This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your VEVOR 4000PSI (3-Stage) PCP Hand Pump. Please read this manual thoroughly before initial use and retain it for future reference.
The VEVOR PCP Hand Pump is a versatile high-pressure manual pump designed for various inflation needs. It features a 3-stage compression system for efficient air delivery, an integrated oil-water separator filter for dry air, and a durable stainless steel construction. Equipped with a precise pressure gauge, it allows for accurate pressure monitoring during use.

Image: VEVOR PCP Hand Pump in an outdoor setting, highlighting its high-pressure capability and 3-stage дизайн.
Аюулгүй ажиллагааны зааварчилгаа
Always prioritize safety when operating high-pressure equipment. Failure to follow these instructions may result in injury or damage to the product.
- Гарын авлагыг уншина уу: Fully understand all instructions before operating the pump.
- Нүд хамгаалах: Always wear appropriate eye protection when operating the pump.
- Хамгийн их даралт: Do not exceed the maximum rated pressure of the pump (4000PSI / 27.58 MPa) or the maximum pressure of the item being inflated.
- Агааржуулалт: Use the pump in a well-ventilated area.
- Холболтуудыг шалгах: Ensure all connections are secure and free of leaks before and during operation.
- Хүүхэд ба тэжээвэр амьтад: Ашиглалтын явцад хүүхэд, гэрийн тэжээвэр амьтдыг насосноос хол байлга.
- Халуун хэсгүүд: The pump cylinder may become hot during prolonged use. Avoid direct contact.
- Do Not Disassemble Under Pressure: Never attempt to disassemble the pump or its components while it is under pressure.
- Зөв хадгалалт: Store the pump in a dry, cool place, out of reach of unauthorized users.
Хайрцагт юу байна
Бүх эд ангиудыг болгоомжтой задалж, дараах зүйлсийг хүлээн авсан эсэхээ шалгана уу:
- 1 x VEVOR PCP Hand Pump
- 1 x Accessory Kit (includes various adapters, O-rings, filter elements, and tools)
- 1 х хэрэглэгчийн гарын авлага
The accessory kit typically includes:
- Pressure Relief Screw
- Даралт шалгах залгуур
- Various O-Rings (Large, Thin Large, Medium-Large, Medium, Small-Medium, Small)
- High-Pressure Piston Rings
- Булаг
- Sealing Balls
- Filter Replacement Cotton Pads (10 pcs)
- Air Hose with Filter
- Бариул
- Дөрөө
- American Valve Adapter
- Ball Inflation Device
- Бөмбөг зүү
- Kayak Adapter
- 1/8 BSP Female Adapter
- Аллен түлхүүр
- Handle Mounting Screws
- Pedal Mounting Screws

Image: Detailed diagram of the pump with dimensions and a comprehensive list of included accessories.
Тохиргоо
Follow these steps to assemble your PCP hand pump and perform an initial pressure test.
- Бүрэлдэхүүн хэсгүүдийг угсрах: Install the foot pedal onto the base of the pump, secure the handle to the top piston rod, and attach the outlet hose to the pump's connection port. Ensure all connections are tightened securely.
- Initial Unloaded Pumping: Before connecting to any device, run the pump unloaded for approximately 100 cycles. This helps to lubricate internal components and ensure smooth operation.
- Attach Test Plug and Relief Valve: Connect the pressure test plug to the end of the hose. If your model includes a pressure relief valve, ensure it is properly attached and closed.
- Даралтын туршилт хийх: Pump several cycles and observe the pressure gauge. Check all connections for any air leaks. If leaks are detected, tighten connections or inspect O-rings for damage. The pump should hold pressure without significant drop.

Image: Visual guide demonstrating the setup process, including installing components and performing a pressure test.
Ашиглалтын заавар
Follow these steps for safe and efficient inflation:
- Төхөөрөмжид холбогдох: Select the appropriate adapter for your device (e.g., air rifle, tire, ball, kayak) and securely connect it to the pump's hose. Then, connect the adapter to the device you wish to inflate.
- Байршил: Place the pump on a stable, flat surface. Stand with your feet on the foot pedal to stabilize the pump.
- Pumping Technique:
- Pull the handle up to about 90% of its full extension. Keep your arms locked and lean slightly forward.
- Squat down, using your full body weight to keep your arms locked, and press the handle down completely.
- Pull up with your back straight, maintain arm position, and repeat the motion.
- Даралтыг хянах: Continuously monitor the pressure gauge during inflation. Stop pumping once the desired pressure is reached, ensuring not to exceed the maximum pressure rating of your device or the pump.
- Салгах: Once inflation is complete, slowly open the pressure relief valve (if applicable) to release any residual pressure in the hose. Then, carefully disconnect the hose from your device.

Image: Visual instructions on how to properly use the hand pump for efficient inflation.

Зураг: Жишээ ньamples of various items compatible with the VEVOR PCP Hand Pump for inflation.
Засвар үйлчилгээ
Тогтмол засвар үйлчилгээ нь таны насосны урт наслалт, оновчтой ажиллагааг баталгаажуулдаг.
- Oil-Water Separator Filter: The pump features an integrated oil-water separator. Regularly check and replace the filter element to ensure dry air delivery and prevent moisture from entering your device. Replacement filter cotton pads are included in the accessory kit.
- Тосолгоо: Periodically lubricate the pump's piston and O-rings with silicone oil to maintain smooth operation and prevent wear. Refer to the accessory kit for appropriate lubricant if provided.
- Цэвэрлэгээ: Keep the exterior of the pump clean and free from dirt and debris. Use a damp цэвэрлэх зориулалттай даавуу. Химийн хатуу бодис хэрэглэж болохгүй.
- Хадгалах: Store the pump in a clean, dry environment, away from direct sunlight and extreme temperatures.

Image: Instructions for maintaining the built-in oil-water filter, including how to replace the filter element.
Алдааг олж засварлах
Хэрэв та насостой холбоотой асуудалтай тулгарвал дараах нийтлэг асуудал болон шийдлүүдийг үзнэ үү.
| Асуудал | Боломжит шалтгаан | Шийдэл |
|---|---|---|
| Difficulty Pumping / Low Pressure Output | Worn or dry O-rings/seals; Clogged filter; Air leak in connections. | Lubricate O-rings; Replace worn O-rings/seals; Replace filter element; Check and tighten all connections. |
| Агаарын алдагдал | Loose connections; Damaged O-rings/seals; Faulty check valve. | Tighten all hose and adapter connections; Inspect and replace damaged O-rings; Contact VEVOR support if check valve is suspected. |
| Moisture in Air Output | Saturated oil-water separator filter. | Replace the filter element in the oil-water separator. |
| Gauge Not Reading Correctly | Damaged gauge; Air trapped in gauge line. | Perform a pressure test to verify gauge accuracy; If consistently inaccurate, the gauge may need replacement. Contact VEVOR support. |
Үзүүлэлтүүд
| Загварын дугаар | DQT-XB05 |
| Pump Compression Stage | 3 Сtage |
| Хамгийн их даралт | 4000 PSI / 27.58 МПа |
| Ажлын даралт | 0-3600 PSI / 0-24.82 MPa |
| Хоолойн урт | 22 инч / 560 мм |
| Цэвэр жин | 3.64 фунт / 1.65 кг |
| Бүтээгдэхүүний хэмжээ (L x W x H) | 26.5L x 11.5W x 58H см |
| Материал | Зэвэрдэггүй ган |
| Эрчим хүчний эх үүсвэр | Гарын авлага |
| UPC | 197988375821 |
| Гарал үүслийн улс | Хятад |
Баталгаат болон дэмжлэг
Баталгаат мэдээлэл: The product information indicates that the warranty is "Sans objet" (Not applicable). Please refer to your point of purchase or local consumer protection laws for details regarding returns or defects.
Хэрэглэгчийн дэмжлэг: For any questions, technical assistance, or concerns regarding your VEVOR PCP Hand Pump, please contact VEVOR customer service through their official website or the retailer from whom you purchased the product. Have your model number (DQT-XB05) and purchase details ready when contacting support.