NORA NMTD Series Class II Dimmable Hardwire LED Driver Instruction Manual

NMTD Series Class II Dimmable Hardwire LED Driver

Specifications:

  • Item# NMTD-60/12D
  • Description: 12V 60W Class II Hardwired Dimmable Driver
  • Rating: 12V / 60W

Product Information:

The NMTD series Class II Dimmable Hardwire LED Driver is
designed for indoor use only. It must be installed in a
well-ventilated area free from explosive gases and vapors to ensure
proper operation, which requires the free flow of air. This
transformer is hard-wired, and installation should be performed by
a qualified electrician.

Installation Instructions:

  1. Before Installation: Always turn off the main
    power before installation.
  2. Installation Steps:
    1. Ensure the area is well-ventilated and free from explosive
      gases.
    2. Identify the appropriate transformer based on your voltage and
      wattage requirements.
    3. Connect the transformer following the specified tap connections
      (120V or 277V).
    4. Make sure to connect the white and black feeds correctly.
    5. For each specific model (NMTD-60/12D, NMTD-60/24D, NMTD-40/12D,
      NMTD-96/24D), follow the detailed wiring instructions provided in
      the manual.
  3. Post-Installation: After loading back to
    normal, press the restore button if the red light is on, indicating
    overload.

FAQ:

Q: Can I install the NMTD series LED driver myself?

A: No, installation should be carried out by a qualified local
electrician to ensure safety and proper functioning.

Q: What should I do if the red light is on?

A: If the red light is on, it indicates overload. Press the
restore button after loading returns to normal.

Q: What is included in the box?

A: The box includes one 40W/60W/96W Transformer, one 10′ Power
Line Connector, Strain Relief, 1/2 Caps, Reset Button, Transformer
Cover, Screw Driver Insert Point, and Strain Relief Dia. 1/2
Holes.

“`

Installation Instructions

***URGENT: READ PRIOR TO ATTEMPTING INSTALLATION***

TRANSFORMER & DRIVERS – CLASS II DIMMABLE HARDWIRE LED DRIVER

ALWAYS TURN OFF MAIN POWER BEFORE INSTALLATION

Item# NMTD-60/12D NMTD-60/24D NMTD-40/12D NMTD-96/24D

Description 12V 60W Class II Hardwired Dimmable Driver 24V 60W Class II Hardwired Dimmable Driver 12V 40W Class II Hardwired Dimmable Driver 24V 96W Class II Hardwired Dimmable Driver

Rating 12V / 60W 24V / 60W 12V / 40W 24V / 96W

INSTALLATION SHOULD BE CARRIED OUT BY YOUR LOCAL ELECTRICIAN.

PLEASE READ: IMPORTANT INFORMATION BEFORE INSTALLATION NMTD series is for indoor use only. Must be installed in a well-ventilated area free from explosive gases and vapors. Proper operation requires the free flow of air. As this transformer is hard-wired, it should only be installed by a qualified electrician.
Installation: · Shut off power at the main breaker before attempting installation · This power unit may be installed with a compaitble 120V magnetic low voltage dimmer switch · Compatible 3-way 120V MLV dimmers · All direct wire connections to the Dimmable Driver must be secured inside the built-in junction box · A disconnect device shall be incorporated in the field wiring. · Risk of electric shock. Do not use any connection pins to touch any electrical conductors. · This equipment is intended to be installed only by qualified personnel. The installation must be made in accordance with the current edition to the National Electrical Code and all applicable state and local building codes. The final installation must be approved by the appropriate qualified electrical/building inspector. Improper installation may result in a fire or electrical hazard. Be sure the electrical power to the circuit has been disconnected before installing this electrical system.

Mounting · Locations for mountign must be able to support the weight of the Power units. · It is recommended to mount the Power units vertically with the wiring compartment pointed downward. · N.E.C. requires all Power units to be grounded to the GREEN groundign wire, use 18AWG

Knockouts · Remove wiring knockouts as needed and install 1/2″ Strain relief to reduce strain on wires. · One knockout is reserved for input voltage while the second knockout is reserved for output voltage. Connection · Refer to the wiring diagram provided for accurate wire connections. · The Red (+) wire is the Positive lead wire. The Black (-) wire is the negative lead wire.

NMTD-60/12D 120V TAP CONNECTION

WHITE FEED
BLACK FEED

COM PRI 120 VAC PRI 227 VAC PRI

POWER UNITS

RED
OUTPUT: DC 12V 5.0A Max. 60VA
BLACK

WHITE FEED
BLACK FEED

277V TAP CONNECTION

COM PRI (WHT)
120 VAC PRI (BLK)
227 VAC PRI (ORG)

POWER UNITS

RED
OUTPUT: DC 12V 5.0A Max. 60VA
BLACK

® 6505 Gayhart St., Commerce, CA 90040 | Phone: 800.686.6672 | FAX: 800.500.9955 www.noralighting.com | e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2016

Installation Instructions

***URGENT: READ PRIOR TO ATTEMPTING INSTALLATION***

TRANSFORMER & DRIVERS – CLASS II DIMMABLE HARDWIRE LED DRIVER

ALWAYS TURN OFF MAIN POWER BEFORE INSTALLATION

NMTD-40/12D

120V TAP CONNECTION

277V TAP CONNECTION

WHITE FEED
BLACK FEED

COM PRI 120 VAC PRI 227 VAC PRI

POWER UNITS

RED
OUTPUT: DC 12V 3.3A Max. 40VA
BLACK

WHITE FEED
BLACK FEED

COM PRI (WHT)
120 VAC PRI (BLK)
227 VAC PRI (ORG)

POWER UNITS

RED
OUTPUT: DC 12V 3.3A Max. 40VA
BLACK

NMTD-60/24D 120V TAP CONNECTION

WHITE FEED
BLACK FEED

COM PRI 120 VAC PRI 227 VAC PRI

POWER UNITS

RED
OUTPUT: DC 24V 2.5A Max. 60VA
BLACK

WHITE FEED
BLACK FEED

277V TAP CONNECTION

COM PRI (WHT)
120 VAC PRI (BLK)
227 VAC PRI (ORG)

POWER UNITS

RED
OUTPUT: DC 24V 2.5A Max. 60VA
BLACK

NMTD-96/24D 120V TAP CONNECTION

277V TAP CONNECTION

WHITE FEED
BLACK FEED

COM PRI 120 VAC PRI 227 VAC PRI

POWER UNITS

RED
OUTPUT: DC 24V 4.OA Max. 96VA
BLACK

WHITE FEED
BLACK FEED

COM PRI (WHT)
120 VAC PRI (BLK)
227 VAC PRI (ORG)

POWER UNITS

RED
OUTPUT: DC 24V 4.OA Max. 96VA
BLACK

Characteristics · Constant voltage · Overload protection · Thermal protection
Red light on when overloaded Attention: Press restore button after loading back to normal
® 6505 Gayhart St., Commerce, CA 90040 | Phone: 800.686.6672 | FAX: 800.500.9955 www.noralighting.com | e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2016

Installation Instructions

***URGENT: READ PRIOR TO ATTEMPTING INSTALLATION***

TRANSFORMER & DRIVERS – CLASS II DIMMABLE HARDWIRE LED DRIVER

ALWAYS TURN OFF MAIN POWER BEFORE INSTALLATION

Item# NMTD-60/12D NMTD-60/24D NMTD-40/12D NMTD-96/24D

Description 12V 60W Class II Hardwired Dimmable Driver 24V 60W Class II Hardwired Dimmable Driver 12V 40W Class II Hardwired Dimmable Driver 24V 96W Class II Hardwired Dimmable Driver

Rating 12V / 60W 24V / 60W 12V / 40W 24V / 96W

INSTALLATION SHOULD BE CARRIED OUT BY YOUR LOCAL ELECTRICIAN.

INCLUDED IN BOX:
QTY. 1 1 1 2

DESCRIPTION 40W/60W/96W Transformer 10′ Power Line Connector Strain Relief 1/2″ Caps

Installation Instruction · Insert flat head screwdriver. Lift up transformer cover towards you (Dia.1) · Determine which side you are going to feed the transformer through 1/2″ holes (Dia.1) · Feed and wire 10′ power line connector through 1/2″ hole (Dia.2) · Apply strain relief to cable and insert into 1/2″ hole (Dia.3) · Refer to the wiring diagram provided on page 1 for accurate wire connections. · Place cap over unused 1/2″ hole · Replace transformer cover

Reset Button

Dia. 1

Transformer Cover

Dia. 2

Screw Driver Insert Point
1/2″ HOLES

Dia. 3 STRAIN RELIEF

® 6505 Gayhart St., Commerce, CA 90040 | Phone: 800.686.6672 | FAX: 800.500.9955 www.noralighting.com | e-mail: nora@noralighting.com
Specifications subject to change without notice. © 2016