The NI-5753 is a digitizer adapter module manufactured by National Instruments. It is part of the NI 1483/57xx/65xx FlexRIO Adapter Modules series. The module is designed to capture waveforms and is compatible with various other adapter modules in the series.
The NI-5753 module has the following board assembly part number and revision:
- Part Number: 143234A-0x or later
- Revision Description: NI 5753, DIGITIZER ADAPTER MODULE
The module is equipped with volatile memory and non-volatile memory. The volatile memory requires power to maintain stored information, while the non-volatile memory retains its contents even when power is removed.
Product Usage Instructions
To use the NI-5753 digitizer adapter module, follow these steps:
- Ensure that your PC or chassis containing the module is completely powered off. A simple reboot is not sufficient for the process.
- Carefully install the NI-5753 digitizer adapter module into the appropriate slot in your system.
- Make sure that all necessary connections, such as data and power cables, are securely attached to the module.
- Power on your PC or chassis to provide power to the module.
- If required, configure the module using the appropriate software provided by National Instruments.
- You can now use the NI-5753 digitizer adapter module to capture waveforms according to your application requirements.
Note: For further information and support, please refer to the most recent version of the user manual available at ni.com/manuals or contact National Instruments support at 866-275-6964 or support@ni.com.
Manufacturer
National Instruments
Board Assembly Part Numbers (Refer to Procedure 1 for identification procedure):
Part Number and Revision | Description |
198812A-01L or later | NI 1483, CAMERA LINK ADAPTER MODULE |
151148A-0xL or later | NI 5731/5732/5733/5734, DIGITIZER ADAPTER MODULE |
153113A-0xL or later | NI 5741/5742, SIGNAL GENERATOR ADAPTER MODULE |
199543A-01L or later 158676A-01L or later | NI 5751/5751B, DC COUPLED DIGITIZER ADAPTER MODULE |
199468A-01L or later 158679A-01L or later | NI 5752/5752B, AC COUPLED DIGITIZER ADAPTER MODULE |
143234A-0x or later | NI 5753, DIGITIZER ADAPTER MODULE |
150937A-0x or later | NI 5761, DIGITIZER ADAPTER MODULE |
151727A-0xL or later | NI 5762, DIGITIZER ADAPTER MODULE |
195815A-0xL or later | NI 5771, DIGITIZER ADAPTER MODULE |
152125A-0xL or later | NI 5772, DIGITIZER ADAPTER MODULE |
196496A-01L or later | NI 5781, BASEBAND TRANSCEIVER ADAPTER MODULE |
153241A-0x or later | NI 5782, IF TRANSCEIVER ADAPTER MODULE |
158183A-0xL or later | NI 5783, BASEBAND TRANSCEIVER ADAPTER MODULE |
152888A-01L or later | NI 5791, RF TRANSCEIVER ADAPTER MODULE |
152889A-01L or later | NI 5792, RF RECEIVER ADAPTER MODULE |
152890A-01L or later | NI 5793, RF TRANSMITTER ADAPTER MODULE |
198713A-01L or later 156996A-01L or later | NI 6581/6581B, DIGITAL ADAPTER MODULE |
199490A-0xL or later | NI 6583, MIXED LOGIC DIGITAL ADAPTER MODULE |
199496A-0xL or later | NI 6584, RS-485/RS-422 DIGITAL ADAPTER MODULE |
190687A-01L or later 156999A-0xL or later | NI 6585/6585B, LVDS DIGITAL ADAPTER MODULE |
192169A-01L or later | NI 6587, LVDS DIGITAL ADAPTER MODULE |
157002A-01L or later | NI 6589, LVDS DIGITAL ADAPTER MODULE |
Volatile Memory
Battery | User1 | System | Sanitization | |||
Target Data | Type | Size | Backup | Accessible | Accessible | Procedure
None |
Non-Volatile Memory (incl. Media Storage) | |||||
Target Data Type |
Size |
Battery Backup | User Accessible | System Accessible | Sanitization Procedure |
Device configuration, Product EEPROM | 2 KB | No | Yes | Yes | Procedure 2 |
Identification and Configuration |
- Refer to Terms and Definitions section for clarification of User and System Accessible
Procedures
Procedure 1 –Board Assembly Part Number Identification:
To determine the Board Assembly Part Number and Revision, refer to the label applied to the surface of your product. The Assembly Part Number should be formatted as “P/N: #####a-##L
Procedure 2 – Device Configuration EEPROM:
The Device Configuration EEPROM and its entire address space are exposed through the FlexRIO Host Interface in LabVIEW. To clear the entire EEPROM, overwrite the entire address space with null values using either the FlexRIO_Host_EEPROMWriteByteArray VI or FlexRIO_Host_EEPROMWrite32 VI.
Terms and Definitions
Cycle Power:
- The process of completely removing power from the device and its components and allowing for adequate discharge. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.
Volatile Memory:
- Requires power to maintain the stored information. When power is removed from this memory, its contents are lost. This type of memory typically contains application-specific data such as capture waveforms.
Non-Volatile Memory:
- Power is not required to maintain the stored information. The device retains its contents when power is removed.
- This type of memory typically contains the information necessary to boot, configure, or calibrate the product or may include device power-up states.
User Accessible:
- The component is read and/or write addressable such that a user can store arbitrary information about the component from the host using a publicly distributed NI tool, such as a Driver API, the System Configuration API, or MAX.
System Accessible:
- The component is read and/or written addressable from the host without the need to physically alter the product.
Clearing:
- Per NIST Special Publication 800-88 Revision 1, “clearing” is a logical technique to sanitize data in all User Accessible storage locations for protection against simple non-invasive data recovery techniques using the same interface available to the user; typically applied through the standard read and write commands to the storage device.
Sanitization:
- Per NIST Special Publication 800-88 Revision 1, “sanitization” is a process to render access to “Target Data” on the media infeasible for a given level of effort. In this document, clearing is the degree of sanitization described.
- Notice: This document is subject to change without notice. For the most recent version, visit.ni.com/manuals.
- Contact: 866-275-6964 support@ni.com
Documents / Resources
![]() |
National Instruments NI 65xx FlexRIO Adapter Modules [pdf] Instruction Manual NI-5753, NI 5731-5732-5733-5734, NI 5741-5742, NI 5751-5751B, NI 5752-5752B, NI 5753, NI 5761, NI 5762, NI 5771, NI 5772, NI 5781, NI 5782, NI 5783, NI 5791, NI 5792, NI 5793, NI 6581-6581B, NI 6583, NI 6584, NI 6585-6585B, NI 6587, NI 6589, NI 65xx, NI 65xx FlexRIO Adapter Modules, FlexRIO Adapter Modules, Adapter Modules |