Product Usage Instructions

I/O Introduction:

The Control Box CB4M includes AC power cord, hand controls, and actuators.

Operation Guide for CB4M:

Press the UP/DOWN control button to move the actuator. Release the button to stop the actuator immediately.

Buttons and Operations

  • Actuator #1: Extend/Retract
  • Actuator #2: Extend/Retract
  • Actuator #3: Extend/Retract
  • Actuator #4: Extend/Retract

Installation & Operation for CB4M-B & CB4M-S:

Precautions Before Installation:

Complete electrical connections and perform stroke learning function before mechanical installation.

Learning and Operating Guide:

For CB4M-B:

Connect all actuators properly to enable learning process. Press specific buttons for automatic learning.

For CB4M-S:

Ensure all actuators are connected correctly. Follow specific button combinations for automatic learning and positioning.

General Operation for CB4M-S:

  • Press and hold button to move table up.
  • Press and hold button to move table down.
  • Standby mode: Display turns off after 20 seconds of inactivity.
  • Memory Function: Set desired height, hold button for 2 seconds, then press another button to save position.

FAQ

Q: How do I reset the system if the actuators are not responding correctly?

A: Perform a system reset by disconnecting the power source for a few minutes, then reconnect and reattempt operation.

  • Revision 2024.08_V2.0

Technical changes may be made to improve the product without notice!

I/O Introduction

CB4MMOTECK-CB4M-Control-Box-fig (1)

CB4M-B / CB4M-SMOTECK-CB4M-Control-Box-fig (2)

Operation Guide for CB4M

When the UP/DOWN control button is pressed, the actuator will start moving, and once the button is released, the actuator will stop immediately.

Buttons and operation:

(Take HD hand control as an example)

  1. Actuator #1 extends
  2. Actuator #1 retracts
  3. Actuator #2 extends
  4. Actuator #2 retracts
  5. Actuator #3 extends
  6. Actuator #3 retracts
  7. Actuator #4 extends
  8. Actuator #4 retracts

MOTECK-CB4M-Control-Box-fig (3)

Installation & Operation for CB4M-B & CB4M-S

Precautions Before Installation

For safety reasons during initial installation, the entire set of products, including the actuator, must complete the electrical connection and perform the “stroke learning” function before the actuator can be mechanically installed on the user’s equipment

Learning and Operating Guide

For CB4M-B (Take DP11 hand control as an example)

  1. For first time use, it’s required to proceed with the learning process first. All actuators must be connected to the control box according to the model of CB4M-B. If any one is not connected properly, learning and synchronized actions will not be possible.
  2. PressMOTECK-CB4M-Control-Box-fig (4) andMOTECK-CB4M-Control-Box-fig (5) buttons at the same time until the actuators start to move, and start automatic learning. The actuator will automatically move to the lowest position, move to the highest position, and then return to the lowest position to complete automatic learning. Once it’s finished, the system is ready for mechanical installation or normal operationMOTECK-CB4M-Control-Box-fig (6)

For CB4M-S (Take DKP3 hand control as an example)

  1. When CB4M-S and DKP3 are connected and power on at the first time, the display of DKP3 flashes “SEt”. Only learing procedure can be excuted now. All four actuators must be connected to the CB4M-S control box. If any one is not connected properly, learning and synchronized actions will not be possible.
  2. Hold buttons MOTECK-CB4M-Control-Box-fig (8)and MOTECK-CB4M-Control-Box-fig (7)together for 2 seconds, the display flashes “SEt” and the 4 actuators start to run full stroke, so that the program can automatically determine the positions of upper and lower limits. That is, the actuators will all retract to the bottom and extend to the end position, then retract to the bottom position again. After the learning procedure is finished, the display shows a static sign of “000”. Then the actuators are ready to be mechanically installed to user’s device.
  3. General Operation
    • Press and hold button,MOTECK-CB4M-Control-Box-fig (7) and the table will move up to the upper limit position 012.
    • Press and hold button,MOTECK-CB4M-Control-Box-fig 14 the table will move down to the bottom position 000.
    • Standby mode: The display will be off automatically if no button is pressed in 20 seconds.
  4. Memory Function
    • Adjust table as mentioned in paragraph ‘General Operation’ to the height desired. Hold the buttonMOTECK-CB4M-Control-Box-fig (8)for 2 seconds until screen flashes. Followed by pressing buttonMOTECK-CB4M-Control-Box-fig (9), then screen will show “001”; Release the button and the height number will be shown on screen and memorized as position 1.
    • It’s the same way to memorize positions 2, 3, and 4 as position 1.
    • While the screen flashes after holding the button MOTECK-CB4M-Control-Box-fig (8)for 2 seconds, if there is no buttonMOTECK-CB4M-Control-Box-fig (9) ~ MOTECK-CB4M-Control-Box-fig (12)pressed within 10 seconds, the screen will stop flashing and leaving the memory mode.
    • After the memory positions were set, by pressing and holding each buttonMOTECK-CB4M-Control-Box-fig (9) ,MOTECK-CB4M-Control-Box-fig (10) ,MOTECK-CB4M-Control-Box-fig (11) or MOTECK-CB4M-Control-Box-fig (12), table will move toward the memorized position accordingly. But the table will stop immediately once the button is released during the operationMOTECK-CB4M-Control-Box-fig (13)

Others about the Learning Function

  • After completing the mechanical installation on user’s device, please perform the learning function again to learn on the device. However, the unit has to learn again if any one actuator is exchangedor the whole set is moved to drive another table or device.
  • In case of any emergency, pressing any buttons or unplugging the panel can stop actuators from learning the procedure immediately.
  • The unit will memorize the full stroke of the application after finishing the learning procedure. If the power is cut off and reconnected, you can operate it directly without having to “Learn” it again.

Displayed Messages (for CB4M-S only)

Over load protection

The actuators stop moving automatically and panel display will show “E01” when table is loaded over weight. Please release button and reduce some weight of the load. Then press it again to continue operating. Display will show current position of movement.

Reset alignment

When the display is flashing “000”, press and holdMOTECK-CB4M-Control-Box-fig 14 to make table move down to the bottom position for alignment reset. It means reset is finished when display turns to a static sign of “000”, and

For more information about the Hand control operation guide, please refer to the corresponding product data sheet, which can be downloaded from the MOTECK website

Terms of Use

The user is responsible for the suitability of MOTECK products, and the products listed on the MOTECK website are subject to change without notice. MOTECK reserves the right to terminate sales or delete any products displayed on the website or listed in its catalog.

Documents / Resources

MOTECK CB4M Control Box [pdf] Instructions
CB4M, CB4M-B, CB4M-S, CB4M Control Box, CB4M, Control Box, Box

References

Leave a comment

Your email address will not be published. Required fields are marked *