1. Pengenalan
Thank you for choosing the ADC ADTEMP II Digital Thermometer, Model 413B-00. This compact and reliable thermometer is designed for accurate temperature measurement. Please read this manual thoroughly before use to ensure proper operation, maintenance, and to achieve the most accurate results.
2. Produk Lebihview

The image shows the ADC ADTEMP II Digital Thermometer, a white, pen-shaped device with a digital display showing '98.6 °F'. It is accompanied by its clear plastic protective case, which has the 'ADC AMERICAN DIAGNOSTIC CORPORATION' logo printed on it. The thermometer features a blue cap at the end opposite the probe.
Ciri-ciri Utama:
- Accurate digital temperature readings.
- Compact size, under 5 inches long, for easy handling and storage.
- Auto-off function to conserve battery life.
- Clear plastic case included for sanitary storage.
- Measurement range: 90°F - 109.9°F (32°C - 43.9°C).
Apa yang Termasuk:
- ADC ADTEMP II Digital Thermometer
- Protective scabbard carry case
3. Persediaan dan Persediaan
- Periksa Peranti: Before first use, carefully inspect the thermometer for any damage. Do not use if damaged.
- Bersihkan Termometer: Before and after each use, clean the thermometer probe as described in the "Maintenance and Cleaning" section.
- Hidupkan kuasa: Press the power button (usually located near the display) to turn on the thermometer. A short beep will sound, and the display will show all segments briefly, followed by the last measured temperature or "Lo" if the ambient temperature is below 90°F (32°C).
- Select Measurement Unit (if applicable): Some models allow switching between Fahrenheit (°F) and Celsius (°C). Refer to the device's specific instructions for this function, usually by holding the power button during startup.
4. Arahan Operasi
The ADTEMP II thermometer can be used for oral, rectal, or axillary (underarm) temperature measurements. Always ensure the probe is clean before use.
4.1 Oral Measurement (Recommended for Adults and Older Children)
- Place the probe tip under the tongue as close to the heat pocket as possible.
- Close your mouth and hold the thermometer in place with your lips and fingers. Avoid biting the thermometer.
- Hold the thermometer until a series of beeps indicates the measurement is complete (approximately 60 seconds).
- Baca suhu yang dipaparkan.
4.2 Rectal Measurement (Recommended for Infants and Young Children)
- Apply a water-soluble lubricant to the probe tip.
- Gently insert the probe tip no more than 1/2 inch (1.3 cm) into the rectum. Do not force the thermometer.
- Hold the thermometer in place until a series of beeps indicates the measurement is complete (approximately 60 seconds).
- Baca suhu yang dipaparkan.
4.3 Axillary (Underarm) Measurement (Less Accurate, Use as a Screening Method)
- Letakkan hujung probe di tengah ketiak.
- Ensure the arm is pressed firmly against the body to hold the thermometer in place.
- Hold the thermometer until a series of beeps indicates the measurement is complete (approximately 5-10 minutes). Note: Axillary measurements take longer and are generally less accurate than oral or rectal methods.
- Baca suhu yang dipaparkan.
4.4 Selepas Pengukuran
- Turn off the thermometer by pressing the power button, or it will automatically shut off after approximately 10 minutes of inactivity to conserve battery.
- Clean the thermometer as per the "Maintenance and Cleaning" section.
- Simpan termometer dalam bekas pelindungnya.
5. Penyelenggaraan dan Pembersihan
5.1 Membersihkan Termometer
It is crucial to clean and disinfect the thermometer before and after each use to prevent cross-contamination.
- Wipe the probe tip and shaft with a soft cloth dampened with 70% isopropyl alcohol or a mild soap and water solution.
- Rinse the probe tip with cool water (do not immerse the entire thermometer).
- Keringkan dengan teliti dengan kain bersih dan lembut.
- Do not use harsh detergents, abrasive cleaners, or immerse the entire thermometer in water or cleaning solutions.
5.2 Penggantian Bateri
The ADTEMP II thermometer uses a button cell battery. When the battery symbol appears on the display, it's time to replace the battery.
- Locate the battery compartment cover, usually at the end opposite the probe.
- Carefully remove the cover (a small screwdriver may be needed).
- Remove the old battery and insert a new one of the same type (e.g., LR41 or SR41), ensuring correct polarity (+/-).
- Gantikan penutup petak bateri dengan selamat.
- Buang bateri lama mengikut peraturan tempatan.
5.3 Penyimpanan
- Store the thermometer in its protective case when not in use.
- Simpan di tempat yang sejuk dan kering, jauh daripada cahaya matahari langsung dan suhu yang melampau.
- Jauhkan daripada kanak-kanak.
6. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| "Lo" atau "Hai" dipaparkan | Temperature is outside the measurement range (below 90°F/32°C or above 109.9°F/43.9°C). | Ensure proper placement of the thermometer. If "Lo" appears, the ambient temperature might be too low; try taking a measurement in a warmer environment. If "Hi" appears, seek medical attention if fever is suspected. |
| "Err" displayed | Ralat pengukuran atau kerosakan peranti. | Matikan termometer dan kemudian hidupkan semula. Jika ralat berterusan, hubungi khidmat pelanggan. |
| Blank display or faint readings | Bateri lemah. | Replace the battery as described in the "Battery Replacement" section. |
| Slow or inconsistent readings | Improper placement or movement during measurement. | Ensure the thermometer is held steadily and correctly positioned according to the chosen measurement method. |
7. Spesifikasi
- model: 413B-00
- Julat Pengukuran: 90°F - 109.9°F (32°C - 43.9°C)
- Jenis Paparan: digital
- Sumber Kuasa: Battery Powered (Button Cell)
- Matikan Auto: Ya, untuk menjimatkan hayat bateri
- Komponen yang Disertakan: Scabbard carry case
- Bahan: plastik
- warna: putih
- Dimensi: Lebih kurang 4.69 x 3.03 x 0.71 inci (dibungkus)
- Berat: Approximately 0.01 ounces (packaged)
- Pengeluar: ADC (American Diagnostic Corporation)
8. Waranti dan Sokongan
ADC (American Diagnostic Corporation) products are manufactured to high standards. For specific warranty information, please refer to the warranty card included with your product or visit the official ADC website. For technical support, replacement parts, or service inquiries, please contact ADC customer service directly.
Maklumat Hubungan: Please refer to the packaging or the official ADC webtapak untuk butiran hubungan terkini.