1. Pengenalan
1.1 Produk Selesaiview
The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.
1.2 Maklumat Keselamatan
Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.
- Sentiasa putuskan bekalan elektrik sebelum melakukan sebarang pemasangan atau penyelenggaraan.
- Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
- Sahkan bahawa bekalan kuasa voltage matches the pump's requirements (230 Volts AC).
- Do not operate the pump with damaged cables or connections.
- Wear appropriate personal protective equipment (PPE) when handling chemicals or performing maintenance.
2. Persediaan dan Pemasangan
2.1 Memasang Pam
Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.
2.2 Sambungan Elektrik
The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.
2.3 Fluid Connections
Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.
3. Arahan Operasi
3.1 Permulaan Permulaan
- Ensure all fluid connections are secure and the pump is properly mounted.
- Verify that the fluid source is available and the discharge line is correctly routed.
- Plug the pump into the power supply.
3.2 Flow Regulation
The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).
4. Penyelenggaraan
4.1 Penyelenggaraan Am
- Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
- Check all connections for leaks and tighten if required.
- Keep the pump's exterior clean and free from dust and debris.
4.2 Pembersihan
To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.
5. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pam tidak bermula | Tiada bekalan kuasa Kabel kuasa rosak | Periksa sambungan kuasa dan alur keluar Inspect and replace cable if damaged |
| Tiada aliran bendalir | Tiub bengkok atau tersumbat Penapis masuk tersumbat Potentiometer set to 0% | Inspect and clear tubing Bersihkan atau ganti penapis masuk Adjust potentiometer to desired flow rate |
| Aliran yang tidak konsisten | Udara dalam talian Worn tubing | Keluarkan udara dari sistem Replace peristaltic tubing |
| Kebocoran pada sambungan | Sambungan longgar Damaged seals/tubing | Ketatkan semua sambungan Inspect and replace seals or tubing |
6. Spesifikasi Teknikal
| Spesifikasi | Nilai |
|---|---|
| Jenama | Astralpool |
| Nombor Model | 57178 |
| Dimensi Produk (L x W x H) | 23 x 11 x 13 cm |
| Berat badan | 900 gram |
| Voltage | 230 Volt (AC) |
| Kadar Aliran | Up to 12 L/H (continuously adjustable) |
| Tekanan Maksimum | 1 bar |