1. Pengenalan
This manual provides comprehensive instructions for the proper handling, installation, and maintenance of Armstrong World Industries 816A Mineral Fiber Ceiling Tiles. These tiles are designed for use in suspended ceiling grid systems, offering both acoustic performance and a clean aesthetic. Adhering to these guidelines will ensure optimal performance and longevity of your ceiling system.
2. Setup and Pre-Installation
2.1 Alat dan Bahan yang Diperlukan
- Utility knife or ceiling tile cutter
- Pita pengukur
- Straightedge
- Cermin mata keselamatan
- Sarung tangan kerja
- Pensel
- Appropriate suspended ceiling grid system components
2.2 Penyediaan Tapak
- Pastikan kawasan pemasangan bersih, kering dan bebas daripada serpihan.
- Maintain a consistent room temperature and humidity level for at least 24 hours before, during, and after installation to allow tiles to acclimate.
- Inspect all ceiling tiles for any visible damage or defects before installation. Do not install damaged tiles.
3. Pemasangan
The Armstrong 816A ceiling tiles are designed for a standard lay-in installation within a suspended grid system. Follow the grid system manufacturer's instructions for grid assembly prior to tile installation.
3.1 Lay-In Installation Steps
- Titik Mula: Begin installing tiles from the center of the room or a designated starting point to ensure a balanced appearance.
- Placing Tiles: Gently lift each tile at an angle and carefully lower it into the grid opening. Ensure the tile rests evenly on all four grid flanges.
- Cutting Edge Tiles: For perimeter tiles or around fixtures, measure the required size accurately. Use a utility knife and a straightedge to cut the mineral fiber tile. Score the tile deeply on the finished side, then snap it along the score line. For a cleaner cut, score the back side as well.
- Pengendalian: Handle tiles by their edges to avoid damaging the face. Wear clean gloves to prevent transferring dirt or oils to the tile surface.

This image displays the surface texture and edge profile of the Armstrong 816A ceiling tile, highlighting its white, textured finish and square edge design, ready for lay-in installation.
4. Pertimbangan Penggunaan
While ceiling tiles do not have operational functions, certain considerations ensure their optimal performance and appearance over time.
- Keadaan Persekitaran: Avoid exposing tiles to extreme humidity or temperature fluctuations, as this can lead to warping or sagging.
- Pengagihan Berat: Do not place excessive weight directly on the ceiling tiles. Any items requiring suspension from the ceiling should be supported by the grid system or structural elements above.
- Perlindungan Kesan: Protect tiles from direct impact or sharp objects, which can cause dents or punctures.
5. Penyelenggaraan
Regular maintenance helps preserve the appearance and integrity of your Armstrong 816A ceiling tiles.
5.1 Pembersihan
- Berhabuk: Use a soft, dry cloth or a duster to remove light dust.
- Memvakum: For more accumulated dust, use a vacuum cleaner with a soft brush attachment on a low setting.
- Pembersihan Tempat: For minor marks, gently wipe with a slightly damp cloth using only water. Avoid harsh chemicals or abrasive cleaners, as these can damage the tile surface. Test any cleaning method on an inconspicuous area first.
5.2 Repair and Replacement
- Minor Damage: Small scuffs or marks may sometimes be carefully touched up with a matching white paint, if approved by the manufacturer.
- Tile Replacement: For significantly damaged, stained, or warped tiles, the most effective solution is replacement. Gently lift the damaged tile out of the grid and insert a new one following the installation steps.
6. Penyelesaian masalah
This section addresses common issues that may arise with ceiling tiles.
| Isu | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Tiles are sagging or warping | High humidity, water damage, improper installation, excessive weight on tiles. | Address humidity issues, repair leaks, ensure proper grid support, replace damaged tiles. |
| Perubahan warna atau pewarnaan | Water leaks, smoke, dirt accumulation, mold/mildew. | Identify and fix source of leaks, clean or replace stained tiles, improve ventilation. |
| Tiles do not fit properly in grid | Incorrect tile size, improperly installed grid, tile expansion/contraction. | Verify tile dimensions, check grid alignment and squareness, allow tiles to acclimate before installation. |
7. Spesifikasi
Key specifications for the Armstrong 816A Mineral Fiber Ceiling Tile:
| Ciri | Perincian |
|---|---|
| Jenama | Armstrong |
| Nombor Model | 816A |
| bahan | Mineral Fiber |
| Saiz | 24 x 24 inci |
| Ketebalan Item | 5/8 inches (0.63 Inches) |
| warna | putih |
| Jenis Selesai | Bertekstur |
| Jenis Pemasangan | Lay-In |
| Gaya Tepi | Tepi Persegi |
| Berat Barang (setiap bungkusan) | 49 pounds (for PK 12) |
| UPC | 042369408660 |
| Tahap Ketahanan Air | Bukan Tahan Air |
8. Waranti dan Sokongan
Armstrong World Industries provides a manufacturer's warranty for its products. For specific warranty details, terms, and conditions, please refer to the official Armstrong World Industries webtapak atau hubungi sokongan pelanggan mereka secara langsung. Simpan resit pembelian anda sebagai bukti pembelian.
For technical assistance, product inquiries, or to report any issues, please contact Armstrong World Industries customer service.