1. Pengenalan
This manual provides comprehensive instructions for the setup, operation, and maintenance of the ADC Adview 2 Modular Diagnostic Station. This device is designed for clinical-grade blood pressure and temperature measurements, offering advanced features for healthcare professionals.
Iklan ituview 2 integrates advanced Advantage BP technology from SunTech Medical, providing accurate and reliable readings. Its compact design and user-friendly interface make it suitable for various clinical environments.
2. Produk Lebihview

Rajah 1: The ADC Adview 2 Modular Diagnostic Station, showcasing its integrated handle, large digital display, and the attached blood pressure cuff with its coiled tubing.
Ciri-ciri Utama:
- Clinical-grade Advantage BP technology from SunTech Medical.
- Contemporary, compact design with an integrated handle.
- Easy-to-read display for clear data visualization.
- Manual blood pressure mode for real-time verification.
- Customizable average mode options.
- Next-generation EMR ready with HL7 messaging for electronic data transfer.
- Network enabled with built-in Ethernet or optional Wi-Fi.
- Lithium-ion power for longer-lasting battery life.
- Built-in memory with up to 99 charting sessions.
- New Pediatric Mode for accurate measurements on younger patients.
- Firmware boleh dinaik taraf.
- Includes two Adcuff+ cuffs: Adult and Large Adult.
3. Arahan Persediaan
- Membongkar: Carefully remove the Adview 2 Diagnostic Station and all accessories from the packaging. Verify that all components listed in the packing list are present, including the main unit, power cord, and two Adcuff+ cuffs (Adult and Large Adult).
- Sambungan Kuasa: Connect the provided power cord to the power input port on the back of the unit. Plug the other end into a standard electrical outlet. The device is powered by corded electric and features a lithium-ion battery for portable use.
- Cuff Attachment: Select the appropriate Adcuff+ cuff (Adult or Large Adult) for the patient. Connect the cuff tubing to the designated port on the side of the Adview 2 unit. Ensure a secure connection.
- Caj Permulaan: For optimal battery performance, fully charge the device before its first use. The battery indicator on the display will show charging status.
- Persediaan Rangkaian (Pilihan): If network connectivity is desired for EMR integration, connect an Ethernet cable to the unit's Ethernet port or configure optional Wi-Fi settings via the device's menu. Refer to the on-screen prompts for network configuration.
4. Arahan Operasi
4.1 Menghidupkan/Mematikan
To power on the device, press and hold the power button located on the front panel until the display illuminates. To power off, press and hold the power button again until the display shuts down.
4.2 Mengambil Pengukuran Tekanan Darah
- Ensure the patient is seated comfortably with their arm supported at heart level.
- Wrap the appropriate size Adcuff+ cuff snugly around the patient's bare upper arm, ensuring the artery marker is aligned with the brachial artery.
- Press the START/STOP button on the device. The cuff will inflate, and the measurement will begin automatically.
- Kekal diam dan senyap semasa pengukuran.
- Once the measurement is complete, the systolic, diastolic, and pulse rate readings will be displayed on the LCD screen. The cuff will automatically deflate.
4.3 Manual Blood Pressure Mode
The manual BP mode allows for real-time verification of readings. To activate, navigate to the manual mode option using the control knob and follow the on-screen prompts for inflation and deflation control.
4.4 Pediatric Mode
For accurate measurements on younger patients, activate the Pediatric Mode through the device's menu settings. This mode adjusts the measurement algorithm for pediatric physiology.
4.5 Pengurusan Data
Iklan ituview 2 stores up to 99 charting sessions in its built-in memory. Review past readings by navigating through the memory function on the display. Data can be transferred to EMR systems via Ethernet or Wi-Fi using HL7 messaging.
5. Penyelenggaraan
5.1 Pembersihan
Regularly clean the exterior of the Adview 2 unit with a soft, damp cloth. Use a mild, non-abrasive cleaner if necessary. Do not immerse the device in water or use harsh chemicals. Clean the cuffs according to their specific care instructions.
5.2 Penjagaan Bateri
The device uses a lithium-ion battery. To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will not be used for an extended period.
5.3 Kemas Kini Perisian Tegar
Iklan ituview 2 is firmware upgradeable. Periodically check the manufacturer's website or contact technical support for information on available firmware updates to ensure optimal performance and access to new features.
6. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Peranti tidak dihidupkan. | Low battery or power cord not connected. | Connect the power cord and ensure it is plugged into a live outlet. Allow time for battery to charge if depleted. |
| Inaccurate BP readings. | Incorrect cuff size, improper cuff placement, or patient movement. | Ensure correct cuff size is used and properly applied. Instruct patient to remain still and quiet during measurement. |
| Cuff tidak mengembang. | Cuff tubing not securely connected or a leak in the system. | Check all tubing connections. Inspect cuff and tubing for any visible damage or leaks. |
| No data transfer to EMR. | Network connectivity issues or incorrect EMR settings. | Verify Ethernet cable connection or Wi-Fi settings. Consult IT department for EMR configuration. |
7. Spesifikasi
- model: Adview 2 Modular Diagnostic Station Bp/Temp
- Jenama: ADC
- ASIN: B0735PQNMD
- UPC: 634782084677
- Sumber Kuasa: Corded Electric (with Lithium-ion battery)
- Jenis Paparan: LCD
- Komponen yang Disertakan: Main unit, Power Cord, Adult Adcuff+, Large Adult Adcuff+
- Julat Umur (Penerangan): Adult (with Pediatric Mode)
- Ciri Bahan: Tahan lasak
- Pertama Tersedia: 18 Jun 2017
8. Waranti dan Sokongan
For warranty information and technical support, please refer to the official ADC website or contact ADC customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.
Untuk bantuan lanjut, anda boleh melawati ADC Store on Amazon or contact your authorized distributor.