring items by Trap.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-9
  • Step 6 The execution results are displayed in the Trap Receiver area, as shown in the figure. Detailed information can be viewed in the details display area below by clicking on the specific entry in the Description.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-10

Perform the Operation of Reporting Target Settings

  • Step 1 Open the MIB Browser to enter the software interface.
    Step 2 Fill in the correct device IP address and the OID corresponding to the monitoring item information at the top of the page, select Set in the Operations drop-down list and Click the Go button.
  • Step 3 Fill in the correct OID in the OID input box of the pop-up SNMP SET edit area, select the corresponding type of the parameter to be sent in the Data Type drop-down list, and fill in the parameter value in the Value input box. After that, click the OK button to complete the report target setting operation.
    NOVASTAR-COEX-Series-Controller-Control-System-FIG-11

Examples

Demonstration software: MIB software (software disadvantage: not supporting the display of uint64 type data)

Get example
When testing the connection status of receiving cards 1-64 under Ethernet port 1, the value obtained is -1.
The MIB software will treat the highest bit as a symbolic bit and all get or trap data in int64 type will be in this situation. At this time, use wireshark to capture packet for test:

NOVASTAR-COEX-Series-Controller-Control-System-FIG-12 NOVASTAR-COEX-Series-Controller-Control-System-FIG-13

Trap example

To test the connection status change of receiving cards 1- 64 under Ethernet port 1, you can manually unplug and then plug the receiving cards to cause changes.

Set example
Set the reporting period to 5 minutes, as follows (MIB software):

NOVASTAR-COEX-Series-Controller-Control-System-FIG-14

COEX Series Controller and SNMP OID Parameter Comparison

N in the OID denotes a numerical value and takes a value in the range of 1 to the maximum value of the quantity (the maximum value of the quantity is obtained by the corresponding OID).

SNMP GET (Read-only)

Controller Information

Function OID Data Type Controller Type Description
Controller time and date  

1.3.6.1.4.1.319.10.10.1.1

 

string

Single-card & Card-based  

2006/01/03 15:04:05

 

Controller model

 

1.3.6.1.4.1.319.10.10.1.2

 

string

Single-card & Card-based  

\

Controller firmware version  

1.3.6.1.4.1.319.10.10.1.3

 

string

Single-card & Card-based  

\

 

Controller name

 

1.3.6.1.4.1.319.10.10.1.4

 

string

Single-card & Card-based  

\

Controller primary/backup status  

1.3.6.1.4.1.319.10.10.1.5

 

int

Single-card & Card-based  

0: primary; 1: backup

Controller serial number  

1.3.6.1.4.1.319.10.10.1.6

 

string

Single-card & Card-based  

\

Controller MAC address  

1.3.6.1.4.1.319.10.10.1.7

 

string

Single-card & Card-based  

\

 

Controller IP address

 

1.3.6.1.4.1.319.10.10.1.8

 

string

Single-card & Card-based  

192.168.12.34

Controller Status

Function OID Data Type Controller Type Description
Number of mainboard temperature measurement points  

1.3.6.1.4.1.319.10.10.10.

1

 

int

Single-card & Card-based  

N ≥ 0

Name of mainboard temperature measurement point N  

1.3.6.1.4.1.319.10.10.10.

2.N.1

 

string

Single-card & Card-based  
Status of mainboard temperature measurement point N  

1.3.6.1.4.1.319.10.10.10.

2.N.2

 

int

Single-card & Card-based Normal: 0

Abnormal: 1

Value of mainboard temperature measurement point N  

1.3.6.1.4.1.319.10.10.10.

2.N.3

 

int

Single-card & Card-based  
Number of mainboard voltage measurement points  

1.3.6.1.4.1.319.10.10.10.

3

 

int

Single-card & Card-based  
Name of mainboard voltage measurement point N  

1.3.6.1.4.1.319.10.10.10.

4.N.1

 

string

Single-card & Card-based  
Status of mainboard voltage measurement point N  

1.3.6.1.4.1.319.10.10.10.

4.N.2

 

int

Single-card & Card-based Normal: 0

Abnormal: 1

Value of mainboard voltage measurement point N  

1.3.6.1.4.1.319.10.10.10.

4.N.3

 

int

Single-card & Card-based  
 

Number of fans

1.3.6.1.4.1.319.10.10.10.

5

 

int

Single-card & Card-based  
 

Name of fan N

1.3.6.1.4.1.319.10.10.10.

6.N.1

 

string

Single-card & Card-based  
 

Status of fan N

1.3.6.1.4.1.319.10.10.10.

6.N.2

 

int

Single-card & Card-based Normal: 0

Abnormal: 1

Rotating speed of fan N 1.3.6.1.4.1.319.10.10.10.

6.N.3

 

int

Single-card & Card-based  
Number of controller power supplies 1.3.6.1.4.1.319.10.10.10.

7

 

int

Single-card & Card-based  
Status of controller power supply N 1.3.6.1.4.1.319.10.10.10.

8.N.1

 

int

Single-card & Card-based Not inserted: 0

Inserted: 1

Genlock connection status 1.3.6.1.4.1.319.10.10.10.

9.1

 

int

Single-card & Card-based Not connected: 0

Connected: 1

 

Genlock frame rate

1.3.6.1.4.1.319.10.10.10.

9.2

 

int

Single-card & Card-based  

Output Card Slot Information

Function OID Data Type Controller Type Description
 

Number of output card slots (N)

 

1.3.6.1.4.1.319.10.10.30.

1

 

 

int

 

Single-card & Card-based

N ≥ 0

Single-card controller: N = 1 (The number of output card slots for a single-card

        controller is always 1)
Output card slot status 1.3.6.1.4.1.319.10.10.30.

2

 

int

Single-card & Card-based Connected: 0

Disconnected: 1

Card firmware version of output card slot N 1.3.6.1.4.1.319.10.10.30.

3.N.1

 

Counter64

Single-card & Card-based  
Card name of output card slot N 1.3.6.1.4.1.319.10.10.30.

3.N.2

 

string

Single-card & Card-based  
 

Card primary/backup status of output card slot N

 

1.3.6.1.4.1.319.10.10.30.

3.N.3

 

 

string

 

Single-card & Card-based

0x4D 58 5F 34 C3 97 31 30

47

5F 46 69 62 65 72 20 6F 75

74

70 75 74 20 63 61 72 64

Card SN of output card slot N 1.3.6.1.4.1.319.10.10.30.

3.N.4

 

int

Single-card & Card-based 0: primary

1: backup

Output Card Slot Status

Function OID Data Type Controller Type Description
Number of card temperature measurement points

(Y) of output card slot N

 

1.3.6.1.4.1.319.10.10.30.

4.N.1

 

 

string

 

 

Card-based

 

Y ≥ 0

Name of temperature measurement point Y of output card slot N 1.3.6.1.4.1.319.10.10.30.

4.N.2.Y.1

 

int

 

Card-based

 
Temperature status of temperature measurement point Y of output card slot N  

1.3.6.1.4.1.319.10.10.30.

4.N.2.Y.2

 

string

 

Card-based

 

0: Normal

1: Abnormal

Temperature of temperature measurement point Y of output card slot N  

1.3.6.1.4.1.319.10.10.30.

4.N.2.Y.3

 

int

 

Card-based

 
Number of card voltage measurement points of output card slot N  

1.3.6.1.4.1.319.10.10.30.

4.N.3

 

int

 

Card-based

 
Name of voltage measurement point Y of output card slot N 1.3.6.1.4.1.319.10.10.30.

4.N.4.Y.1

 

int

 

Card-based

 
Voltage status of voltage measurement point Y of output card slot N  

1.3.6.1.4.1.319.10.10.30.

4.N.4.Y.2

 

string

 

Card-based

 

0: Normal

1: Abnormal

Voltage of voltage measurement point Y of output card slot N 1.3.6.1.4.1.319.10.10.30.

4.N.4.Y.3

 

int

 

Card-based

 
Number of card Ethernet ports of output card slot N 1.3.6.1.4.1.319.10.10.30.

5.N.1

 

int

Single-card & Card-based  
Connection speed of card Ethernet ports of output card slot N 1.3.6.1.4.1.319.10.10.30.

5.N.2

 

int

Single-card & Card-based  
Connection status of card Ethernet ports of 1.3.6.1.4.1.319.10.10.30.

5.N.3

 

int

Single-card & Card-based 0: Normal

1: Abnormal

output card slot N        
Number of online receiving cards of Ethernet port Y of output card slot N  

1.3.6.1.4.1.319.10.10.30.

5.N.4.Y.1

 

Counter64

 

Single-card & Card-based

 
Temperature status of receiving card M of Ethernet port Y of output card slot N  

1.3.6.1.4.1.319.10.10.30.

6.N.1.Y.1.M

 

int

 

Single-card & Card-based

 

0: Normal

1: Abnormal

Voltage status of receiving card M of Ethernet port Y of output card slot N  

1.3.6.1.4.1.319.10.10.30.

6.N.1.Y.2.M

 

Counter64

 

Single-card & Card-based

 

0: Normal

1: Abnormal

Screen Information

Function OID Data Type Controller Type Description
 

 

Number of screens (N)

 

 

1.3.6.1.4.1.319.10.20.1.1

 

 

int

 

 

Single-card & Card-based

N ≥ 0

Single-card controller: N = 1

(The number of screens for a single-card controller is always 1)

 

Name of screen N

1.3.6.1.4.1.319.10.20.1.2. N.1  

string

Single-card & Card-based  
 

Width of screen N

1.3.6.1.4.1.319.10.20.1.2. N.2  

int

Single-card & Card-based  
 

Height of screen N

1.3.6.1.4.1.319.10.20.1.2. N.3  

int

Single-card & Card-based  
Frame rate of screen N 1.3.6.1.4.1.319.10.20.1.2. N.4  

int

Single-card & Card-based  
Brightness of screen N 1.3.6.1.4.1.319.10.20.1.2. N.5  

string

Single-card & Card-based  
 

Sync type of screen N

 

1.3.6.1.4.1.319.10.20.1.2. N.6

 

int

 

Single-card & Card-based

0: Current video source 1: Genlock

2: Internal

Sync frame rate of screen N 1.3.6.1.4.1.319.10.20.1.2. N.7  

int

Single-card & Card-based  

Note: The “Brightness of screen N” is a read-write information

Input Card Slot Information

Function OID Data Type Controller Type Description
 

 

Number of input card slots (N)

 

 

1.3.6.1.4.1.319.10.10.20.

1

 

 

int

 

 

Single-card & Card-based

N ≥ 0

Single-card controller: N = 1

(The number of input card slots for a single-card controller is always 1)

 

Input card slot status

1.3.6.1.4.1.319.10.10.20.

2

 

Counter64

Single-card & Card-based  
Card firmware version of input card slot N 1.3.6.1.4.1.319.10.10.20.

3.N.1

 

string

Single-card & Card-based  
Card name of input card slot N 1.3.6.1.4.1.319.10.10.20.

3.N.2

 

string

Single-card & Card-based  
Card primary/backup status of input card slot N 1.3.6.1.4.1.319.10.10.20.

3.N.3

 

int

Single-card & Card-based 0: Primary

1: Backup

Card SN of input card slot N 1.3.6.1.4.1.319.10.10.20.

3.N.4

 

string

Single-card & Card-based  

Input Card Slot Status

Function OID Data Type Controller Type Description
Number of card temperature measurement points

(Y) of input card slot N

 

1.3.6.1.4.1.319.10.10.20.

4.N.1

 

 

int

 

 

Card-based

 

Y ≥ 0

Name of temperature measurement point Y of input card slot N 1.3.6.1.4.1.319.10.10.20.

4.N.2.Y.1

 

string

 

Card-based

 
Temperature status of temperature measurement point Y of input card slot N  

1.3.6.1.4.1.319.10.10.20.

4.N.2.Y.2

 

int

 

Card-based

 

0: Normal

1: Abnormal

Temperature of temperature measurement point Y of input card slot N  

1.3.6.1.4.1.319.10.10.20.

4.N.2.Y.3

 

int

 

Card-based

 
Number of card voltage measurement points of input card slot N  

1.3.6.1.4.1.319.10.10.20.

4.N.3

 

int

 

Card-based

 
Name of voltage measurement point Y of input card slot N 1.3.6.1.4.1.319.10.10.20.

4.N.4.Y.1

 

string

 

Card-based

 
Voltage status of voltage measurement point Y of input card slot N  

1.3.6.1.4.1.319.10.10.20.

4.N.4.Y.2

 

int

 

Card-based

 

0: Normal

1: Abnormal

Voltage of voltage measurement point Y of input card slot N 1.3.6.1.4.1.319.10.10.20.

4.N.4.Y.3

 

int

 

Card-based

 

Input Source Information

Function OID Data Type Controller Type Description
Number of card input sources of input card slot (N) 1.3.6.1.4.1.319.10.10.20.

5.N.1

 

int

Single-card & Card-based  

N ≥ 0

Signal status of input source Y of input card slot N 1.3.6.1.4.1.319.10.10.20.

5.N.2.Y.1

 

int

Single-card & Card-based 0: Not inserted

1: Signal available

2: Inserted but no signal

 

 

Type of input source Y of input card slot N

 

 

1.3.6.1.4.1.319.10.10.20.

5.N.2.Y.2

 

 

string

 

 

Single-card & Card-based

0: DVI

1: DualDVI

2: HDMI1.4

3: HDMI2.0

4: DP1.1

        5: DP1.2

6: DP1.4

7: 3G-SDI

8: 6G-SDI

9: 12G-SDI

10: PIP Video

16: HDMI1.3

17: HDMI2.1

18: PCIE

19: Serdes

20: LVDS

21: VByOne

22: ST 2110

224: internal-source Other value: Unknown

Application status of input source Y of input card slot N 1.3.6.1.4.1.319.10.10.20.

5.N.2.Y.3

 

int

Single-card & Card-based 0: Normal

2: Abnormal

Internal Source Information

Function OID Data Type Controller Type Description
Number of internal sources (N) 1.3.6.1.4.1.319.10.10.50.

1

 

int

Single-card & Card-based N ≥ 1
Number of screens applying internal source N 1.3.6.1.4.1.319.10.10.50.

2.N.1

 

int

Single-card & Card-based 0: Not applied

1: Applied

Link status of internal source N 1.3.6.1.4.1.319.10.10.50.

2.N.2

 

int

Single-card & Card-based 0: Not inserted

1: Signal available

2: Inserted but no signal

SNMP TRAP Reporting

Output Anomaly Reporting

Function OID Data Type Controller Type Description
Index of abnormal output card slot 1.3.6.1.4.1.319.10.120.N. Y  

int

Single-card & Card-based  

 

 

 

 

N: Output card slot N

Single-card controller: N = 1

(The number of output card slots for a single-card controller is always 1)

Y: Output card temperature, voltage, fan

Number of Ethernet port connections 1.3.6.1.4.1.319.10.120.N.

4

 

int

Single-card & Card-based
Number of receiving cards connected of Ethernet port Y of output card slot N  

1.3.6.1.4.1.319.10.120.N. Y.5

 

int

 

Single-card & Card-based

Number of receiving cards with abnormal temperature of Ethernet port Y of output card slot N  

1.3.6.1.4.1.319.10.120.N. Y.6

 

 

int

 

Single-card & Card-based

Number of receiving cards with abnormal voltage of Ethernet port Y of output card slot N  

1.3.6.1.4.1.319.10.120.N. Y.7

 

 

int

 

Single-card & Card-based

Screen Information Reporting

Function OID Data Type Controller Type Description
Number of receiving cards connected of screen N 1.3.6.1.4.1.319.10.130.N.

1

 

int

Single-card & Card-based  
Number of receiving cards with abnormal temperature of screen N  

1.3.6.1.4.1.319.10.130.N.

2

 

int

 

Single-card & Card-based

 
Number of receiving cards with abnormal voltage of screen N 1.3.6.1.4.1.319.10.130.N.

3

 

int

Single-card & Card-based  

Controller Information Reporting

Function OID Data Type Controller Type Description
Index of abnormal mainboard item 1.3.6.1.4.1.319.10.100.N int Single-card & Card-based N: controller temperature 1, voltage 2, fan 3
Number of input cards connected 1.3.6.1.4.1.319.10.100.4 int Single-card & Card-based  
Number of output cards connected 1.3.6.1.4.1.319.10.100.5 int Single-card & Card-based  
Number of expansion cards connected 1.3.6.1.4.1.319.10.100.6 int Single-card & Card-based  
Genlock connection status 1.3.6.1.4.1.319.10.100.7 int Single-card & Card-based 0: Not connected

1: Connected

SNMP Start Time 1.3.6.1.4.1.319.10.100.8 string Single-card & Card-based  
Index of abnormal input card slot 1.3.6.1.4.1.319.10.110.N. Y  

int

Single-card & Card-based %D: input card slot N %d: input card temperature, voltage, fan
Number of connections of input source N 1.3.6.1.4.1.319.10.110.N.

4

 

int

Single-card & Card-based N: controller temperature 1, voltage 2, fan 3

SNMP SET Read and Write

Function OID Data Type Controller Type Description
 

SNMP Trap server

 

1.3.6.1.4.1.319.10.200.1

 

string

 

Single-card & Card-based

 
SNMP Trap reporting period 1.3.6.1.4.1.319.10.200.2 int Single-card & Card-based  
Temperature Unit 1.3.6.1.4.1.319.10.200.3 int Single-card & Card-based 0: Fahrenheit

1: Celsius

Copyright © 2024 Xi’an NovaStar Tech Co., Ltd. All Rights Reserved.
No part of this document may be copied, reproduced, extracted or transmitted in any form or by any means without the prior written consent of Xi’an NovaStar Tech Co., Ltd.

Trademark
NOVASTAR is a trademark of Xian NovaStar Tech Co., Ltd.

Statement
Thank you for choosing NovaStar’s product. This document is intended to help you understand and use the product. For accuracy and reliability, NovaStar may make improvements and/or changes to this document at any time and without notice. If you experience any problems in use or have any suggestions, please contact us via the contact information given in this document. We will do our best to solve any issues, as well as evaluate and implement any suggestions.