GODIYMODULES Standard Edition

GODIYMODULES Digital Display Meter Standard Edition User Manual

Model: Standard Edition

1. ആമുഖം

This manual provides comprehensive instructions for the installation, operation, and maintenance of the GODIYMODULES Digital Display Meter, Standard Edition. This universal analog input display meter is designed to work with various sensors that provide analog output, such as temperature transmitters, frequency converters, motor speed sensors, pressure transducers, and liquid level sensors. Please read this manual thoroughly before operating the device to ensure correct usage and optimal performance.

2. ഉൽപ്പന്നം കഴിഞ്ഞുview

The GODIYMODULES Digital Display Meter is a versatile panel meter capable of displaying actual physical quantities based on analog input signals. It supports both current and voltage inputs, with default adaptations for 0-10V, 2-10V, 0-20mA, and 4-20mA. The meter features a 0.55-inch 4-digit digital tube display for clear readings and intuitive button controls for parameter settings.

ഫ്രണ്ട് view of the GODIYMODULES Digital Display Meter

ചിത്രം 2.1: ഫ്രണ്ട് view of the GODIYMODULES Digital Display Meter, showing the digital display and control buttons.

3 പ്രധാന സവിശേഷതകൾ

  • Universal Analog Input: Compatible with 0-10V, 2-10V, 0-20mA, and 4-20mA signals. Adaptable to other ranges via polarization and gain parameters.
  • വിശാലമായ പവർ സപ്ലൈ ശ്രേണി: DC6~25V for standard and RS485 versions; DC8~25V for relay output version.
  • വൈദ്യുതി സംരക്ഷണം: Features anti-reverse connection and surge protection.
  • Single Analog Input: Supports either voltagഇ അല്ലെങ്കിൽ നിലവിലെ ഇൻപുട്ട്.
  • ഇൻപുട്ട് ഇംപെഡൻസ്: >30kΩ for voltage type, <250Ω for current type.
  • ഡിസ്പ്ലേ മായ്ക്കുക: 0.55 inch, 4-digit digital tube display.
  • Easy Parameter Setting: Built-in buttons for convenient configuration.
  • കോംപാക്റ്റ് ഡിസൈൻ: Mechanical size of 79 x 43 x 25 mm, with an installation opening of 76.5 x 39.5 mm.
  • Optional RS485 Interface: (Available in RS485 version) Supports Modbus-RTU protocol for multi-meter communication.
  • Optional Relay Output: (Available in relay output version) One normally open relay output, load capacity: 3A30VDC/3A250VAC.

4. സജ്ജീകരണം

4.1. മെക്കാനിക്കൽ ഇൻസ്റ്റലേഷൻ

The meter is designed for panel mounting. Ensure the installation opening in your panel matches the specified dimensions.

  • മെക്കാനിക്കൽ വലിപ്പം: 79 mm (Length) x 43 mm (Width) x 25 mm (Depth)
  • ഇൻസ്റ്റലേഷൻ തുറക്കൽ: 76.5 mm (Length) x 39.5 mm (Width)
ടോപ്പ് ആംഗിൾ view of the meter showing buttons and terminal block

ചിത്രം 4.1: ടോപ്പ് ആംഗിൾ view of the meter, illustrating the physical form factor and button layout.

കോണാകൃതിയിലുള്ളത് view of the meter showing buttons and terminal block from another perspective

ചിത്രം 4.2: മറ്റൊരു ആംഗിൾ view of the meter, providing a clearer look at the control buttons and terminal block.

4.2. വയറിംഗ് നിർദ്ദേശങ്ങൾ

Refer to the common wiring diagram for proper connection of power supply and analog input. Ensure the power supply voltagകേടുപാടുകൾ തടയുന്നതിന് e നിർദ്ദിഷ്ട പരിധിക്കുള്ളിലാണ്.

തിരികെ view of the meter with wiring diagram and terminal labels

ചിത്രം 4.3: തിരികെ view of the meter showing the wiring diagram for power, ground, and analog input terminals.

ടെർമിനൽ വിവരണങ്ങൾ:

  • PWR: Positive power supply input (DC6~25V for standard/RS485, DC8~25V for relay version).
  • GND: Ground connection for power supply and analog input.
  • AI: അനലോഗ് വോളിയംtage Input (0-10V, 2-10V).
  • mA: Analog Current Input (0-20mA, 4-20mA).
  • NC: Not Connected.
  • RS485 (R, T, S): For RS485 communication (available in RS485 version only). R indicates data reception, T indicates data transmission, S indicates signal ground.
  • Relay (NO): Normally Open relay output (available in relay output version only).

പ്രധാനപ്പെട്ടത്: The meter supports either voltage input (AI) or current input (mA), but not both simultaneously. Connect your sensor output to the appropriate terminal.

5. പ്രവർത്തന നിർദ്ദേശങ്ങൾ

5.1. Button Functions and Display States

The meter features four buttons for navigation and parameter adjustment: SET, UP (↑), DOWN (↓), and OK. The 4-digit digital display shows the measured value or parameter settings.

ബട്ടൺ പ്രവർത്തനങ്ങൾ:

  • സജ്ജമാക്കുക: Enters parameter setting mode or cycles through parameter groups.
  • UP (↑): Increases value or navigates up in menus.
  • DOWN (↓): Decreases value or navigates down in menus.
  • ശരി: Confirms selection or saves parameter changes.

Digital Tube Display State Transition Diagram:

The meter typically displays the measured value. Pressing the SET button allows entry into the parameter setting menu. Use UP/DOWN to navigate and OK to select/confirm. Pressing SET again will exit the parameter setting mode or move to the next parameter group.

5.2. പാരാമീറ്റർ ക്രമീകരണങ്ങൾ

The meter's functionality is configured through various parameters organized into groups. To enter the parameter setting mode, press the സെറ്റ് ബട്ടൺ. ഉപയോഗിക്കുക UP ഒപ്പം താഴേക്ക് മൂല്യങ്ങൾ ക്രമീകരിക്കാനുള്ള ബട്ടണുകളും OK സ്ഥിരീകരിക്കാൻ. അമർത്തുക സെറ്റ് to move between parameters or exit.

5.2.1. F0-0 Displayed Quantity Collection Parameters

പരാമീറ്റർScope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F0-0Displayed value monitoring: Displays the current collected value. Range: 0-100.0%0.0വായിക്കാൻ മാത്രം
F0-1Display accuracy: The number of decimal places displayed in the collected value. Range: 0-31വായിക്കുക/എഴുതുക
F0-2Show minimum: The minimum value corresponding to "acquisition value" 0%. Range: -9999 to 99990വായിക്കുക/എഴുതുക
F0-3Show maximum: The maximum value corresponding to the "acquisition value" is 100%. Range: -9999 to 99991000വായിക്കുക/എഴുതുക
F0-4Display range: The display range is F0-2 to F0-3. Starting from F0-2.0വായിക്കുക/എഴുതുക

കുറിപ്പ്: The displayed value is a default percentage. You can set your own display range using F0-2 to F0-4.

5.2.2. F1-0 Parameter Group Configuration Parameters

പരാമീറ്റർScope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F1-0Input type selection: 0: 0-10V or 0-20mA (corresponds to 0-100% of the acquisition value). 1: 2-10V or 4-20mA (corresponds to 0-100% of the acquisition value).0വായിക്കുക/എഴുതുക
F1-1Input filter time: The filtering time for the input signal. Range: 0-1000ms.200വായിക്കുക/എഴുതുക
F1-2Input offset: The offset value for the input signal. Range: 0-100.0%0.0വായിക്കുക/എഴുതുക
F1-3Input gain: The gain value for the input signal. Range: 0-100.0%100.0വായിക്കുക/എഴുതുക
F1-4Drop detection threshold: If the input value is not detected, the display will show "----". This parameter sets the threshold for detection. If the input value is less than this threshold, it is considered not detected. Range: 0-100.0% (Starting from V0.10)0.0വായിക്കുക/എഴുതുക

കുറിപ്പ്: By setting the polarization parameter (F1-2) and gain parameter (F1-3), the meter can be adapted to other input ranges within 0-10V or 0-20mA.

5.2.3. F2-0 Parameter Group Relay Output Parameters (for Relay Output Version)

പരാമീറ്റർScope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F2-0Relay output: 0: Normally open, 1: Normally closed.0വായിക്കുക/എഴുതുക
F2-1Condition type: 0: Greater than comparison value 1, 1: Less than comparison value 1, 2: Greater than comparison value 2, 3: Less than comparison value 2.0വായിക്കുക/എഴുതുക
F2-2Comparison value 1: The value used for comparison. Range: 0-100.0%50.0വായിക്കുക/എഴുതുക
F2-3Comparison value 2: The value used for comparison. Range: 0-100.0%0.0വായിക്കുക/എഴുതുക
F2-4Hysteresis interval: The hysteresis value to prevent frequent relay operation. Range: 0-100.0%5.0വായിക്കുക/എഴുതുക
F2-5Relay status when offline: 0: Keep current status, 1: When the offline value is less than the comparison value, the relay is closed, 2: When the offline value is greater than the comparison value, the relay is closed.0വായിക്കുക/എഴുതുക

കുറിപ്പ്: These parameters are only applicable to the version of the meter equipped with a relay output. The Standard Edition may not include this feature.

5.3. RS485 Communication Parameters (for RS485 Version)

This section applies only to the Digital Display Meter with RS485 interface. It uses the standard Modbus-RTU protocol for communication.

Detailed diagram showing parameter settings for F0, F1, F2, and RS485 communication

ചിത്രം 5.1: Comprehensive parameter tables including F0, F1, F2, and RS485 communication settings.

പരാമീറ്റർScope and Descriptionസ്ഥിരസ്ഥിതികൾവായിക്കുക/എഴുതുക
F7-0Local address: The address of the meter in the Modbus network. Range: 1-2471വായിക്കുക/എഴുതുക
F7-1Baud rate: 0: 1200bps, 1: 2400bps, 2: 4800bps, 3: 9600bps, 4: 19200bps, 5: 38400bps.3വായിക്കുക/എഴുതുക
F7-2Data format: 0: 8N1 (8 data bits, 1 stop bit, no parity), 1: 8E1 (8 data bits, 1 stop bit, even parity), 2: 8O1 (8 data bits, 1 stop bit, odd parity), 3: 8N2 (8 data bits, 2 stop bits, no parity).0വായിക്കുക/എഴുതുക
F7-3Response delay: The delay time before the meter responds to a Modbus query. Used to prevent bus collisions in half-duplex communication. Range: 0-100ms.5വായിക്കുക/എഴുതുക
F7-4Communication type: 0: The display table is in the network host mode, 1: The display table is in the network slave mode, 2: The display table through the broadcast mode.0വായിക്കുക/എഴുതുക
F7-5Parameter interval: The interval time for the meter to send parameters. Range: 0-1000ms.100വായിക്കുക/എഴുതുക
F7-6Send recovery time: The time for the meter to send recovery parameters. Range: 0-1000ms.100വായിക്കുക/എഴുതുക
F7-7Software version number: Displays the current software version.1.00വായിക്കാൻ മാത്രം

Modbus-RTU Protocol Details:

The meter supports standard Modbus-RTU protocol. The communication parameters (address, baud rate, data format) must be configured correctly to match the master device. The image also shows a table of Modbus register addresses for various parameters (e.g., F0-0, F0-1, F1-0, etc.) which can be read or written via Modbus commands.

For detailed Modbus register addresses and functions, refer to the provided diagram (Figure 5.1) or the official Modbus communication guide for this device. Example: To read F0-0, use Modbus function code 03 (Read Holding Registers) with the corresponding address.

6. പരിപാലനം

  • വൃത്തിയാക്കൽ: Use a soft, dry cloth to clean the meter's display and casing. അബ്രാസീവ് ക്ലീനറുകളോ ലായകങ്ങളോ ഉപയോഗിക്കരുത്.
  • പരിസ്ഥിതി: Ensure the meter is operated within its specified environmental conditions (temperature, humidity) to prolong its lifespan.
  • കണക്ഷനുകൾ: Periodically check all wiring connections for tightness and ensure they are free from corrosion.
  • കാലിബ്രേഷൻ: If accuracy issues are suspected, refer to the parameter settings for input offset and gain adjustment, or consult a qualified technician for recalibration.

7. പ്രശ്‌നപരിഹാരം

പ്രശ്നംസാധ്യമായ കാരണംപരിഹാരം
മീറ്റർ പവർ ഓൺ ആകുന്നില്ല.വൈദ്യുതി വിതരണം ഇല്ല അല്ലെങ്കിൽ തെറ്റായ വോളിയംtage.Check power connections and ensure voltage is within DC6~25V (or DC8~25V for relay version).
Display shows "----".No analog input signal detected or signal below F1-4 threshold.Verify sensor connection and output. Check F1-4 (Drop detection threshold) setting.
തെറ്റായ വായനകൾ.Incorrect input type (F1-0), offset (F1-2), or gain (F1-3) settings. Sensor malfunction.Review F1-0, F1-2, F1-3 parameters. Check sensor calibration and output.
RS485 ആശയവിനിമയ പരാജയം.Incorrect RS485 parameters (F7-0 to F7-4). Wiring issues.Verify F7-0 (Local address), F7-1 (Baud rate), F7-2 (Data format) match the master device. Check RS485 wiring (R, T, S).

8 സ്പെസിഫിക്കേഷനുകൾ

ബ്രാൻഡ്ഗോഡിമോഡ്യൂൾസ്
മോഡൽസ്റ്റാൻഡേർഡ് എഡിഷൻ
ഇൻപുട്ട് സിഗ്നൽ തരങ്ങൾവാല്യംtage (0-10V, 2-10V), Current (0-20mA, 4-20mA)
Power Supply (Standard/RS485)DC6~25V
Power Consumption (Standard/RS485)24V/40mA
Power Supply (Relay Output Version)DC8~25V
Power Consumption (Relay Output Version)24V/50mA
Input Impedance (Voltage Type)>30kΩ
Input Impedance (Current Type)<250Ω
പ്രദർശിപ്പിക്കുക0.55 inch, 4-digit digital tube
മെക്കാനിക്കൽ വലിപ്പം79 x 43 x 25 മിമി
ഇൻസ്റ്റലേഷൻ തുറക്കൽ76.5 x 39.5 മി.മീ
ഭാരം50 ഗ്രാം
RS485 Protocol (Optional)മോഡ്ബസ്-ആർ.ടി.യു
റിലേ ഔട്ട്പുട്ട് (ഓപ്ഷണൽ)1 Normally Open, 3A30VDC/3A250VAC

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.