  • Product Name: rLSXR Sensor
  • Type: Fixture Mount Motion Sensor
  • Electrical Specifications:
    • rLSXR: 120-277VAC, 50/60 Hz, 2.5W
    • rLSXR HVOLT: 347-480VAC, 50/60 Hz, 2.5W
  • Maximum Load: 450 W @ 120-277V, 800 VA @
    347-480V
  • Dimming Load Sinks

Product Usage Instructions:

Installation:

  1. Turn off the power supply to the installation area.
  2. Mount the rLSXR Sensor securely on the fixture according to the
    provided instructions.
  3. Connect the electrical wires following the wiring diagram
    provided in the manual.
  4. Restore power and test the sensor by moving within its
    detection range.

Operation:

Once installed, the rLSXR Sensor will detect motion within its
range and control the connected load accordingly. The sensor is
designed to provide energy-efficient lighting control.

Maintenance:

Regularly clean the sensor lens to ensure optimal detection
performance. Check for any loose connections or damage
periodically.

FAQ (Frequently Asked Questions):

Q: How can I adjust the sensitivity of the motion sensor?

A: The sensitivity of the rLSXR Sensor can usually be adjusted
using the controls provided on the sensor itself. Refer to the user
manual for specific instructions on sensitivity adjustment.

Q: Can the rLSXR Sensor work with LED lights?

A: Yes, the rLSXR Sensor is compatible with LED lights. Ensure
that the total load of the LED lights does not exceed the maximum
load specified for the sensor.

rLSXR Sensor
Fixture Mount Motion Sensor
360° COVERAGE · LINE VOLTAGE · INTERCHANGEABLE LENSES

SPECIFICATIONS (rLSXR)

Electrical Specifications Mechanical

Input Ratings rLSXR 120-277VAC, 50/60 Hz 2.5W rLSXR HVOLT 347-480VAC, 50/60 Hz 2.5W
Maximum Load 450 W @ 120-277 800 VA@ 347-480
Dimming Load Sinks <10mA (0-10 VDC LED Drivers/Ballasts)
Minimum Load None
Class Rating 0-10V Dimming can be wired Class 1 or 2 Mounting 1/2″ Knockout (7/8″ hole)
Mounting Height rLSXR 10: 7 to 15 ft (2.13 to 4.57 m) rLSXR 6: 15-45 ft (4.57-13.72m) rLSXR 9: 8-15 ft (2.44-4.57m) rLSXR 50: 40 ft (12.19m)
Connection Type Line and Low Voltage Leads

Environmental

Warrantied Operating Temperature -40º to 149º F (-40º to 65º C) Standards/ Ratings RoHS, UL 916, UL 924 (optional), FCC / IC / IFETEL

depending on selected lens type.

IMPORTANT SAFEGUARDS
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING:

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

· DO NOT USE OUTDOORS. · DO NOT MOUNT NEAR GAS OR ELECTRIC HEATERS. · EQUIPMENT SHOULD BE MOUNTED IN LOCATIONS AND AT HEIGHTS WHERE
IT WILL NOT READILY BE SUBJECTED TO TAMPERING BY UNAUTHORIZED PERSONNEL. · THE USE OF ACCESSORY EQUIPMENT NOT RECOMMENDED BY THE MANUFACTURER MAY CAUSE AN UNSAFE CONDITION.

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

1.

This device may not cause interference.

2.

This device must accept any interference, including interference that may cause undesired operation of the device.”

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée

aux deux conditions suivantes :

1.

L’appareil ne doit pas produire de brouillage;

2.

L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Reorient or relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

C

US LISTED

WARRANTY
5-year limited warranty.
Full warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

TITLE 20/24

· To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels. · Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. · Installation and service should be performed by a qualified licensed electrician.

· Maintenance should be performed by qualified person(s) familiar with the products’ construction & operation & any hazards involved. Regular maintenance programs recommended.

· To be installed to a circuit with overvoltage control to Overvoltage category Cat.III or less, minimum suppression rating 6.0 kV for a 600 V ac rms system voltage

· DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.

CAUTION: RISK OF PRODUCT DAMAGE
Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding equipment should be worn during all installation or servicing of the unit.
Do not tamper with contacts. Do not modify the product. Do not change or alter internal wiring or installation circuitry. Do not use product for anything other than its intended use.

WARNING – RISK OF ELECTRIC SHOCK
Verify that supply voltage is correct by comparing it with the
product information. Make all electrical and grounded connections in accordance with
the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped with UL approved recognized wire connectors. All unused connector openings must be capped.

WARNING – RISK OF BURN or FIRE
Do not exceed maximum wattage, ratings, or published operation conditions of product.
Do not overload. Follow all manufacturer’s warnings, recommendations
and restrictions to ensure proper operation of product.
CAUTION – RISK OF INJURY
Wear gloves and safety glasses at all times when installing, servicing or performing maintenance.

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com © 2024 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/2024

1 of 3

IS-RLSXR-001 Contains FCC ID: 2ADCB-RMODIT or 2ADCB-RMODIT3 Contains IC: 6715C-RMODIT or 6715C-RMODIT3 Contains IFETEL: RCPACRM18-1879 or RCPNLNL20-2057 Acuity Brands Lighting Inc. RMODIT

rLSXR Sensor
Fixture Mount Motion Sensor
360° COVERAGE · LINE VOLTAGE · INTERCHANGEABLE LENSES
BASE MODELS
· rLSXR 6: On/Off/Dim, Photocell, Passive Infrared (PIR) – High Mount 360° Coverage · rLSXR 10: On/Off/Dim, Photocell, Passive Infrared (PIR) – Low Mount 360° Coverage · rLSXR 9: On/Off/Dim, Photocell, Passive Infrared (PIR) – Small Motion 360° Coverage · rLSXR 50: On/Off/Dim, Photocell, Passive Infrared (PIR) – High Mount Aisleway Coverage · rLSXR 6 HVOLT: On/Off/Dim, Photocell, Passive Infrared (PIR), 347-480 VAC – High Mount 360° Coverage · rLSXR 10 HVOLT: On/Off/Dim, Photocell, Passive Infrared (PIR), 347-480 VAC – Low Mount 360° Coverage · rLSXR 9 HVOLT: On/Off/Dim, Photocell, Passive Infrared (PIR), 347-480 VAC – Small Motion 360° Coverage · rLSXR50 HVOLT: On/Off/Dim, Photocell, Passive Infrared (PIR), 347-480 VAC – High Mount Aisleway Coverage
INSTALLATION INSTRUCTIONS
· Field or factory installable for indoor applications · Sensor has a 1/2″ chase nipple that enables mounting through a knockout/hole in
a junction box, fixture, or pole. · To mount, push the unit’s threaded chase nipple through a 1/2″knockout (7/8″
hole) in a fixture. · When mounting to a pole, a 7/8″ unthreaded hole should be located 12″ below
luminaire and should be accessible via an adjacent or opposite side hand hole. · A snap lock mechanism on the chase nipple will secure the sensor.

depending on selected lens type.

HIGH MOUNT 360º MASKING KIT

Center-of-Aisle

End-of-Aisle

HIGH MOUNT AISLEWAY MASKING KIT

End-of-Aisle
· Masking labels are included with the high bay 360º lens to mask off a portion of its coverage pattern for end-of-aisle, or to trim the side viewing to create a rectangular pattern for center-of-aisle.
· Masking labels are included with the high bay aisle way lens to mask off a portion of its coverage pattern for end-of-aisle applications.

· To interchange lenses, pry out installed lens using a small flat screw driver inserted into one of the slots shown below
· Apply light pressure on lens frame sides to snap in new lens. · Install lens with the most optimum coverage pattern for a particular space and
application

OUT OF BOX OPERATION
· Occupancy Control: Enabled · Occupied Dim Level: 100% · Unoccupied Time Until Dim: 7.5 Minutes · Unoccupied Dim Level: 10% · Dim to Off Time Delay: 2.5 Minutes · Daylighting Control: Enabled · Daylighting Set Point: 50 fc · Daylighting Transition On Time: 45 Seconds · Daylighting Transition Off Time: 5 Minutes

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com © 2024 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/2024

2 of 3

IS-RLSXR-001 Contains FCC ID: 2ADCB-RMODIT or 2ADCB-RMODIT3 Contains IC: 6715C-RMODIT or 6715C-RMODIT3 Contains IFETEL: RCPACRM18-1879 or RCPNLNL20-2057 Acuity Brands Lighting Inc. RMODIT

rLSXR Sensor
Fixture Mount Motion Sensor
360° COVERAGE · LINE VOLTAGE · INTERCHANGEABLE LENSES

WIRING (DO NOT WIRE HOT)
WIRING TO SINGLE PHASE POWER (120/277/347 VAC) BLACK – 120/277/347 VAC Input BLUE – Switched Line Voltage Output to Luminaire WHITE – Neutral VIOLET – Low Voltage Dim Output (0-10 VDC) PINK – Low Voltage Common (0-10 VDC)

depending on selected lens type.

LUMINAIRE BALLAST or
LED DRIVER

PNK

GRY PNK*

*0-10V Dimming Common from luminaire may be pink or as otherwise indicated per section 410.69 of the 2020 NEC

WIRING TO 2-PHASE POWER* (208/240/480 VAC**) BLACK – 208/240/480 VAC Phase A Input BLUE – Switched Line Voltage Output to Luminaire WHITE – Phase B of 208/240/480 VAC Input VIOLET – Low Voltage Dim Output (0-10 VDC) PINK – Low Voltage Common (0-10 VDC)
*Safety Note: only one line phase is being switched **480 VAC for reference only – Factory install required

LUMINAIRE BALLAST or
LED DRIVER

PNK

GRY PNK*

*0-10V Dimming Common from luminaire may be pink or as otherwise indicated per section 410.69 of the 2020 NEC

WIRING TO EMERGENCY (-EM) UNITS BLACK – VAC Input Emergency Hot BLUE – Switched Line Voltage Output to Luminaire WHITE – Emergency Neutral VIOLET – Low Voltage Dim Output (0-10 VDC) PINK – Low Voltage Common (0-10 VDC)
UL924 Sequence of Operation (EM Option): For 90 minutes following any complete AC power interruption >30 ms: · Relay is closed and 0-10V dimming is at high end trim level · Device ignores wireless lighting control commands · If another nLight AIR device in the nLight AIR group (as defined by Clairity Pro) is on normal power,
and has its power restored prior to the 90-minute timeout, the “EM” device will exit this override state and return to normal operation. This is accomplished by having a normal power device send an “exit EM” message to the “EM” device · Devices that will send the “exit EM” command when normal power is present · Dimming Power Pack Devices (rPP20 D/DS) · ER Non-Dimming and Dimming Power Pack Devices (rPP20 D/DS ER) · Other nLight AIR Non-“EM” Devices (rLSXR, rSBOR, rSDGR, rIO, rES7, rMSOD) · Devices that will not send the “exit EM” command when normal power is present · Non-Dimming Power Pack Devices (rPP20) · Other nLight AIR “EM” Devices (rPP20 EM, rLSXR EM, rSBOR EM, rSDGR EM, rIO EM, rES7 EM,
rMSOD EM) · Ceiling Mount Sensors (rCMS) · Wall Switches (rPODB, rPODL) · nLight Air Adapter (nECYD) · Upon power up, “EM” devices will be at high trim setting for 90 minutes. During commissioning with Clairity Pro, the device will exit this override when a device is identified or added to the grid.

Emergency

EMERGENCY LUMINAIRE BALLAST
or LED DRIVER

PNK

GRY PNK*

*0-10V Dimming Common from luminaire may be pink or as otherwise indicated per section 410.69 of the 2020 NEC

For further troubleshooting guidance, please contact the Controls Technical Support Team

1(800)-535-2465

Contains FCC ID: 2ADCB-RMODIT or 2ADCB-RMODIT3 Contains IC: 6715C-RMODIT or 6715C-RMODIT3 Contains IFETEL: RCPACRM18-1879 or RCPNLNL20-2057
Acuity Brands Lighting Inc. RMODIT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Este equipo contiene el módulo con IFT #: RCPRIBM18-1491 La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.

Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitybrands.com © 2024 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/17/2024

3 of 3

IS-RLSXR-001 Contains FCC ID: 2ADCB-RMODIT or 2ADCB-RMODIT3 Contains IC: 6715C-RMODIT or 6715C-RMODIT3 Contains IFETEL: RCPACRM18-1879 or RCPNLNL20-2057 Acuity Brands Lighting Inc. RMODIT

Documents / Resources

nLiGHT rLSXR Sensor Fixture Mount Motion [pdf] User Guide
rLSXR, rLSXR HVOLT, rLSXR Sensor Fixture Mount Motion, rLSXR, Sensor Fixture Mount Motion, Fixture Mount Motion, Mount Motion

References

Leave a comment

Your email address will not be published. Required fields are marked *