Munters RTS-2 Temperature Sensor
Specifications
- Product Name: RTS-2 Temperature Sensor
- Part Number: 918-01-00001
- Type: 30 Kohm thermistor
- Maximum cable length: 300 meter (984 feet)
- Typical accuracy: 0.3° C
- Maximum 25°C tolerance: ±3%
- Operating temperature: -40° to 70° C / -40° to 158° F
- Minimum wire size: 22 AWG ( 2 wire shielded cable)
Wiring
- Red cable: Input signal
- Black cable: COM port
Installation Recommendations
- Position the sensor as low as possible but high enough that the flock or swine cannot touch it.
- There should be 20 – 25 meters/65 – 80 feet between each sensor.
FAQs
- Q: What should I do if the RTS-2 Temperature Sensor is not providing accurate readings?
- A: If you encounter inaccuracies with the temperature readings, first check the wiring connections and ensure they are secure. Additionally, recalibrate the sensor following the calibration procedures outlined in the user manual.
- Q: Can the RTS-2 Temperature Sensor be used outdoors?
- A: The RTS-2 Temperature Sensor is designed for indoor use. For outdoor applications, consider using weatherproof housing to protect the sensor from environmental elements.
Documents / Resources
![]() |
Munters RTS-2 Temperature Sensor [pdf] Instructions RTS-2, 918-01-00001, 116913 R1.2, RTS-2 Temperature Sensor, RTS-2, Temperature Sensor, Sensor |