1. Introduzzjoni
This manual provides detailed instructions for the EBYTE M31-AXXXA000G 16DI Remote IO Module. This device is designed for industrial automation applications, supporting Modbus TCP and Modbus RTU protocols for data acquisition and control. It features an expandable design, allowing connection of up to 16 IO expansion modules to meet diverse functional requirements.
2. Prodott Aktarview
The EBYTE M31-AXXXA000G is a host module in the M31 series, offering 16 digital inputs (DI) and supporting both RS485 and Ethernet (RJ45) communication. It facilitates simultaneous access by up to 5 clients and supports various Modbus function codes (01/02/03/04/05/06/15/16). The module is built for reliability and ease of integration into existing Modbus systems.

Figura 2.1: Quddiem u ġenb view of the EBYTE M31-AXXXA000G Remote IO Module, showing its ports and indicators.

Figure 2.2: Dimensional drawing of the EBYTE M31-AXXXA000G Remote IO Module, indicating its length (110mm), width (40mm), and height (100mm).

Figure 2.3: Illustration showing multiple EBYTE Remote IO Modules connected, highlighting their modular design and expandability.

Figure 2.4: Image highlighting the module's robust design with anti-fungal, anti-humidity, and anti-salt spray properties, along with a close-up of its circuit board.
3. Setup
3.1 Immuntar
The M31-AXXXA000G module supports installation using positioning holes or guide rails. Ensure a secure mounting location that provides adequate ventilation and protection from environmental factors.
3.2 Wiring u Konnessjonijiet
Connect the module to your network via the RJ45 Ethernet port. For RS485 communication, connect the appropriate terminals. Ensure all power connections are correctly made according to the module's specifications.
3.3 Konfigurazzjoni tan-Netwerk
The module supports both DHCP and static IP configurations. Refer to the specific software tools or DIP switch settings for configuring the network parameters to match your system requirements.
3.4 Modbus Address Configuration
Custom Modbus addresses can be set for the module. This can be done either through dedicated configuration software or by using the integrated dial codes (DIP switches) on the device itself.

Figure 3.1: Image depicting the DIP switches on the EBYTE M31 module for quick Modbus address configuration without a host computer.
3.5 Expansion Modules
The M31-AXXXA000G host module can connect up to 16 IO expansion modules. Ensure proper physical connection and configuration of each expansion module according to its specific instructions to extend the system's capabilities.
4. Istruzzjonijiet Operattivi
4.1 Komunikazzjoni Modbus
The module supports standard Modbus TCP and Modbus RTU protocols. It can be integrated with various configuration software, PLCs, and HMI touch screens. The device allows simultaneous access by up to 5 clients and supports Modbus function codes 01, 02, 03, 04, 05, 06, 15, and 16.

Figure 4.1: Diagram showing the EBYTE M31 module's compatibility with HMI touch screens, configuration software, and PLCs within a Modbus system.
4.2 Baud Rate Configuration
The module supports 8 different baud rate configurations for RS485 communication. Select the appropriate baud rate to match your connected devices for stable data transmission.
4.3 Input Range Configuration
The module's analog input ranges are configurable, making it suitable for 0-20mA and 4-20mA sensors and transmitters.

Figure 4.2: Diagram illustrating the configurable input ranges for the module, supporting both 0-20mA and 4-20mA sensors/transmitters.
4.4 Using Upper Computer Software
Utilize the dedicated upper computer software for rapid debugging and parameter configuration of the module. This software provides an interface for monitoring DI status, DO state switching, AI input acquisition, and AO output range settings.

Figure 4.3: Screenshot of the upper computer software interface, demonstrating its use for rapid debugging and parameter configuration of the EBYTE M31 series modules.
5. Manutenzjoni
The EBYTE M31-AXXXA000G module is designed for stable and reliable performance with minimal user maintenance. It features a status diagnosis function that monitors the communication status of IO modules in real-time, aiding in system health checks.
The product undergoes 100% functional and aging tests prior to shipment. Its shell is coated with a conformal coating, providing anti-fungal, anti-humidity, and anti-salt spray properties, ensuring durability in various industrial environments.
Regularly inspect physical connections for any signs of wear or damage. Keep the module free from dust and debris to ensure optimal performance and heat dissipation.
6 Issolvi l-problemi
If you encounter issues with the EBYTE M31-AXXXA000G module, consider the following basic troubleshooting steps:
- Kontroll tal-Enerġija: Ensure the module is receiving adequate power and that power connections are secure.
- Verifika tal-Konnessjoni: Check all Ethernet and RS485 cable connections for proper seating and integrity.
- Issettjar tan-Netwerk: Verify that the IP address, subnet mask, and gateway settings are correct for your network, especially if using a static IP.
- Indirizz Modbus: Confirm that the Modbus address is correctly set, either via DIP switches or software, and does not conflict with other devices on the bus.
- Rata Baud: For RS485, ensure the baud rate matches that of the connected master device.
- Indikaturi tal-Istat: Observe the module's status indicators (PWR, LINK, STA, etc.) for any error codes or abnormal behavior. Refer to the product documentation for indicator meanings.
- Dijanjostika tas-Softwer: Utilize the upper computer software's diagnostic features to monitor communication status and identify potential issues.
- Moduli ta' Espansjoni: If using expansion modules, ensure they are correctly connected and configured.
If the problem persists after performing these checks, consult the manufacturer's technical support.
7. Speċifikazzjonijiet
| Karatteristika | Deskrizzjoni |
|---|---|
| Brand | EBYTE |
| Numru tal-Mudell | M31-AXXXA000G |
| Tip | Remote IO Host Module |
| Inputs Diġitali (DI) | 16 |
| Inputs Analoġiċi (AI) | Not applicable (for this host model) |
| Outputs Diġitali (DO) | Not applicable (for this host model) |
| Outputs Analoġiċi (AO) | Not applicable (for this host model) |
| Interfaċċa tan-Netwerk | RJ45 Ethernet |
| Port Serjali | RS485 |
| Protokolli Appoġġjati | Modbus TCP, Modbus RTU |
| Aċċess għall-Klijent | Up to 5 simultaneous clients |
| Kodiċi tal-Funzjoni Modbus | 01, 02, 03, 04, 05, 06, 15, 16 |
| Baud Rate Configurations | 8 għażla |
| Konfigurazzjoni IP | DHCP, IP Statiku |
| Kapaċità ta 'Espansjoni | Supports up to 16 IO expansion modules |
| Protezzjoni Ambjentali | Anti-Fungal, Anti-Humidity, Anti-Salt Spray |

Figure 7.1: Table comparing specifications and parameters across various M31 series host and expansion modules, detailing digital inputs, analog inputs, digital outputs, analog outputs, network, and serial port options.
8. Garanzija u Appoġġ
For warranty information, please refer to the terms and conditions provided by the seller or contact EBYTE directly. Technical support and further assistance can be obtained through the official EBYTE channels or your product distributor.