NetSuite FG-10N-2-TM 10 Gallon Fog Unit With Timer Owner’s Manual

FG-10N-2-TM 10 Gallon Fog Unit With Timer

Product Information

Specifications

  • Model: FG-10N-2-TM
  • Capacity: 10 Gallons
  • Timer Included
  • Maximum Incoming Air Pressure: 100 psi (6.9 bar)

Product Usage Instructions

Safety Precautions

It is crucial to follow all safety precautions to prevent
personal injury or damage:

  • Always wear appropriate Personal Protective Equipment (PPE) as
    indicated in the Safety Data Sheet (SDS).
  • Avoid direct contact with chemical solutions by wearing
    protective gear for eyes, skin, and lungs.
  • Depressurize and clean the unit after each use to prevent
    unexpected chemical solution release.
  • Do not operate the unit if damaged or leaking.
  • Avoid pointing the discharge wand at yourself, others, or
    unwanted objects.
  • Ensure incoming air pressure does not exceed 100 psi (6.9
    bar).
  • Avoid using hydrocarbons or flammable products with the
    unit.
  • Flush the unit thoroughly with fresh water when switching
    between alkaline and acid solutions.
  • Always inspect electrical cords for damage before use.

Proper Operation

  1. Ensure the unit is on a stable surface and properly connected
    to a power supply.
  2. Fill the tank with the desired chemical solution up to the
    designated capacity (10 gallons).
  3. Set the timer according to your application requirements.
  4. Wear appropriate PPE before operating the unit.
  5. Point the discharge wand towards the desired area to apply the
    chemical solution.
  6. After each use, depressurize the unit and clean it
    thoroughly.

Frequently Asked Questions (FAQ)

Q: Can I exceed the maximum incoming air pressure of 100
psi?

A: No, exceeding 100 psi may result in pressure buildup, posing
a risk of explosion or serious injury. Always adhere to the
specified pressure limit.

Q: How should I clean the unit after use?

A: To clean the unit after each use, depressurize it first, then
flush it thoroughly with fresh water to remove any chemical
residues.

Q: What should I do if I suspect electrical cord damage?

A: If you suspect electrical cord damage, do not touch it and
disconnect the unit from the power supply immediately. Inspect and
replace damaged cords before further use.

10 Gallon Fog Unit With Timer
Service Manual FG-10N-2-TM

READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)

Scan this code for service manual

Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death. Always depressurize and clean the unit after each use. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion, serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to an alkaline.
Touching damaged electrical cords may result in electrical shock, serious injury or death. Always inspect electrical cords and extension cords for damage before connecting the unit to power supply. DO NOT touch a damaged electrical cord, or extension cord, that is connected to power supply.

Model: FG-10N-2-TM

V20250310 · Page 2 of 12

NOTICE
Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit. Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an air lubricator before the unit. Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry and free of moisture. If needed, install an air dryer before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.

Service Guide
WARNING
Performing any maintenance with the unit pressurized, connected to air supply, and/or connected to electrical power may result in serious injury or death. Always ensure that the unit has been depressurized, disconnected from the air supply, and electrical power before conducting any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.

Maintaining Your Unit

To keep your unit operating properly, periodically perform the following maintenance procedures:

· Inspect the pump for wear and leaks.

· Inspect nozzles for debris. Clean as needed.

· Inspect all hoses for leaks or excessive wear.
· Ensure all hose clamps are in good condition and properly secured.
· Check suction line and strainer for debris. Clean as needed.

· Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear.
Note: If your air source has a high moisture content, install a water separator to the air fitting on the backplate. See Page 8 for more details. (Back plate assembly)

Servicing Your Unit

Most repairs on the unit can be performed with the following tools:

· Crescent wrench (2x)

· #2 Phillips head screwdriver

· /16 in. (11 mm) open-ended wrench

· #3 Phillips head screwdriver

· Flat head screwdriver

· Hose cutters

· Thread seal tape

· Knife

Model: FG-10N-2-TM

V20250310 · Page 3 of 12

Troubleshooting Your Unit

If your unit is not operating properly, try using these troubleshooting tips:

Issue Pump is cycling too fast

Solution · Ensure the suction line ball valve at the bottom of the tank is open.

Pump is cycling too slow

· Inspect the outlet side of pump for build up. Clean as needed.

Air passes through the pump without cycling

· The pump needs to be replaced.

Chemical found in the air bowl or · The pump diaphragm is torn, replace pump. coming out of the pump exhaust

The unit operates at a reduced pressure

· Check suction line and strainer for debris or damage. Clean or replace as needed. To prevent damage to the unit, the strainer must always be used.
· Check the air compressor supplying the unit. If the pressure is less than 40 psi (2.8 bar), turn off the unit until the compressor can catch up.
· If the air supply is 50 psi (3.4 bar) or above, check the air gauge, which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust pressure by turning the knob on the top of the air regulator.

Model: FG-10N-2-TM

V20250310 · Page 4 of 12

Tank Assembly

TNKA-10N-BK: 10 gallon natural tank assembly – black* lid – includes drain plug, wheels, suction valve, and backplate thumb nuts

LDA-7BK: Lid assembly – includes 7 in. black* lid, lid flange, hinge pin, and mounting screws

Item number

Description

1 LD-PIN

Hinge pin for 7 in. lid and flange

2 LD-7BK-LID Lid – 7 in. – polypropylene – black*

3 S812-FH

Screw – #8 x 1/2 in. – stainless steel flat head Phillips

4

LD-7BK-FLNG

Lid flange – 7 in. – polypropylene black*

* Additional colors available, see datasheet for options.

LDA-7BK 1 2 3
4

Item number 5 TNK-10N 6 DPA

Description
Tank – 10 gallon natural – portable
Drain plug assembly for portable units – includes gasket

5

Front view

Model: FG-10N-2-TM

6
V20250310 · Page 5 of 12

Tank Assembly

TNKA-10N-BK: 10 gallon natural tank assembly – black* lid – includes drain plug, wheels, suction valve, and backplate thumb nuts

BPTNA: Back plate thumb nut assembly – includes bolt, thumb nut, and tether

Item number 1 BST1420118-VS 2 TN1420

Description
Bolt – set – 1/4-20 x 1 1/8 in. – stainless steel – Vibra-Seal
Thumb nut – 1/4-20 x 1 1/4 in. – PP brass insert – assembled with tether

BPTNA

1

2

VLVA-BVPVC34: Suction valve assembly – includes 3/4 in. PVC valve, bushing, 3/4 in. hose barb elbow, and screw band clamp

Item number

Description

3 SSC38

Screw band clamp – stainless steel for 3/8 in. hose

4

BVPVC34MF

Ball valve – PVC – 3/4 NPT to 3/4 FNPT Buna seal

5 HHPB3414

Hex head poly bushing – 3/4 in. MPT x 1/4 in. FPT

6

HBSSEL1438

Hose barb – stainless steel – elbow 1/4 in. MPT x 3/8 in. barb

WHLA-AXL14: 10 in. wheel assembly – includes 14 in. stainless steel axle, axle plate, bolts, washers, and cotter pins

Item number 7 COT 8 PLSS-AXL 9 AXL14 10 B142012-VS 11 W10 12 FW58

Description
Cotter pin – stainless steel – 1/8 in. dia x 1 in. long
Axle plate – stainless steel – 2.5 in. x 1 in. – 2 holes
Axle – stainless – 0.625 dia x 14.5 in.
Bolt – 1/4-20 x 1/2 in. – stainless steel truss head Phillips – Vibra-Seal
Wheel – 10 in. – non-marking
Flat washer for 5/8 in. od pipe or axle stainless steel – 0.64 in. id x 1.2 in. od x 0.05 in. thk

4 VLVA-BVPVC34

7

8

WHLA-AXL14

Model: FG-10N-2-TM

Back view

3

5

6

9

10 11 12

V20250310 · Page 6 of 12

Back Plate Assembly

PA-PNZ-TM: Plate assembly for portable fog units with timer Santoprene pump
Additional plate assembly pump options: PA-PNZK-TM: Kalrez pump PA-PNZV-TM: Viton pump

Item number 1 A P56
B P56K C P56V 2 R14 3 QF5638 4 AG100 5 QFEL1438 6 H14BL-F 7 QFBH38 8 STR38-IL-80 9 H38BL-F 10 QFSEL38

Description
Pump with Santoprene seals includes hose barbs, air fitting, and exhaust barb
Pump with Kalrez seals – includes hose barbs, air fitting, and exhaust barb
Pump with Viton seals – includes hose barbs, air fitting, and exhaust barb
Regulator – air – 4x 1/4 in. FPT ports – no gauge
Quick fit pump fitting for 3/8 in. tube – EPDM o-ring – for G57/P56 – sold individually
Air gauge – in. NPT – 0-100 PSI markings – dry model
Fixed elbow 1/4 in. MPT x 3/8 in. tube – polypropylene
¼ in. id blue hose – hybrid TPE available per ft.
Bulkhead 3/8 in. tube polypropylene
In line strainer – 2x 3/8 hose barb EPDM gasket – #80 mesh SS screen – gray bowl
in. id blue hose – hybrid TPE available per ft.
Plug-in elbow 3/8 in. tube x 3/8 in. polypropylene

11 TB38N-PE

3/8 in. od natural tube polyethylene – available per ft.

Inside view

1

2

4

5

3

6

7

8

9

10 11

Model: FG-10N-2-TM

V20250310 · Page 7 of 12

Back Plate Assembly

Back view

PA-PNZ-TM: Plate assembly for portable fog units with timer Santoprene pump
Additional plate assembly pump options: PA-PNZK-TM: Kalrez pump PA-PNZV-TM: Viton pump

8

9

Item number

Description

1 SEL14M

Stainless elbow 1/4 in. MPT x 1/4 in. MPT 1

2 SSSFN12 Serrated flange nut – stainless – ½ in. 2

3 SSA14BKH

Bulkhead adapter – stainless steel 1/4 in. NPT x 1/4 in. NPSM

3

4 BVB14

Ball valve – brass – nickel plated –

4

air inlet valve – 1/4 in. FPT x 1/4 in. FPT

5

5 QF1438

Quick fit – 1/4 MPT x 3/8 od tubepolypropylene

6

6 TB38N-PE

3/8 in. od natural tube – polyethylene available per ft.

7

7 QFBH38 Bulkhead 3/8 in. tube polypropylene

8

ACB-PLPF120VAC

Air control box – PLPF – 120VAC delay timer – push button – toggles circuit breaker

9 AP14

Air fitting – 1/4 in. MPT quick disconnect hose coupling plug – nickel-plated brass

10

Optional Components

WSA-20CFM: Water separator assembly – 20 CFM – ¼ in. FPT ports –

11

includes air plug and union fittings

Item number

Description

10 SN1414

Stainless hex nipple ¼ MPT x ¼ MPT

11 SSU14

Stainless steel union – ¼ in. FPT

12

WS-20CFM

Tsunami water separator/air dryer 20 CFM – 1/4 in. FPT ports

13 AP14

Air fitting – 1/4 in. MPT quick disconnect hose coupling plug – nickel-plated brass

12 13
WSA-20CFM* *Optional assembly sold separately

Model: FG-10N-2-TM

V20250310 · Page 8 of 12

Back Plate Sub-assemblies

RGA-R14-PNZ: Air regulator assembly for portable fog units – includes air gauge, pump barb, hose, bulkhead fittings, and air plug

Item number

Description

1 HBB14P

¼ in. hose barb – brass – for G57/P56 air fitting with o-ring

2 EC14

Ear clamp – Oetiker – stainless steel for 1/4 in. hose

3 H14BL-F

¼ in. id blue hose – hybrid TPE available per ft.

4

HBSSEL1414

Hose barb – stainless steel – elbow 1/4 in. MPT x 1/4 in. barb

5 R14

Regulator – air – 4x 1/4 in. FPT ports no gauge

3 SSA14BKH

Bulkhead adapter – stainless steel 1/4 in. NPT x 1/4 in. NPSM

7 SSSFN12 Serrated flange nut – stainless – ½ in.

8 QFEL1438 9 HHSB1418 10 AG100

Fixed elbow 1/4 in. MPT x 3/8 in. tube polypropylene
Hex head stainless bushing 1/4 MPT x 1/8 FPT
Air gauge – in. NPT – 0-100 PSI markings – dry model

5

4
1 2
8 3

Model: FG-10N-2-TM

RGA-R14-PNZ

6

7

9 10

V20250310 · Page 9 of 12

Back Plate Sub-assemblies

SCTNA-PNZ: Suction assembly for portable fog units – includes suction valve, hose, in-line strainer, and pump hose barb – for Santoprene pump
Additional suction assembly options: SCTNA-PNZK: Kalrez pump SCTNA-PNZV: Viton pump

Item number 1 A HB5638
B HB5638K C HB5638V 2 STR38-IL-80 3 SSC38 4 H38BL-F 5 HBSSEL1438 6 HHPB3414 7 BVPVC34MF

Description
Hose barb for P56 pump EPDM o-ring
Hose barb for P56K pump Kalrez o-ring
Hose barb for P56V pump Viton o-ring
In line strainer – 2x 3/8 hose barb EPDM gasket – #80 mesh SS screen – gray bowl
Screw band clamp – stainless steel – for 3/8 in. hose
in. id blue hose – hybrid TPE available per ft.
Hose barb – stainless steel elbow – 1/4 in. MPT x 3/8 in. barb
Hex head poly bushing ¾ MPT x ¼ FPT
Ball valve – PVC – 3/4 NPT to 3/4 FNPT Buna seal

1
2 3

Model: FG-10N-2-TM

4

7

6

5

SCTNA-PNZ

V20250310 · Page 10 of 12

Back Plate Sub-assemblies

ACB-PLPF-120VAC: Air control box assembly – 120VAC – includes delay timer, push button, toggles, circuit breaker, and air plug

Item number

Description

1 PBA-664

Poly box assembly – 6 x 6 x 4 PVC – junction box

2 QFBH38 3 QFSEL38 4 TB38N-PE

Bulkhead 3/8 in. tube polypropylene

1

Plug-in elbow 3/8 in. tube x

3/8 in. polypropylene

2

3/8 in. od natural tube –

polyethylene available per ft.

3

5 TSW-PLT

Toggle switch – ON/OFF plate –

nickel-plated steel – mounting

4

hole for 15/32 keyed bushing

6 TSW-BDY

Toggle switch – body – single pole single throw – nickel-plated brass – 1/4 in. spade terminals 1/2 in. mounting hole – 15/32-32 keyed threaded bushing

7 TSW-BT

Toggle switch – mounting boot black silicone rubber – 15/32-32 integrated nut

Timer – multi-function relay –

8

TMR-MF-120VAC

0.05 sec. to 10230 hr. adjustable digi-set – 120 VAC – 10 A max –

uses 11 pin socket

9 QF1438

Quick fit – 1/4 MPT x 3/8 od tubepolypropylene

8

Fluid control valve – DEMA –

9

1/4 in. FPT – 7 GPM – polypropylene

10 FCV14-120VAC body – Viton diaphragm – 120 VAC

solenoid – normally closed – 18 in.

18 AWG flying leads

11 BUT78GR

Push button – flush green cap normally open

12 FW14NPT

Flat washer for 1/4 in. NPT stainless – 0.57 in. id x 1.28 in. od x 0.08 in. thk

13 CB-5

Circuit breaker assembly – 5 amp includes clear boot

14 SSA14

Stainless adapter 1/4 MPT x 1/4 FPT

15 AP14

Air fitting – 1/4 in. MPT quick disconnect hose coupling plug nickel-plated brass

Model: FG-10N-2-TM

5 67

13 14 15

10

11 12

V20250310 · Page 11 of 12

Nozzle Assembly

NZA-PNZX2-WBRKT-WTB: Nozzle assembly – includes 2x pneumatic nozzles, tank mounting bracket with mounting hardware, and tubing
NZA-PNZX2-WBRKT: Nozzle bracket assembly – includes 2x pneumatic nozzle, and tank mounting bracket with mounting hardware

NZA-PNZX2-WBRKT 1

Item number

Description

2

Pneumatic mixing nozzle –

1 PNZ-N130

polypropylene body – Kynar

tip – 3.7 gal/hr

3

2 EL14M14F

1/4 FPT x 1/4 MPT – polypro elbow

4

3

BRKT-TNK-PNZX2

Bracket for tank mounting 2x PNZ nozzles – stainless steel

5

Flat washer for 1/4 in. NPT –

4 FW14NPT

stainless – 0.57 in. id x

1.28 in. od x 0.08 in. thk

6

5 QF1438

Quick fit – 1/4 MPT x 3/8 od tube polypropylene

6 QFSEL38

Plug-in elbow 3/8 in. tube x 3/8 in. polypropylene

7 S1034

Screw – #10 x 3/4 in. – stainless steel – round head Phillips

7 8

Item number

Description

8 QFT38

Union tee 3/8 in. tube polypropylene

9 TB38N-PE

3/8 in. od natural tube polyethylene – available per ft.

9

Model: FG-10N-2-TM