POOLEX PC-SLP090
Gebruikershandleiding voor de POOLEX Silverline 90 zwembadwarmtepomp
Model: PC-SLP090
1. Inleiding
This user manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your POOLEX Silverline 90 Pool Heat Pump, model PC-SLP090. Please read this manual thoroughly before installation and use to ensure optimal performance and longevity of the unit.
2. Veiligheidsinformatie
Always adhere to local electrical codes and regulations. Installation must be performed by a qualified professional. Failure to follow these instructions may result in property damage, serious injury, or death.
- Zorg ervoor dat de stroomtoevoer is uitgeschakeld voordat u onderhouds- of servicewerkzaamheden uitvoert.
- Do not operate the heat pump if any part is damaged or missing.
- Houd kinderen en huisdieren uit de buurt van het apparaat als het in werking is.
- Een goede aarding is essentieel om elektrische schokken te voorkomen.
- Blokkeer de luchtinlaat- of -uitlaatopeningen niet.
3. Product voorbijview en componenten
The POOLEX Silverline 90 is a high-performance heat pump designed for heating swimming pools. It features a Mitsubishi compressor and a double-spiral titanium exchanger for efficient heat transfer.

Figuur 3.1: Voorzijde view of the POOLEX Silverline 90 heat pump, showing the main unit with the POOLEX Silverline logo and various indicators. This image illustrates the compact design and primary external features of the heat pump.

Figure 3.2: The POOLEX Silverline 90 heat pump, highlighting its compatibility with pools up to 45m³ and the integrated Touch & Go control system. This image emphasizes the user-friendly interface and capacity suitability.

Figure 3.3: Key features of the POOLEX Silverline 90 heat pump, including 6 capacities up to 85m³, titanium exchanger, power range of 5.5 to 18 kW, and anti-corrosion properties. This graphic summarizes the technical advantages of the unit.

Figure 3.4: Accessories included with the POOLEX Silverline 90 heat pump: maintenance cover, anti-vibration support kit, 10-meter extension cable, condensate drainage hose, and 50mm PVC connectors. This image details the complete package for installation and maintenance.

Figure 3.5: The POOLEX Silverline heat pump's energy efficiency, demonstrating up to 80% savings compared to traditional heating methods. This image highlights the economic benefit of using the heat pump.

Figure 3.6: The POOLEX Silverline 90 heat pump uses R410 ecological refrigerant, emphasizing its environmental friendliness. This image points out the type of refrigerant used and its eco-conscious design.

Figure 3.7: The POOLEX Silverline heat pump offers 6 capacities for pools up to 85m³, with a power range of 5.5 to 18 kW. This image illustrates the versatility and scalability of the heat pump series.
4. Installatie en installatie
4.1 Locatieselectie
Choose a well-ventilated outdoor location, away from direct sunlight and heat sources. Ensure sufficient clearance around the unit for proper airflow (minimum 50cm from walls or other obstructions). The ground must be level and capable of supporting the unit's weight (49 kg).
4.2 Loodgietersaansluiting
- Connect the heat pump to your pool's filtration system after the filter and before any chemical injection points.
- Use the provided PVC connectors (Ø 50mm) for water inlet and outlet.
- Zorg ervoor dat alle verbindingen waterdicht zijn om lekkages te voorkomen.
- Install a bypass valve system to allow for maintenance without draining the pool.
4.3 Elektrische aansluiting
Electrical installation must be performed by a certified electrician in accordance with local regulations.
- The unit requires an electrical power supply (Type: Electric).
- Ensure the circuit is protected by a suitable circuit breaker and residual current device (RCD).
- Zorg ervoor dat het apparaat goed geaard is.
- Connect the wired control extension (10m) if using the remote panel.
4.4 Eerste inbedrijfstelling
- Zorg ervoor dat de zwembadpomp draait en dat er water door de warmtepomp stroomt.
- Schakel de stroomtoevoer naar de warmtepomp in.
- Set the desired water temperature using the LCD control panel.
- Allow several hours or days for the pool water to reach the set temperature, depending on initial water temperature and ambient conditions.
5. Gebruiksaanwijzing
5.1 Control Panel (Touch & Go)
The heat pump is equipped with an LCD control panel featuring Touch & Go technology for easy operation. Refer to the specific instructions provided with the control panel for detailed navigation.
5.2 Temperatuurinstelling
Use the up/down arrows on the control panel to adjust the desired pool water temperature. The unit will automatically operate to maintain this temperature.
5.3-bedrijfsmodi
The heat pump primarily operates in heating mode. It will automatically turn on when the pool water temperature drops below the set point and turn off once the set point is reached.
5.4 Wi-Fi Module (Optional)
An optional Wi-Fi module is available for remote control and monitoring. Consult the Wi-Fi module's separate manual for installation and operation instructions.
6. Onderhoud
6.1 Regelmatige reiniging
- Keep the area around the heat pump clear of debris, leaves, and other obstructions.
- Clean the evaporator coil regularly with a soft brush or low-pressure water to ensure efficient airflow.
- Veeg de buitenkant schoon.asing met advertentieamp lap.
6.2 Winterklaar maken
Before winter or prolonged periods of non-use, it is essential to properly winterize the heat pump:
- Koppel de stroomtoevoer los.
- Drain all water from the heat pump's plumbing system to prevent freezing damage.
- Cover the unit with the provided maintenance cover or a suitable protective cover.
6.3 Condensaatafvoer
Ensure the condensate drainage hose is clear and properly routed to allow water to drain away from the unit's base.
7. Probleemoplossing
| Probleem | Mogelijke oorzaak | Oplossing |
|---|---|---|
| De warmtepomp start niet op. | No power; circuit breaker tripped; low water flow. | Check power supply; reset circuit breaker; ensure pool pump is running and filter is clean. |
| Onvoldoende verwarming | Ambient temperature too low; dirty evaporator coil; incorrect temperature setting; undersized unit for pool volume. | Heat pump efficiency decreases in cold weather; clean coil; verify temperature setting; ensure unit matches pool size (40-50m³ for this model). |
| Ongebruikelijk geluid | Losse onderdelen; verstopping van de ventilator; probleem met de compressor. | Check for loose parts; clear any obstructions from fan; if compressor noise persists, contact qualified technician. |
| Lekkend water | Loose plumbing connections; condensate drainage issue. | Tighten connections; ensure condensate hose is clear and properly routed. Note: Condensate drainage is normal operation. |
For issues not listed or if problems persist, contact a qualified service technician or POOLEX customer support.
8. Specificaties
| Functie | Detail |
|---|---|
| Modelnummer | PC-SLP090 |
| Merk | POOLEX (Manufacturer: Poolstar) |
| Vermogensafgifte | 9 kW |
| Aanbevolen zwembadvolume | 40 to 50 m³ (up to 110 m³ compatible) |
| Compressortype | High-performance Mitsubishi compressor |
| Wisselaartype | Double-spiral titanium exchanger (Twisted Tech) |
| COP (26/26 conditions) | > 6 |
| Afmetingen (L x B x H) | 92.7x34x63.6cm |
| Gewicht | 49 kg |
| Energietype | Elektrisch |
| Koelmiddel | R410 (Ecologisch) |
| Bedieningspaneel | LCD with Touch & Go technology |
| Verenigbaarheid | Compatible with all pool types, including salt treatment. |
9. Garantie en ondersteuning
For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official Poolstar webwebsite. Bewaar uw aankoopbewijs voor garantieclaims.
Included accessories: Anti-vibration support kit, PVC connectors (Ø 50mm 1½''), condensate drainage hose, multi-language user manual, wired control extension (10m).
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.