NEMA -logo

Specification of GPRS wireless
single light controller
Version: NEMA interface wireless single light controller specification_V1.2
Date:2021-1

Introduction

The NEMA interface wireless single light controller is designed for road and area lighting in smart cities. It has the functions of switching, dimming, and monitoring lamps; GPS positioning function; environmental illumination detection, whether the street lamp is tilted, etc.

1.1 Safety Instructions
The following safety principles are followed to ensure personal safety and to help protect the product and work environment from potential damage.

NEMA -icon When in an airport or other places, it is necessary to prevent the terminal from causing interference to the aircraft communication system. Ignoring this prompt may lead to flight safety issues and even violations of the law.
NEMA -icon1 When in a hospital or health care place, users need to pay attention to whether there are restrictions on the use of terminal equipment. RF interference can cause the medical device to malfunction, so it may be necessary to turn off the terminal device.
NEMA -icon2 The terminal device does not guarantee an effective connection under any circumstances, and it is necessary to ensure that the device is powered on and in an area with sufficient signal strength.
NEMA -icon3 Terminal device will receive and transmit RF signals when it is turned on. Radio frequency interference occurs when you are near a radio or other electronic device.
NEMA -icon4 Keep the device away from flammable gases. Do not put it near gas stations, oil depots, chemical plants, or explosive work sites. There are hidden dangers in operating electronic equipment in any potentially explosive atmosphere.

Features

2.1 Main Features

Features Description
 

Supply power

Wide voltage input design: can work at 100-264VAC Surge protection: 4KV, 4KA
 

Save power

Working power consumption: <2W Power off consumption: <0.4W (120V); <0.5W (230V)
Working temperature -40~70℃
 

GPRS module

Working in 850/900/1800/1900MHz quad-band ISM frequency band; Comply with IEEE802.15.4 standard;

AES128 encryption

 GPRS data characteristics In Single Tone mode: Data downlink transmission: 85.6kbps Data uplink transmission: 85.6kbps In Multi Tone mode: Data downlink transmission: 85.6kbps Data uplink transmission: 85.6bps Support IPv4, IPv6, UDP, CoAP, PPP, SMTP, DTLS, TCP, and other protocol stacks
Driving power Supports up to 1000W LED driver
Dimming interface Equipped with 1 channel 0~10V dimming interface (analog), one channel PWM
 

Self-information monitoring

Monitor the lamp input voltage, current, power, power factor, and Temperature. Statistical energy consumption and working hours
location GPS accuracy ±6M (without obstruction to the air)
Light control Meets ANSI C136.10 standard (only in offline mode, Optional)
 

Dimming

Strategic dimming Group dimming The lamps still work according to the set dimming schedule and illuminance even when communication fails
 

protection

 

Overvoltage, over current, short circuit protection

Warranty 5 years

 Specification

3.1 Absolute Maximum Range

PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Min input voltage  

100

 

/

 

/

 

VAC

Max input voltage  

/

 

/

 

264

 

VAC

Max output current Peak@100mS  

/

 

/

 

5

 

A

Max dimming current RMS  

/

 

/

 

10

 

mA

3.2 Electrical Specification
At 220VAC input, 20°C, 50% humidity, 100Kpa atmospheric pressure.

PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
AC input voltage  

100

 

/

 

264

 

VAC

AC input current  

220VAC

 

0.02

 

/

 

5

 

A

AC output current 220VAC,RMS  

0

 

/

 

5

 

A

Power Dissipation  

0.4

 

/

 

2

 

W

Dimming voltage  

0

 

/

 

10

 

V

Dimming current  

10Voutput

 

0

 

1

 

10

 

mA

Dimming accuracy  

-1

 

/

 

+1

 

%

 

Metering voltage range

 

 

0

 

 

/

 

 

300

 

 

VAC

Metering current range  

0

 

/

 

20

 

A

Metering voltage accuracy  

 

-2

 

 

/

 

 

+2

 

 

%

Metering current accuracy  

 

-2

 

 

/

 

 

+2

 

 

%

RF transmission

distance

 

3dBi antenna

 

 

500

 

 

/

 

 

/

 

 

m

RF transmission rate Good signal  

/

 

250

 

/

 

Kbps

RF band  

850

 

/

 

1900

 

MHz

RF receiver sensitivity  

 

-98.8

 

 

/

 

 

/

 

 

dBm

RF transmitter power  

/

 

26±2

 

dBm

Spectral range of  

Photocell

 

 

/

 

 

/

 

 

/

 

 

nm

sensitivity
GPS Sensitivity Tracking  

/

 

-160

 

/

 

dBm

3.3 Operating Condition

PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Operating temperature  

-40

 

/

 

70

 

 

Storage temperature

Indoor dry,  

 

-40

 

 

/

 

 

80

 

 

well-ventilated

place

Relative humidity No frost  

10

 

/

 

95

 

%

Vibration  

/

 

/

 

10

 

G

Warranty  

5

 

Years

Ingress protection Not Installed  

/

 

IP53

 

/

Packaging Impact Drop  

/

 

1

 

/

 

m

Flammability  

UL94-V0

3.4 Safety

TYPE Test level
Isolation Voltage AC to Dimming  

3kVac,10mA,1min

Certification UL773/EN61010-1/EN61347
3.5 Electromagnetic Compatibility
TYPE/ Standard/ Test level/
Electrostatic discharge immunity  

 

IEC61000-4-2

 

 

Level 4

RFEMS  

IEC61000-4-3

 

Level 2

Electrical fast transient burst  

 

IEC61000-4-4

 

 

Level 4

immunity
Surge Immunity  

IEC61000-4-5

Level X
4KV,4KA
Conducted disturbances induced by  

 

IEC61000-4-6

 

 

Level 2

RF field immunity
Power frequency magnetic field  

 

IEC61000-4-8

 

 

Level 3

immunity
Electromagnetic

disturbance

 

 

FCC PART15 Class B / EN55015

characteristics
Electromagnetic compatibility and  

 

EN300328/EN301489-1/EN301489-17/EN300440-2/

Radio spectrum Matters (ERM)
EN62479/EN61326-2-1

Structural Data

4.1 Size

NEMA GPRS Wireless Single Light Controller-

4.2 Interface

NEMA GPRS Wireless Single Light Controller-fig

  • PIN Li: Live line input
  • PIN Lo: Live line output
  • PIN N: Neutral line input
  • PIN 1: CH1 Dim+
  • PIN 2: CH1 Dim-
  • PIN 3: CH2 Dim+
  •  PIN 4: CH2 Dim-
  • The Rubber Ring makes installation ingress protection can reach IP65;
  • Complies with ANSI C136.41-2013.
    ANSI C136.41-2013

Part Description

NEMA GPRS Wireless Single Light Controller-fig1

5.1 GPRS Wireless Module
GPRS module can be used to communicate with the base stations and help to transfer a variety of instructions, such as: switching ON/OFF, dimming commands, uploading power consumption data, uploading illuminance information, etc.
5.2 Control Module
After booting, the module automatically obtains the command sent by the system to start the dimming strategy. If not set, the module will dim according to the factory default strategy.
5.3 Light sensor (optional)
The light sensor uses a digital light sensor. Its sensing range is adapted to the recognition range of the human eye. After the module joins the NB network, it will upload the illuminance data to the gateway. When the module works offline, it will turn on the lights at 16±6 lux and turn off the lights at 50±6 lux (default setting).
5.4 Dimming
The product has 1 channel 0-10V analog dimming interface and one channel PWM interface. To better accommodate the needs of multiple LED drivers, the default dimming curve is shown in Figure 5.
NEMA GPRS Wireless Single Light Controller-fig2

Application

6.1 Sockets and modules
The module needs to be used with the twist lock light control socket. (According to ANSI C136.41 requirements), the socket is shown in Figure 6.

NEMA GPRS Wireless Single Light Controller-fig3

6.2 Typical Application

NEMA GPRS Wireless Single Light Controller-fig4

FCC Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following age 25 measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TVtechnician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
SAR Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment’s normal use should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Documents / Resources

NEMA GPRS Wireless Single Light Controller [pdf] User Manual
WEMA10, 2AZNC-WEMA10, 2AZNCWEMA10, GPRS Wireless Single Light Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *