My Weigh | High Quality Digital Pocket Scales– SMOKEA®My Weigh 5500 Table Top Precision ScaleMy-Weigh-iBalance-5500-Table-Top-Precision-Scale-img

INTRODUCTION

With a 5500 gram capacity and a 0.1 gram resolution, the My Weigh iBalance 5500 Table Top Digital Jewelry Scale also measures weights in pounds (12.1000 pounds x 0.0005 pounds), troy ounces (176.860 ounces x 0.005 ounces), pennyweights (3537.0 dwt x 0.05 dwt), carats (27500.0 ct. x 0.5 ct.), grains, and other (84878 gn. x 1 gn.). This scale has a stainless steel platform, a backlit display, and a levelling system.

Thank you for purchasing the My Weigh” I8alance” s500 digital scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service. For more information please Visit www.myweigh.com never load the scale with more than the maximum capacity. Although the iBalance” SS00 is designed to be extremely durable with extra overload protection built into the case, overloading will permanently damage it! Avoid any exposure to extreme heat or cold, your scale works better when operated at normal room temperature. Keep your scale in a dean environment. Dust, dirt, moisture, vibration, air currents and/or a close proximity to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale. Handle with care. Gently apply all items to be weighed onto tray top. Avoid shaking, dropping or otherwise shocking the scale. Scales are delicate instruments and unlike cellular phones, scales have delicate sensors that determine how much an item weighs. If you drop or shock your scale, these sensors “feel” the shock and are sometimes destroyed. This happens with all digital scales. We design our scales to be as resistant to shock or drops as possible, however there is no way for us to protect 100% against load cell or sensor damage. Failure to follow these instructions will void your warranty. Always allow the scale to acclimate to normal room temperature for at least one hour before use. Give your scale sufficient warm-up time. Usually, 30-60 seconds before calibration to give the internal components a chance to stabilize.

SPECIFICATION

  • CAPACITY: 5500g x 0.19
  • UNITS: g, 02, b, ozt, dwt, ct, gn pCS
  • AUTO-OFF: 2 min.
  • SCALE DIMENSION: 200mm x 240mm x 80mm
  • TRAY DIMENSION: 140 x 165mm
  • OPERATING TEMPERATURE: Optimum 10-40°C (50-104’1)
  • POWER SOURCE: 6xAA batteries or AC power adaptor-DC 9V 100mA
  • TARE RANGE: Up to scale’s maximum capacity
  • ZERO RANGE: 59% of max. capacity

PRECAUTIONS BEFORE USING THE BALANCE

  1. Matter charged with static electricity can affect accuracy. Discharge all static electricity. For example, one method is to use Static-Guard spray, and spray it on both sides of the weighing platform.
  2. The balance must an exactly horizontal position in order to achieve accurate measurement results. In order to bring the balance into a horizontal position, the adjustable feet are turned either clockwise or counter-clockwise until the air bubble on the front panel s in the center of the marked circle.
  3. Please use an independent power outlet to avoid interference from other electrical appliances.
  4. Don’t put any object on the platform before powering on.
  5. When possible please allow the scale to warm up for several minutes before operation.
  6. Items should always be placed on the center of the platform when being weighed.
  7. For optimum accuracy, recalibrate before each use.

POWER SUPPLY

AC Adapter

The scale can be powered by an adaptor-output is DC 9V 100mA. Please only use the correct AC adaptor for this scale-an incorrect AC adaptor can cause damage to the scale and possible fire or injury. Use of an incorrect AC adaptor will also void your warranty.

BATTERIES

Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns from consumers and 60% of them are battery related problems. This sounds silly but it’s true! A scale will perform poorly when it has low batteries. Use good quality batteries & replace them often (Remove the batteries if you plan to store the scale for longer than 14 days). We include good quality batteries with all of our scales but they can run low in storage. If your scale simply won’t turn on while on battery power, it is often caused by loose battery connections. Battery prongs (terminals) are made of metal and they have to be in contact with the batteries. You can use a paperclip to slightly bend the battery prongs to have a better connection. Some poorly designed batteries have recessed or partially obstructed battery terminals. This may cause your prongs to be touching the plastic housing of the battery instead of the metal of the battery terminal

Battery installation

  1. a) Press and lift open the battery cover located at the bottom of the unit.
  2. b) Insert the batteries and make sure the polarity is correct (+) and (-).
  3. c) Close the battery cover until it dicks shut.

Note: IF the battery symbol appears in the display, it means low battery power. It is time to replace the battery. If the power is too low, it will show “Lo” when powered on and then it will turn off automatically.

OPERATION INSTRUCTIONS

Weighing Procedures

  1. Press [ON/0FF] to turn on the scale.
    When the power is tuned on, the scale will countdown for a few seconds and 0″ will appear on the display.
  1. Select the weighing unit with [UNITS] key.
  2. Press [UNITS] to select a weighing unit 9, 02, lb, ozt, dwt, ct, gn, pc.
    Once the unit has been selected, the selected unit will be displayed next to the weight value.
  3. Start weighing
    Verify the reading is “O”. Place objects on the weighing platform to weigh. When the reading becomes stable, the stable indicator is displayed.

TARE

Tare can be used for eliminating the weight value of an empty container. Place an empty container on the scale and press [Z]. Then place the items to be weighed in the container. NOTE: When all weight is removed from the weighing tray, the tared value of a container will be displayed as a negative number. Press (Z] again to return the scale to zero

CALIBRATION

How to calibrate **you must have an accurate 5000 g weight or combination of weights in order to calibrate*

Calibration may be required when the scale is first set up for use, or if the scale is moved to a different altitude or new location. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations can occur.

  1. From the offsetting press & hold the [Z]button, then press the [ON/OFF] button, release both keys. The display shows “CAL'” and an AD value.
  2. Press [(UNITS], and the display will show the correct calibration weight”S000.0
  3. Place the correct calibration weight on the platform and then press[UNITS]. The display will show ” ” and then an AD value. Turn off the scale and remove the weight(s).
  4. The calibration process is complete.

Counting Function

  1. Press [ON/OFF] to turn on the scale. Wait for “0” to appear on the display.
  2. Press [UNITS] several times until the scale is in PCS mode (the indicator should be on pcs).
  3. Select the sample size by pressing [PCS]. Either 10, 20, 50 or 100.
  4. Put the exact quantity of samples desired on the platform and press [UNITSI, the display will show “PASS
  5. Place the items that you want to be counted onto the tray and the total number of items will show on the display.
  6. Press the unit’s key to exit the counting function and return to normal weighing or you can press [ON/OFF] to turn the scale oft.

Auto-off

Auto shut off feature is provided to conserve battery power. The unit will automatically turn off after 2 minutes of inactivity.

To Enable or Disable the Auto-off

  1. The scale should be OFE. Press and hold [UNITS], then press and release [0N/OFF] the display will show A-ON =Auto-0ffenabled / A-OFF=Auto-0ff disabled.
  2. Press (Z) to toggle between the auto off settings.
  3. To confirm the setting and return to weighing mode turn the scale off and on again

Weighmaster

On the side of the display, you will notice a series of bars that increase as the load on the scale increases. This is our Weighmeter TM invention. It helps you know the remaining capacity on the scale and also will indicate an overload if one occurs. Please use the

Weighmeter TM to monitor your weighing loads and please do not overload this scale.

FREQUENTLY ASKED QUESTIONS

Does My Weigh iBalance have a counting feature?

Yes, it has a counting feature.

What batteries are required for My Weigh iBalance?

It comes with AC power adapter.

What is tabletop scale?

The tabletop scale is applicable in a wide range of fields and covers several professional segments. Additional tools can be ordered as well, including external printers, below-the-surface measurement tools, tripods, and density measurement systems.

What is the precision of a scale?

The precision of a number is its digit count. The scale of a number is the amount of digits to the right of the decimal point. For instance, the number 123.45 has a scale of 2 and a precision of 5.

Is it worth buying a smart scale?

Don’t base your life and death on the number because these scales can only provide an approximate indication of body composition. However, the scale can detect trends over time when you step on it under the same circumstances (such as the time of day and your level of hydration). A smart scale might help folks who are trying to lose weight stay motivated.

How can I tell if my scale is accurate?

Note the weight of a coin after placing it on the scale. Put one more nickel on the scale, and then record the updated weight. One additional nickel can be added to the scale; record the weight. If your scale is accurate, each increment should have resulted in a 5g increase in weight.

What is a tabletop balance used for?

A portable, quick, and accurate tabletop balancer. This sturdy and dependable balance is made to handle environmental adversity, food service wear and strain, and food processing wear and tear.

What is a platform scale?

Platform scales weigh the items loaded onto a flat platform, and then display the results. The platform’s job is to support the object during weighing and convey the object’s weight to the internal measurement equipment.

What is the benchtop scale?

A bench scale is a small scale that can be placed on top of a workstation or workbench. It is also referred to as a bench top scale, tabletop weight scale, or compact scale. Digital benchtop scales are utilized for more complex procedures and smaller weighing requirements where the operator must stand close to the scale.

What is the most accurate balance?

An analytical balance is a superior option for your laboratory if you need extreme accuracy. The precision of an analytical balance is between 0.0001 and 0.00001g. A top-loading balance will do just well in determining the precision of 0.001g if extreme accuracy is not necessary.

What is the purpose of the pilot scale?

Determining whether raw materials are continuously available that meets the requirements needed to make the product. Determining the necessary physical space and organizing relevant tasks for both immediate and long-term efficiency.

What is more accurate than a mass balance?

An extremely sensitive laboratory tool known as an analytical balance is capable of precisely measuring mass down to the sub-milligram range. The weighing capacity of analytical balances is between 100 and 500 g, and their readability ranges from 0.1 mg to 0.001 mg.

What calibration weight does the 6000g scale require?

6000g scale requires 5000g calibration weight.

References

Leave a comment

Your email address will not be published. Required fields are marked *