1. Introduzzjoni
The MOXA UPort 1250 is a 2-port USB-to-Serial hub designed for industrial and commercial applications requiring reliable serial communication. It provides two RS-232/422/485 serial ports, enabling connection of various serial devices to a host computer via a single USB 2.0 interface. This device supports high-speed data transmission up to 921.6 Kbps and features 15KV ESD protection for enhanced durability in challenging environments.
This manual provides detailed instructions for the installation, operation, and maintenance of your UPort 1250 hub.
2. Karatteristiċi tal-prodott
- USB 2.0 ta' Veloċità Għolja għal trasmissjoni USB sa 480 Mbps.
- Two independent RS-232/422/485 serial ports.
- Maximum baud rate of 921.6 Kbps for fast data transmission.
- FIFO ta' 128 byte u kontroll tal-fluss tal-ħardwer/softwer on-chip.
- 15KV ESD protection for all serial signals.
- Locking power jack for secure power connection.
- 15N high retention type B USB connector.
- Jappoġġja l-Utilità COM b'bażi fissa għall-issettjar tan-numri inizjali tal-port COM estiż.
- Driver support for Windows, WinCE, and Linux operating systems.
- LED indicators for easy monitoring of USB and serial port activity.
3. Kontenut tal-Pakkett
Ivverifika li l-pakkett tiegħek fih l-oġġetti li ġejjin:
- MOXA UPort 1250 USB-to-Serial Hub
- Cable USB tat-Tip A għal Tip B
- Power adapter (if applicable, check specific model variant)
- Documentation CD or link to driver download
- Gwida ta 'Installazzjoni Mgħaġġla
Jekk xi wieħed minn dawn l-oġġetti huwa nieqes jew bil-ħsara, jekk jogħġbok ikkuntattja lill-bejjiegħ tiegħek immedjatament.
4. Deskrizzjoni tal-Hardware

Figura 1: Quddiem view of the MOXA UPort 1250, showing USB and Active LEDs, P1 and P2 indicators for RS-232, RS-422, 4W RS-485, 2W RS-485, and TxD/RxD, along with Port 1 and Port 2 DB9 connectors.

Figura 2: Angolat view of the MOXA UPort 1250, illustrating the two DB9 serial ports (Port 1 and Port 2) and the overall compact design of the hub.
Indikaturi LED:
- USB: Indicates USB connection status. Lit when connected to a host.
- Attiv: Indicates data activity on the USB interface.
- P1/P2 (RS-232/422/485, TxD/RxD): These LEDs indicate the current serial mode and data transmission/reception activity for each port.
Konnetturi:
- Port USB: Type B connector for connection to the host computer.
- Serial Ports (Port 1, Port 2): DB9 male connectors for RS-232/422/485 serial devices.
- Jack tal-Enerġija: Locking power jack for external power adapter (if required by application or specific model).
5. Setup and Driver Installation
5.1 Installazzjoni tas-sewwieq
Before connecting the UPort 1250 to your computer, install the necessary drivers. Drivers are available for Windows, WinCE, and Linux operating systems. Refer to the included documentation or the Moxa website for the latest driver downloads and installation instructions specific to your operating system.
- Download the appropriate driver package from the Moxa official websit.
- Oħroġ is-sewwieq files to a temporary directory.
- Follow the on-screen instructions provided by the driver installer.
- Ibda mill-ġdid il-kompjuter tiegħek jekk tintalab.
5.2 Konnessjoni tal-Ħardwer
- Connect the USB Type B port on the UPort 1250 to an available USB port on your host computer using the provided USB cable. The "USB" LED on the hub should illuminate.
- If external power is required, connect the power adapter to the locking power jack on the UPort 1250 and then to a power outlet.
- Connect your serial devices to the DB9 serial ports (Port 1 and Port 2) on the UPort 1250. Ensure correct pin assignments for RS-232, RS-422, or RS-485 as per your device's requirements.
- After successful driver installation and hardware connection, the operating system should recognize the new COM ports.
5.3 COM Port Utility
The UPort 1250 supports a fixed-base COM Utility. This utility allows you to configure and manage the assigned COM port numbers, which can be useful in environments where specific COM port assignments are required for legacy applications or system consistency. Refer to the Moxa software documentation for detailed instructions on using this utility.
6. Istruzzjonijiet Operattivi
6.1 Serial Communication Modes
The UPort 1250 supports RS-232, RS-422, and RS-485 communication modes. The mode is typically auto-detected or configured via software settings depending on the connected device and driver capabilities. Ensure your serial device is configured to match the UPort's port settings.
- RS-232: Standard serial communication for point-to-point connections.
- RS-422: Differential signaling for longer distances and higher noise immunity, typically point-to-multipoint.
- RS-485 (2-wire/4-wire): Multi-drop communication for connecting multiple devices on a single bus. The UPort 1250 supports both 2-wire and 4-wire configurations.
6.2 Trażmissjoni tad-Data
Once drivers are installed and devices are connected, your application software can access the serial ports as standard COM ports. Configure your application with the correct COM port number, baud rate (up to 921.6 Kbps), data bits, stop bits, and parity settings to match your serial device.
The TxD/RxD LEDs for each port will flash to indicate data transmission (TxD) and reception (RxD) activity, providing visual confirmation of communication.
7. Manutenzjoni
- Tindif: Uża drapp artab u niexef biex tnaddaf il-barra tal-apparat. Tużax prodotti tat-tindif likwidi jew aerosol.
- Ambjent: Operate the UPort 1250 within its specified environmental conditions (temperature, humidity) to ensure optimal performance and longevity.
- Protezzjoni ESD: The device features 15KV ESD protection. However, always handle the device and connected cables with care to minimize static discharge, especially in dry environments.
- Firmware/Driver Updates: Iċċekkja l-Moxa perjodikament website for updated drivers or firmware that may improve performance or add new features.
8 Issolvi l-problemi
- Apparat Mhux Rikonoxxut:
- Ensure the USB cable is securely connected to both the UPort 1250 and the host computer.
- Verify that the USB LED on the UPort 1250 is illuminated.
- Check if the drivers are correctly installed in your operating system's Device Manager (Windows) or equivalent. Reinstall drivers if necessary.
- Ipprova qabbad ma 'port USB differenti fuq il-kompjuter tiegħek.
- L-ebda Komunikazzjoni ma' Apparat Serjali:
- Confirm that the serial device is properly connected to the UPort 1250's serial port.
- Verify that your application software is configured with the correct COM port number, baud rate, data bits, stop bits, and parity settings.
- Check the TxD/RxD LEDs on the UPort 1250 for activity. If no LEDs flash during communication attempts, there might be an issue with the serial device or its connection.
- Ensure the correct serial mode (RS-232/422/485) is selected or auto-detected.
- Intermittent Connection/Data Loss:
- Iċċekkja għal konnessjonijiet tal-kejbil maħlula.
- Ensure the power supply is stable and correctly connected (if external power is used).
- Minimize electromagnetic interference by keeping the device away from strong electrical fields.
9. Speċifikazzjonijiet
| Mudell | UPort 1250 |
| Interface USB | USB 2.0 Hi-Speed (480 Mbps) |
| Portijiet Serjali | 2 (RS-232/422/485) |
| Konnetturi | USB Type B, DB9 Male (x2) |
| Rata Baud | 50 bps sa 921.6 Kbps |
| Protezzjoni ESD | 15 KV (all serial signals) |
| FIFO | 128-byte |
| Kontroll tal-Fluss | Hardware (RTS/CTS), Software (XON/XOFF) |
| Sistemi Operattivi | Windows, WinCE, Linux |
| Dimensjonijiet (L x W x H) | 3 x 4 x 1 pulzieri |
| Piż | 13 uqija |
| Manifattur | Moxa Inc. |
10. Garanzija u Appoġġ
Moxa products are designed for reliability and performance. For information regarding product warranty, technical support, and service, please refer to the official Moxa website or contact your local Moxa distributor. Ensure you have your product model number (UPort 1250) and serial number ready when seeking support.
Uffiċjali tal-Moxa Websit: www.moxa.com