1. Pengenalan

This user manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Broadcom MegaRAID 9560-16i Storage Controller. This high-performance RAID controller is designed to manage various storage devices, offering robust data protection and efficient data access for server environments.

2. Produk Lebihview

The Broadcom MegaRAID 9560-16i is a 16-channel storage controller supporting SATA 6Gb/s, SAS 12Gb/s, and PCIe 4.0 (NVMe) interfaces. It supports multiple RAID levels including 0, 1, 5, 6, 10, 50, 60, and JBOD, providing flexible storage solutions. The controller features a PCIe 4.0 x8 interface for high bandwidth connectivity.

2.1 Ciri-ciri Utama

2.2 Imej Produk

Broadcom MegaRAID 9560-16i Storage Controller card

Figure 2.1: Broadcom MegaRAID 9560-16i storage controller. This image displays the green circuit board with a large black heatsink covering the main processor, and multiple SAS/SATA ports on the right side. The card also features a PCIe connector at the bottom and a metal bracket for mounting.

3. Persediaan dan Pemasangan

3.1 Keperluan Sistem

3.2 Pemasangan Perkakasan

  1. Sistem Matikan Kuasa: Ensure the computer system is completely powered off and disconnected from the power source.
  2. Casis terbuka: Open the computer chassis to access the motherboard and expansion slots.
  3. Cari Slot PCIe: Identify an available PCIe 4.0 x8 slot.
  4. Insert Controller: Carefully align the Broadcom MegaRAID 9560-16i controller with the PCIe slot and firmly press it down until it is securely seated.
  5. Kad Selamat: Secure the controller card with the retention mechanism or screw provided by your chassis.
  6. Sambungkan Kabel: Connect your SAS/SATA/NVMe drives to the appropriate ports on the controller using compatible cables.
  7. Tutup Casis: Close the computer chassis and reconnect the power.

3.3 Pemasangan Pemandu

After hardware installation, power on the system. You may need to install the appropriate drivers for the Broadcom MegaRAID 9560-16i controller. Drivers are typically available on the Broadcom official support website. Follow the driver installation instructions provided by Broadcom for your specific operating system.

4. Arahan Operasi

4.1 Tatarajah Awal

Upon successful driver installation, the controller will be recognized by your operating system. Initial configuration, such as creating RAID arrays, is typically performed through the controller's BIOS utility during system boot-up or via a software utility provided by Broadcom (e.g., MegaRAID Storage Manager).

4.2 Creating RAID Arrays

  1. Access the RAID controller's configuration utility during system startup (usually by pressing a specific key like Ctrl+R or Ctrl+H when prompted).
  2. Select the drives you wish to include in the array.
  3. Choose the desired RAID level (e.g., RAID 0, 1, 5, 6, 10, 50, 60, or JBOD) based on your performance and redundancy requirements.
  4. Configure array parameters such as stripe size and cache policy.
  5. Save the configuration and exit the utility. The system will then recognize the new logical drive.

4.3 Monitoring and Management

Use the Broadcom MegaRAID Storage Manager (MSM) or a similar utility to monitor the health of your RAID arrays and connected drives. This software allows you to view array status, perform maintenance tasks, and receive alerts for potential issues.

5. Penyelenggaraan

6. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Pengawal tidak dikesan oleh sistem.Incorrectly seated in PCIe slot; incompatible slot; power issue; missing drivers.Ensure controller is fully seated. Try a different PCIe slot. Verify power connections. Install or update drivers.
Drives not recognized by controller.Loose or faulty cables; incompatible drives; drive failure.Check all data and power cables. Ensure drives are compatible. Test drives individually if possible.
Tatasusunan RAID terdegradasi atau gagal.Drive failure; improper configuration.Identify and replace the failed drive. Rebuild the array using the RAID management utility. Review tetapan konfigurasi.
System performance issues.Outdated drivers/firmware; high I/O load; insufficient system resources.Update drivers and firmware. Optimize RAID array settings. Ensure adequate system RAM and CPU.

For more detailed troubleshooting, refer to the official Broadcom support documentation or contact Broadcom technical support.

7. Spesifikasi

Nombor Model05-50077-00
JenamaBROADCOM
Dimensi Produk22 x 8 x 3cm; 252g
Antara Muka PerkakasanSAS, SATA, PCIe 4.0 (NVMe)
Saluran16
Tahap RAID Disokong0, 1, 5, 6, 10, 50, 60, JBOD
Antara Muka HosPCIe 4.0 x8
Peranti SerasiPersonal Computer (Servers)
UPC830343007462
ASINB08B52PR5Q
Tarikh Mula-mula Tersedia18 April 2020

8. Waranti dan Sokongan

The Broadcom MegaRAID 9560-16i Storage Controller is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Broadcom webtapak.

For technical support, driver downloads, firmware updates, and additional resources, please visit the Broadcom support portal. It is recommended to have your product model number (05-50077-00) and serial number ready when contacting support.

Dokumen Berkaitan - 05-50077-00

Praview Panduan Pemilihan Penyelesaian Storan Broadcom: HBA, MegaRAID, SafeStore, CacheCade
Comprehensive selection guide for Broadcom's storage solutions, including Host Bus Adapters (HBAs), MegaRAID controller cards, SafeStore software, CacheCade Pro 2.0, and various SAS, SATA, and U.2 enabled cables for enterprise data centers.
Praview Broadcom CVPM02, CVPM05, CVFM04 User Guide: Installation and Management
Comprehensive user guide for Broadcom CVPM02, CVPM05 Power Modules and CVFM04 Cache Module. Learn about installation, configuration, monitoring, and specifications for MegaRAID cache backup solutions.
Praview Panduan Pemasangan Penyesuai Bas Hos Broadcom Emulex Keluaran 14.4
Panduan pemasangan ini (Keluaran 14.4) daripada Broadcom menyediakan arahan terperinci untuk menyediakan Penyesuai Bas Hos Emulex (HBA), termasuk model LPe38100, LPe37100, LPe36000, LPe35000, LPe32000 dan siri LPe31000. Ia merangkumi pemasangan, keserasian, ciri utama, spesifikasi dan maklumat kawal selia.
Praview Emulex Drivers for VMware ESXi User Guide Release 14.4
This user guide provides comprehensive instructions for installing and configuring Emulex drivers for VMware ESXi, supporting both FC and NVMe over FC protocols. Learn about driver parameters, installation, troubleshooting, and compatibility for Emulex HBAs.
Praview BCM56070 Hardware Design Guidelines
This document provides hardware design guidelines for the Broadcom BCM56070 family of devices, detailing electrical characteristics for high-speed I/O interfaces, connection diagrams, and routing examples.
Praview Broadcom Emulex Fibre Channel Host Bus Adapters Installation Guide
Comprehensive installation guide for Broadcom Emulex Fibre Channel Host Bus Adapters (HBAs), covering HBA identification, bracket changes, firmware settings, installation, media attachment, power application, and LED status interpretation. Release 12.8.