NORDEN NVS-IP100028AA 4 Channel 2 Way Audio Interface User Manual

NVS-IP100028AA 4 Channel 2 Way Audio Interface

Product Specifications:

Product Overview:

Description:

The NVS-IP100028AA is a 4-channel audio interface with 2-way
communication capabilities.

Features:

  • Main Power Switch
  • Power Switch of Each Module
  • SIGNAL Indicator
  • Alarm Input/Output Interface
  • AUDIO Audio Input/Output Interface
  • Input Volume Adjustment Knob
  • RESET Button for defaults or firmware upgrade
  • LAN Network Interface
  • Power Interface
  • Grounding Switch

Hardware Interface Introduction:

Front Panel:

  • Main Power Switch
  • Power Switch of Each Module
  • SIGNAL Indicator

Rear Panel:

  • Alarm Input/Output Interface
  • AUDIO Audio Input/Output Interface
  • Input Volume Adjustment Knob
  • RESET Button
  • LAN Network Interface
  • Power Interface
  • Grounding Switch

Product Usage Instructions:

Introduction:

The NVS-IP100028AA is designed for audio communication and
requires proper wiring and network settings for operation.

Wiring:

Note: Each module requires independent wiring.

Basic Network Settings:

  1. Connect the necessary cables as per the installation
    manual.
  2. Power on the device and adjust terminal network parameters
    based on the environment.
  3. Select the Mandatory config from the menu and fill in the
    correct parameters in the terminal parameter section. Press send to
    configure IP parameters.
  4. Login to the Web Interface by entering the device’s IP address
    in a browser.

Frequently Asked Questions (FAQ):

Q: What is the default IP address of the NVS-IP100028AA?

A: The default IP address is 192.168.1.101. It will
automatically display when pressing the terminal key without the
cable inserted.

“`

NVS-IP100028AA 4 CHANNEL 2 WAY AUDIO INTERFACE
USER MANUAL
www.nordencommunication.com

1 www.nordencommunication.com

Contents
Product Overview…………………………………………………………………………………………………………. 3 Description………………………………………………………………………………………………………………. 3 Features………………………………………………………………………………………………………………….. 3
Hardware Interface Introduction ……………………………………………………………………………………… 3 Front Panel………………………………………………………………………………………………………………. 3 Rear Panel……………………………………………………………………………………………………………….. 4
Introduction………………………………………………………………………………………………………………… 5 Wiring …………………………………………………………………………………………………………………….. 5 Basic Network Settings……………………………………………………………………………………………….. 5
User-defined Terminal Parameters …………………………………………………………………………………… 7 Login Web Interface…………………………………………………………………………………………………… 7 Network Parameters………………………………………………………………………………………………….. 8 Audio and Alert Parameters…………………………………………………………………………………………. 9 Web Management…………………………………………………………………………………………………… 10 Reboot Device ………………………………………………………………………………………………………… 10 Reset to Defaults …………………………………………………………………………………………………….. 11 Firmware Upgrade …………………………………………………………………………………………………… 11 System Logs……………………………………………………………………………………………………………. 12
Trouble Shooting………………………………………………………………………………………………………… 13
www.nordencommunication.com 2

Product Overview
Description
The NVS-IP100028AA is a 4-channel, 2-way audio interface with a 1U rack-mounted design and an anti-corrosion aluminum alloy panel. It features hardware-based audio encoding and supports 4 alarm inputs and 4 alarm outputs for linkage triggering. The dry-contact outputs can interface with third-party devices for automated online control. Designed for real-time performance, it offers ultra-low voice transmission latency (broadcast delay 30ms). The unit includes a standard RJ45 port, supporting cross-network segment and router communication, ensuring seamless integration over Ethernet-enabled systems.
Features
· 1U rack-mounted design with anti-corrosion aluminum panel · Hardware audio encoding with ultra-low delay (30ms) · Standard RJ45 port supports cross-segment and router networks · 4 independent decoder chips for simultaneous 4-channel decoding · Remote volume adjustment via network for each input channel · 4 relay inputs/outputs for third-party device integration
Hardware Interface Introduction
Front Panel
1. Main Power Switch 2. Power Switch of Each Module 3. SIGNAL Indicator
3 www.nordencommunication.com

When the device is idle, the indicator light is off. When a signal is detected at the line input interface, the light turns orange, with brightness varying according to the audio signal strength–the louder the volume, the brighter the light. 4. STATUS Indicator The status indicator light is solid green when the device is logged into the server, flashes green during broadcasting or firmware upgrade, and remains off when the device is offline. 5. S1 The power indicator light of each module turns green when powered on and turns off when the device is powered down.
Rear Panel
1. Alarm Input/Output Interface
2. AUDIO Audio Input/Output Interface
3. Input Volume Input volume adjustment knob, clockwise increase the volume, counterclockwise reduce the volume.
4. RESET Press the button to reset to defaults (or firmware upgrade), broadcast IP.
www.nordencommunication.com 4

Status

Operation

Mandatory restore IP Press the button with power 3s

address

continuously

Mandatory access firmware upgrade interface

Press the button, and then power the device, hold the button for 5 seconds

Broadcast IP

Power ON, under the situation of network offline, short press the button and release.

5. LAN Network interface
6. Power Interface 7. Grounding Switch
Introduction
Wiring

Note: Each module needs independently wiring.
Basic Network Settings
Connect the cable and power on the device as instructed in the installation manual. Then, revise the terminal network parameters according to the live environment. There are two methods:
· Terminal Device Scanning Tool 1Under the menu of [optical disc:tool software] find “DevConfigTool” and run it, after starting, input the default password “123456”.
5 www.nordencommunication.com

2Please select the Mandatory configfrom the right menu, then filling each correct parameters in the [terminal parameter]. It will be finished IP parameter configuration once pressed “sending parameter”.
Remark: · When using a Windows 7 system, run the software in administrator mode
and disable all firewalls and related security software. · The terminal scanning tool can configure network parameters for only one
terminal at a time. Ensure that the computer is connected to only one target terminal during the configuration process. · Webpage Way Access the web interface of the 4-Channel 2-Way Audio Adaptor, adjust the network parameters based on the site environment, and click “Save” to apply the changes. For detailed steps, refer to the network parameter settings in the user-defined terminal parameters section.
www.nordencommunication.com 6

User-defined Terminal Parameters
Login Web Interface
1Please input the 4 Channel 2-way Audio Adaptor IP address to the address column of the browser (the factory default IP address is 192.168.1.101, it will automatically play the IP address when the press the terminal key without the cable inserted), then enter.
2Enter the username and password in the web interface (the default username and password are admin).
3Click OK to enter 4 Channel 2-way Audio Adaptor web interface.
7 www.nordencommunication.com

Network Parameters

The parameters specification as following:

Device No.

The only identify device No., it can`t repeat with another host. The defaults are 1.
Note: The factory default NO. of the 4-way module is 1, please set 4 – channel module to different numbers.

IP address

IP address of 4 Channel 2-way Audio Adaptor, the default is 192.168.1.101.
Note: the IP address of the 4-way module is 192.168.1.101, please set different IP address for 4 – channel module.

Device port

The device port number defaults to be 2046, please don’t modify without special situation

Subnet mask Please set the subnet mask. (the defaults is 255.255.255.0)

Default gateway

Network gateway of 4 Channel 2-way Audio Adaptor. (The default is 192.168.1.1

www.nordencommunication.com 8

Preferred DNS Preferred domain name resolver IP of 4 Channel 2-way Audio

server

Adaptor network

Alternate DNS Network alternate domain name resolver IP of 4 Channel 2-

server

way Audio Adaptor

System server

The IP address to log in the server, the default is 192.168.1.13.
The port default to be 2048, please don’t modify without special situation.

Alternate server

When the preferred server cannot log in, you can choose the alternate server, the defaulted IP is 192.168.1.14.

Handshake interval

Set the handshake interval time between the server and 4 Channel 2-way Audio Adaptor interval.

Audio and Alert Parameters

The parameters specification as following:

Code mode The code mode of broadcasting, default is PCM.

Line input volume

The volume of the audio line input0~15).

Broadcast

The sampling frequency of 4 Channel 2-way Audio Adaptor when

sampling rate broadcasting, the default is 22050Hz.

9 www.nordencommunication.com

Broadcast output volume

The volume of the 4 Channel 2-way Audio Adaptor when broadcasting.

The status of alarm input interface when the alarm input is not triggered. This status decides the alarm method.

Alarm input status

When the status is normally open, the alarm input interface be closed to trigger alarm.

When the status is normally close, the alarm input interface be open to trigger the alarm.

Alarm input linkage alarm output

When the alarm input is triggered, configure whether linkage alarm output.

The time for alarm output linkage recovery

The durable time after the alarm output is triggered by linkage.
Note: the effective durable time is 1-29 seconds. When the setting is 0, the alarm output will continually link.

Web Management
On the Web management parameters, the account and password to log in the browser can be changed.

Reboot Device
Click “Reboot” to manually reboot the devices.
www.nordencommunication.com 10

Reset to Defaults
Resort to Default: all the parameters reset to defaults.
Firmware Upgrade
Click “Enter Firmware Upgrade Mode” to access the upgrade interface. Then click “Scan” to select the correct firmware file and click “Firmware Upgrade” to begin the process. Once the upgrade is complete, the device will automatically reboot.
11 www.nordencommunication.com

System Logs
On the web page, the log of the 4-Channel 2-Way Audio Adaptor can be viewed. To clear the log, click “Clear All the Log.”
www.nordencommunication.com 12

Trouble Shooting
1. Why does the “terminal network services (UDP) start fail” warning display while the server software is starting up?
· If this warning message appears, it usually indicates that the local network connection has been lost. Please check and reconnect the network cable properly, exit the software, and then restart it.
2. Why the terminal is still “offline”? · Check Software Server and Main Controller: Ensure both are running properly. Before launching the server software, disable all firewalls, including the system firewall and any third-party antivirus firewalls. · Verify Network Connection: After powering on the terminal, the network port’s green light should remain steady, and the orange light should flash rapidly. If the green light is off, it indicates a hardware connection issue– check the network cable and switch for damage, disconnection, or malfunction. · Check Terminal IP Settings: Confirm that the terminal ID, server IP, local IP, and gateway IP are correctly configured according to the network environment. 3.