nous D4Z Smart Energy Monitor
Description
The Zigbee NOUS D4Z smart energy monitor is a monitoring device that consists of a 18mm-width (1MW) monitor installed at DIN rail and three split-core current transformers (CTs). Functioning as a professional 3-phase energy meter, it accurately measures real time voltage, current, power and energy data, with wireless and/or wired communication options available for data transmission.
NOTE: You will need a Nous E1, Nous E7 or other Tuya compatible ZigBee gateway/hub to connect.
The connection of a smart socket to the Internet cannot be guaranteed in all cases, as it depends on many conditions: the quality of the communication channel and intermediate network equipment, the make and model of the mobile device, the version of the operating system, etc.
PRECAUTIONS
- Read this manual carefully.
- Use the product within the temperature and humidity limits specified in the technical data sheet
- Do not install the product near heat sources, such as radiators, etc.
- Do not allow the device to fall and be subject to mechanical loads.
- Do not use chemically active and abrasive detergents to clean the product. Use a damp flannel cloth for this.
- Do not overload the specified capacity. This may cause short circuit and electric shock.
- Do not disassemble the product yourself-diagnostics and repair of the device must be carried out only in a certified service center.
Design and controls
№ | Name | description |
1 | Status LED (ACT) | Shows the current status of the device |
2 | Alarm LED (AL) | |
3 | Button | A long press of the button (5-7 C) resets the smart outlet settings and zigbee network connection parameters. |
4 | Split-core CT | Split-core CTs (Detection module) |
Assembly
Install the main part Instalar la parte principal del D4z | ![]() |
Voltage measurement must match current measurement – Vx (Ix) ; Vy (Iy); Vz (Iz), to measure electrical data correctly It can cause product damage, if the blue cable for N connection is connected to phase conductors by mistake. | ![]() |
Install the voltage connector | ![]() |
Install the Current Transformer connector | ![]() |
Install the Current Transformer | ![]() |
NOTICE | To guarantee measurement accuracy it is recommended to keep the conductor adherent to the CT body by two fixing straps, see figure. Assemble correctly the correspondent phase to CT line (e.g. L1 with CT1). |
Connection
To connect the Nous D4Z device, you need a smartphone based on the Android or iOS mobile operating system with the Nous Smart Home application installed. This mobile application is free and available for download from Play Market and App Store. The QR code for the application is given below:
The procedure for connecting the device to the Zigbee network
1 | Connect the smartphone to the access point that will be used to connect the device. Make sure the network frequency range is 2.4 GHz, otherwise the device will not connect, as Zigbee Habs are not designed to work with 5 GHz Wi-Fi networks; (your ZigBee hub should already be connected to the app) |
2 | Connect the device to the network. If the global indication does not flash quickly, then press the button for 5-7 seconds to reset the smart outlet settings to factory values. |
3 | 3 Open the Nous Smart Home app and click the button to add a new device |
4 | An autos can will appear, prompting you to add a new device. Confirm the connection and start pairing. |
5 | If autos can doesn’t see your device, you can select it manually from the list of devices |
![]() |
![]() |
6 | In the “Add Manually” tab, select the “Stnsors” category, and in it the “Zigbee Smart Din Energy Monitor D4Z” model, as shown in the figure above; |
7 | In the window that opens, select “next step” and click the “Next” button; |
8 | connection to the Zigbee hub A window will appear indicating the degree of network connection and adding the current user of the program to the list of devices: |
![]() |
![]() |
9 | After the procedure, a window will appear in which you can set the name of the device and choose the room in which it is located. The device name will also be used by Amazon Alexa and Google Home. |
10 | 10 To delete all data from the smart socket, in the device menu, you need “Delete device”, “disabled and delete all data” |
When the device is removed from the device list of the application user, the settings of the smart socket will be reset to factory values and it will be necessary to shorten the procedure of connecting to the Wi-Fi network again. If the password for the Wi-Fi access point was entered incorrectly, then after the timer expires, a “failed to connect to Wi-Fi” window appears in the application with step-by-step instructions to fix the problem. |
How to connect your device to Alexa
1 | Sign in with your Alexa account and password (if you’re not already signed in, sign up first); After logging in, click the menu in the upper left corner, then click “Settings” and select “Set up a new device”; |
2 | Select “Skills” in the options bar, then search for “NOUS Smart Home” in the search bar; In the search results, select NOUS Smart Home, then click Enable. |
3 | Enter the username and password you previously registered (the account is only supported in the United States); When you see the correct page, it means that your Alexa account is linked to your NOUS Smart Home account. |
![]() |
![]() |
4 | Device discovery: Users must tell Echo, “Echo (or Alexa), open my devices.” Echo will start to find the devices added in NOUS Smart Home APP, it will take about 20 seconds to show the result. Or you can click “Open devices” in Alexa APP, it will show the devices found successfully. Note: “Echo” is one of the wake-up names, which can be any of these three names (Settings): Alexa/Echo/Amazon. |
5 | List of support skills User can control devices with following instructions: Alexa, turn on [device] Alexa, turn off [device] |
Attention: the name of the device must match the NOUS Smart Home APP. |
Documents / Resources
![]() |
nous D4Z Smart Energy Monitor [pdf] Instruction Manual D4Z Smart Energy Monitor, D4Z, Smart Energy Monitor, Energy Monitor |