NAPCO-LOGO

NAPCO R-PH Proximity Card Reader

NAPCO-R-PH-Proximity-Card-Reader-PRODUCT

FAQs

Q: What should I do if the reader does not power on?

A: Check the power source connections and ensure proper voltage input.

Q: Can the reader be used outdoors?

A: Yes, the reader is suitable for both indoor and outdoor installations. Use stainless steel screws for outdoor mounting.

Q: How do I change the LED functionality?

A: LED functionality is controlled by the access control panel. Refer to the Reader Wiring section for details on changing LED modes.

PRODUCT INFORMATION

Carefully follow this Getting Started Guide for the model R-PH 125 kHz Proximity Reader to ensure all wiring connections are made accurately.

Reader Wiring

Wiegand
Conductor Function
Red DC (7.5-16 VDC)
Black Ground
Green Data 0
White Data 1
 

Brown

Green/Blue LED Control Input
 

Orange

Green LED Dual Line Control
Yellow Card Present
Blue Sounder
Drain Shield Ground

WIRING NOTES:

  • a Single Line LED: This is the standard operating mode (Orange conductor not used). The LED is Blue when the reader is idle and flashes when a card is presented. The LED turns Green when the Brown Conductor is pulled low by the access control panel.
  • b Dual Line LED: This mode uses both the Brown and Orange con-ductors. The Brown conductor controls the Blue LED and the Orange conductor controls the Green LED, as determined by the access control panel. Unused conductors should be trimmed, isolated, and taped back to prevent unintended current flows.

Features

  • Indoor / Outdoor use
  • Single / Dual Line LED Control.
  • Standard Wiegand D0-D1 Data Output
  • Field Firmware Upgradable using the PR-PROG Reader/Programmer
  • Auto Configuration of Single Line LED or Dual Line LED Control*
  • Low Current Consumption
  • Up to 500ft. Reader to Panel Wire Length

Normal Operation

  • Connected to an access control panel: Presenting a supported proximity credential will result in the reader beeping, the blue LED turning off and the green LED turning on. Indicates credential has been validated and the door is ready to open
  • If NOT connected to an access control panel: Presenting a supported proximity credential will result in the reader beeping and the blue light bar flashing. The green light bar will not turn on

Cable Requirements

Use minimum 24AWG multi-conductor stranded wire with an overall foil shield (e.g., Belden 9535 or similar 5-conductor 24AWG gauge wire) com-prising the physical layer of the Wiegand interface (power, ground, Data 0, Data 1, and/or beeper and LED). Alternatively, use Belden 9539 or a similar 9-conductor 24AWG wire.

Mounting

Suitable for indoor or outdoor installations. Use the supplied mounting screws or security screws appropriate for the installation and/or mounting surface. Supplied are two #6-32 screws for met-al / single gang box mounting (cover plate also supplied); also supplied are two #6 sheet metal screws and drywall anchors. Stainless steel screws are recommended for outdoor installations.

Data Output

  • Wiegand D0-D1 26-bit to 37-bit.

Signals

  • Note that the Brown, Orange, Yellow, and Blue signal lines are actively low.

Shield Connection

  • The shield and the reader ground wire should be tied together at the access panel and connected to the earth’s ground at one point. Follow all earth-grounding requirements as detailed by the access control panel manufacturer.

Power

  • Power the reader with an access control panel or an independent external power supply. When the reader is powered on, it beeps 3 times and the light bar will light green, then blue. Note: The access panel controls LED functionality, such as switching the light bar to green (see Reader Wiring).

By default, the unit powers up in Single Line LED mode; but when the orange conductor sees activity (pulled active low), the unit changes to Dual Line LED mode. Refer to Reader Wiring, above.

Voltage / Current

Rated 7.5VDC (48mA while active) to 16VDC(80mA while active) voltage measured at the reader The use of 22AWG (or heavier) wire for longer cable runs is recommended.

Connection

All wiring should be performed within all appropriate local electrical codes

Troubleshooting

If the reader does not function correctly when a proximity credential is presented, see the table below for possible causes.

Symptom Possible Cause
Short proximity card read range or blue light bar will not light The typical card read range is up to 4″.

Verify a minimum of 7.5V at the reader. If the voltage is too low, the cable may be too thin.

 

Short proximity card read range or no read range

Noise on the power supply (temporarily power unit with a 9V battery to determine if performance improved). Improper panel and shield grounding or the use of unshielded wire.
No response from the reader when the card is presented Verify the correct card type. The unit may be defective.

If performance is still not improved after taking corrective action, remove power by disconnecting the reader from the access control panel and powering the reader with a separate power supply or a 9VDC battery, then re-test proximity credential functionality. If performance is not improved, the unit may be defective; contact NAPCO Technical Support at 1-800-645-9440.

Specifications

Operating Temperature

  • -40°F to +150.8°F (-40°C to +66°C)
  • Operating Humidity
  • 0% to 90% Relative Humidity
  • IP Rating
  • IP67-rated for outdoor use
  • Typical Card Read Range
  • Up to 4″ (10cm)

Access Control Levels

  • Destructive Attack: Level I
  • Line Security: Level I
  • Endurance: Level IV
  • Standby Power: Level I

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interfer-ence that may cause undesired operation

All trademarks, service marks, and product or service names described in this manual are for identification purposes only and may be trademarks or registered trademarks of their respective owners. The absence of a name or logo in this document does not constitute a waiver of any and all intellectual property rights that NAPCO Security Technologies, Inc. has established in any of its product, feature, or service names or logos. All information in this manual is for informational purposes only, and is subject to change without notice.

CONTACT INFORMATION

  • 333 Bayview Avenue, Amityville, New York 11701
  • For Sales and Repairs, 800-645-9445
  • For Technical Services, 800-645-9440 or visit us at
  • Tech.NapcoSecurity.com
  • (Note: Technical Service is for security professionals only)
  • Publicly traded on NASDAQ Symbol: NSSC

Documents / Resources

NAPCO R-PH Proximity Card Reader [pdf] User Guide
R-PH, R-PH Proximity Card Reader, Proximity Card Reader, Card Reader, Reader

References

Leave a comment

Your email address will not be published. Required fields are marked *