Mitsubishi Split-Type Air Conditioners
SAFETY PRECAUTIONS
Meanings of symbols displayed on indoor unit and/or outdoor unit
![]() |
WARNING |
This unit uses a flammable refrigerant. If refrigerant leaks and comes in contact with fi re or heating part, it will create harmful gas and there is risk of fi re. |
![]() |
Read the OPERATING INSTRUCTIONS carefully before operation. | |
![]() |
Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation. | |
![]() |
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like. |
- Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use.
- Since the cautionary items shown here are important for safety, be sure to observe them.
- After reading this manual, keep it together with the installation manual in a handy place for easy reference.
- Be sure to receive a guarantee card from your dealer and check that the purchased data and shop name, etc. are entered correctly
Marks and their meanings
![]() |
Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability |
![]() |
Incorrect handling could cause serious hazard depending on the conditions. |
Meanings of symbols used in this manual
![]() |
Be sure not to do. |
![]() |
Be sure to follow the instruction |
![]() |
Never insert your finger or stick, etc. |
![]() |
Never step onto the indoor/outdoor unit and do not put anything on them. |
![]() |
Danger of electric shock. Be careful |
![]() |
Be sure to disconnect the power supply plug from the power outlet |
![]() |
Be sure to shut off the power. |
![]() |
Risk of fire. |
![]() |
Never touch with wet hand. |
![]() |
Never splash water on the unit. |
|
|
![]() |
The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
|
When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant (R32) enters the refrigerant circuit.
|
|
Do not bundle, pull, damage, or modify the power cord, and do not apply heat or place heavy objects on it.
|
|
The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
|
|
When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerant (R32) enters the refrigerant circuit.
|
|
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. | |
Children should be supervised to ensure that they do not play with the appliance. | |
![]() |
Do not insert your finger, a stick, or other objects into the air inlet or outlet.
|
![]() |
In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF.
|
![]() |
When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. If any refrigerant leakage is found, stop operations and ventilate the room well and consult your dealer immediately. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
|
The user should never attempt to wash the inside of the indoor unit. Should the inside of the unit require cleaning, contact your dealer.
|
|
The indoor unit must be installed in rooms which exceed the floor space specified. Please consult your dealer.
|
|
When the indoor unit is connected to the multi type outdoor unit of R32 refrigerant, please consult your dealer about the floor space specified. | |
![]() |
This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. |
Do not touch the air purifying device from the top of the indoor unit during operation. | |
|
|
![]() |
Do not touch the air inlet or the aluminum fi ns of the indoor/outdoor unit.
|
Do not use insecticides or flammable sprays on the unit.
|
|
Do not expose pets or houseplants to direct airflow.
|
|
Do not place other electric appliances or furniture under the indoor/ outdoor unit.
|
|
Do not leave the unit on a damaged installation stand.
|
|
Do not step on an unstable bench to operate or clean the unit.
|
|
Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
|
|
Do not expose your body directly to cool air for a prolonged length of time.
|
|
Do not pull the power cord.
|
|
Do not charge or disassemble the batteries, and do not throw them into a fire.
|
|
Do not operate the unit for more than 4 hours at high humidity (80% RH or more) and/or with windows or outside door left open.
|
|
Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects.
|
|
Do not expose combustion appliances to direct airflow.
|
|
Never put batteries in your mouth for any reason to avoid accidental ingestion.
|
|
![]() |
Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.
|
When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.
|
|
Replace all batteries of the remote controller with new ones of the same type.
|
|
If the battery fluid comes in contact with your skin or clothes, wash them thoroughly with clean water.
|
|
Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance.
|
|
Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike.
|
|
After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning.
|
|
![]() |
Do not operate switches with wet hands.
|
Do not clean the air conditioner with water or place an object that contains water, such as a flower vase, on it.
• This may cause fi re or electric shock. |
|
![]() |
Do not step on or place any object on the outdoor unit.
|
For installation
|
|
![]() |
Consult your dealer for installing the air conditioner.
|
Provide a dedicated power supply for the air conditioner.
|
|
Do not install the unit where flammable gas could leak.
|
|
![]() |
Earth the unit correctly.
|
|
|
![]() |
Install an earth leakage breaker depending on the installation location of the air conditioner (such as highly humid areas).
|
Ensure that the drain water is properly drained.
|
In case of an abnormal condition Immediately stop operating the air conditioner and consult your dealer. |
For Wi-Fi interface
|
|
![]() |
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. |
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. | |
Do not use the Wi-Fi interface nearby the medical electrical equipment or people who have a medical device such as a cardiac pacemaker or an implantable cardioverter-defibrillator.
|
|
Do not install the Wi-Fi interface nearby the automatic control devices such as automatic doors or fi re alarms.
|
|
![]() |
Do not touch the Wi-Fi interface with wet hands.
|
![]() |
Do not splash water on the Wi-Fi interface or use it in a bathroom.
|
![]() |
When the Wi-Fi interface is dropped, or the holder or cable is damaged, disconnect the power supply plug or turn the breaker OFF.
|
|
|
![]() |
Do not step on unstable stepstool to set up or clean the Wi-Fi interface.
|
Do not use the Wi-Fi interface nearby other wireless devices, microwaves, cordless phones, or facsimiles.
|
NAME OF EACH PART
Indoor unit
Outdoor unit
Indoor unit Remote controller
Remote controller holder![]()
|
Only use the remote controller provided with the unit.
Do not use other remote controllers.
If 2 or more indoor units are installed in proximity to one another, an indoor unit that is not intended to be operated may respond to the remote controller.
PREPARATION BEFORE OPERATION
Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on.
Installing the remote controller batteries
Note:
- Make sure the polarity of the batteries is correct.
- Do not use manganese batteries and leaking batteries. The remote controller could malfunction.
- Do not use rechargeable batteries.
- The battery replacement indicator lights up when the battery is running low.
In about 7 days after the indicator starts lights up, the remote controller stops working. - Replace all batteries with new ones of the same type.
- Batteries can be used for approximately 1 year. However, batteries with expired shelf lives last shorter.
- Press RESET gently using a thin instrument.
If the RESET button is not pressed, the remote controller may not operate correctly.
Setting current time
Note:
- Press CLOCK gently using a thin instrument.
Note:
How to set remote controller exclusively for a particular indoor unit
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
To operate the indoor units individually with each remote controller, assign a number to each remote controller according to the number of the indoor unit.
This setting can be set only when all the following conditions are met:
- The remote controller is powered OFF.
- Hold down
button on the remote controller for 2 seconds to enter the pairing mode.
- Press
button again and assign a number to each remote controller.
Each press ofbutton advances the number in the following order: 1 → 2 → 3 → 4.
- Press
button to complete the pairing setting.
After you turn the breaker ON, the remote controller that first sends a signal to an indoor unit will be regarded as the remote controller for the indoor unit.
Once they are set, the indoor unit will only receive the signal from the assigned remote controller afterwards.
Setting the installation position
Be sure to set the remote controller in accordance with the installed position of the indoor unit.
Installation position:
Left: Distance to objects (wall, cabinet, etc.) is less than 50 cm to the left
Center: Distance to objects (wall, cabinet, etc.) is more than 50 cm to the left and right
Right: Distance to objects (wall, cabinet, etc.) is less than 50 cm to the right
- Hold down
on the remote controller for 2 seconds to enter the position setting mode.
- Select the target installation position by pressing
.
(Each press of thedisplays the positions in order:)
- Press
to complete the position setting.
Note:
The installation position can be set only when all the following conditions are met:
- The remote controller is powered off.
- Weekly timer is not set.
- Weekly timer is not being edited.
I-SEE OPERATION
In the i-see control mode, the room temperature is controlled based on the sensible temperature.
- Press
during COOL, DRY, HEAT and AUTO mode to activate the i-see control mode.
• Press gently using a thin instrument.
•lights. (Operation display section)
• The default setting is “active”.
- Press
several times to cancel the i-see control mode.
Note:
Any person at the following places cannot be detected:
- Along the wall on which the air conditioner is installed
- Directly under the air conditioner
- Where any obstacle, such as furniture, is between the person and the air
conditioner
A person may not be detected in the following situations:
- Room temperature is high.
- A person wears heavy clothes and his/her skin is not exposed.
- A heating element of which temperature changes significantly is present.
- Some heat sources, such as a small child or pet, may not be sensed.
- A heat source and the air conditioner are more than 6 m apart.
- A heat source does not move for a long time.
Do not touch the i-see sensor. This may cause malfunction of the i-see sensor. The intermittent operating sound is a normal sound produced when the i-see sensor is moving from side to side.
Check down below “Absence Detection” for and
.
SELECTING OPERATION MODES
- Press
to start the operation.
- Press
to select operation mode. Each press changes mode in the following order:
- Press
or
to set the temperature.
Each press raises or lowers the temperature by 1°C. - Press
to stop the operation.
AUTO mode (Auto change over)
The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is about 2°C away from the set temperature for more than 15 minutes.
Note:
Auto Mode is not recommended if this indoor unit is connected to a MXZ
type outdoor unit. When several indoor units are operated simultaneously,
the unit may not be able to switch operation mode between COOL and
HEAT. In this case, the indoor unit becomes standby mode (Refer to table
of Operation indicator lamp).
COOL mode
Enjoy cool air at your desired temperature.
Note:
Do not operate COOL mode at very low outside temperatures (less than -10°C). Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
HEAT mode
Enjoy warm air at your desired temperature.
FAN mode
Circulate the air in your room
Note:
After COOL/DRY mode operation, it is recommended to operate in the FAN mode to dry inside the indoor unit.
Note:
Multi system operation
Two or more indoor units can be operated by one outdoor unit. When several
indoor units are operated simultaneously, cooling/dry/fan and heating operations cannot be done at the same time. When COOL/DRY/FAN is selected with one unit and HEAT with another or vice versa, the unit selected last goes into standby mode.
Operation indicator lamp
The operation indicator lamp shows the operation state of the unit
Indication |
Operation state |
![]() |
Standby mode (only during multi system operation) |
Lit
Blinking
FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT
Fan speed
Press to select fan speed. Each press changes fan speed in the following order:
- Two short beeps are heard from the indoor unit when set to AUTO.
- Use higher fan speed to cool/heat the room quicker. It is recommended to lower the fan speed once the room is cool/warm.
- Use lower fan speed for quiet operation.
Note:
Multi system operation
When several indoor units are operated simultaneously by one outdoor unit for heating operation, the temperature of the airflow may be low. In this case, it is recommended to set the fan speed to AUTO.
Up-down Airflow direction
Press to select airflow direction. Each press changes airflow direction in the following order:
(AUTO)……… The vane is set to the most efficient airflow direction. COOL/ DRY/FAN: horizontal position. HEAT: position (4).
(Manual) ……. For efficient air conditioning, select the upper position for COOL/DRY, and the lower position for HEAT. If the lower position is selected during COOL/DRY, the vane automatically moves to the upward position (1) after 0.5 to 1 hour to prevent any condensation from dripping.
(Swing) ……… The vane moves up and down intermittently.
- Two short beeps are heard from the indoor unit when set to AUTO.
- Always use the remote controller when changing the direction of airflow.
Moving the horizontal vanes with your hands causes them to malfunction. - When the breaker is turned on, the horizontal vanes’ position will be reset in about a minute, then the operation will start. The same is true in the emergency cooling operation.
- When the horizontal vanes seem to be in an abnormal position, Check down below.
- The right and left horizontal vanes set to the same level may not align perfectly
Left-right Airflow direction
Press to select airflow direction. Each press changes airflow direction in the following order:
AIRFLOW CONTROL MODE
Airflow Control mode offers air conditioning according to a location of an occupant in a room detected by i-see Sensor.
- Press
during COOL, DRY, HEAT or AUTO mode to activate the AIRFLOW CONTROL mode. This mode is only available when the i-see control mode is effective.
- Each press of
changes AIRFLOW CONTROL in the following order:
(INDIRECT) : An occupant will be less exposed to direct airflow.
(DIRECT) : Mainly the vicinity of an occupant will be air-conditioned.
(EVEN) : The unit learns the area where an occupant spend most of the time, and evens out the temperature of that area.
• Horizontal and vertical airflow directions will be automatically selected.
• When more than a couple of people are in a room, the AIRFLOW CONTROL mode may work less effectively.
• If you still feel uncomfortable with the air direction determined by the INDIRECT mode, adjust the air direction manually. Check above
- Cancelling the i-see control mode automatically cancels the AIRFLOW CONTROL mode.
• The AIRFLOW CONTROL mode is also cancelled when the VANE or
WIDE VANE buttons is pressed.
ABSENCE DETECTION
This function automatically changes the operation to No occupancy energy-saving mode or No occupancy Auto-OFF mode when nobody is in the room.
- To activate this No occupancy energy-saving mode, press
until
appears on the operation display of the remote controller.
- To activate this No occupancy Auto-OFF mode, press
until
appears on the operation display of the remote controller.
- Press again to cancel the ABSENCE DETECTION.
- Even if the unit is turned OFF due to No occupancy Auto-OFF mode, the display of the remote controller remains to indicate the unit is in operation. Press
then press
again to restart operation.
- When OFF timer is set, a priority is given to OFF timer.
- No occupancy energy saving mode or No occupancy Auto-OFF mode are not available during POWERFUL operation.
- The unit will not be turned off if no one is detected during normal operation mode, even though No occupancy Auto-OFF mode is activated.
I-SAVE OPERATION
A simplified set back function enables to recall the preferred (preset) setting with a single push of the button. Press the button again and you can go back to the previous setting in an instance.
- Press
during COOL, ECONO COOL, HEAT mode and NIGHT MODE operation to select i-save mode.
- Set the temperature, fan speed, and airflow direction.
• The same setting is selected from the next time by simply pressing
• Two settings can be saved. (One for COOL/ECONO COOL, one for HEAT)
• Select the appropriate temperature, fan speed, and airflow direction according to your room. - Press
again to cancel i-save operation.
• i-save operation also is cancelled when the MODE or POWERFUL button is pressed.
Note:
Example of use:
- Low energy mode
Set the temperature 2°C to 3°C warmer in COOL and cooler in HEAT mode. This setting is suitable for unoccupied room, and while you are sleeping. - Saving frequently used settings
Save your preferred setting for COOL, ECONO COOL, HEAT mode and NIGHT MODE operation. This enables you to select your preferred setting with a single push of the button.
ECONO COOL OPERATION
Swing airflow (change of airflow) makes you feel cooler than stationary airflow.
The set temperature and the airflow direction are automatically changed by the microprocessor. It is possible to perform cooling operation with keeping comfort. As a result energy can be saved.
- Press
during COOL mode to start ECONO COOL operation.
The unit performs swing operation vertically in various cycles according to the temperature airflow. - Press
again to cancel ECONO COOL operation.
• ECONO COOL operation is also cancelled when the VANE or POWERFUL button is pressed.
NIGHT MODE OPERATION
NIGHT MODE operation changes the brightness of the operation indicator, disables the beep sound and limits the noise level of the outdoor unit.
- Press
during operation to activate NIGHT MODE operation.
• The operation indicator lamp dims.
• The beep sound will be disabled except that emitted when the operation is started or stopped.
• Noise level of the outdoor unit will be lower than that mentioned in SPECIFICATIONS. - Press
again to cancel NIGHT MODE operation.
Note:
- Noise level of the outdoor unit may not change after start-up of the unit, during the protection operation, or depending on other operating conditions.
- The fan speed of the indoor unit will not change.
- The operation indicator lamp will be hard to be seen in a bright room.
- Operating POWERFUL operation during NIGHT MODE operation will increase the noise level of the outdoor unit.
- Noise level of the outdoor unit will not decrease during Multi system operation.
AIR PURIFYING OPERATION
In the AIR PURIFYING operation, the indoor unit built-in device reduces airborne fungi, viruses, mold, and allergens.
- Press
to start AIR PURIFYING operation.
• AIR PURIFYING lamp turns on. (Display section) - Press
again to cancel AIR PURIFYING operation.
• AIR PURIFYING lamp turns off. (Display section)
Note:
- Never touch the air purifying device during operation. Although the air purifying device is safety-conscious design, touching this device could be the cause of trouble as this device discharge high voltage electricity.
- A “hissing” sound may be heard during the air purifying operation. This sound is produced when plasma is being discharged. This is not a malfunction.
- Air purifying lamp does not turn on if the front panel is not closed completely.
POWERFUL OPERATION
- Press
during COOL or HEAT (Check above) to start POWERFUL operation.
Fan speed : Exclusive speed for POWERFUL mode
Horizontal vane : Set position, or downward airflow position during AUTO setting
• Temperature cannot be set during POWERFUL operation. - Press
again to cancel POWERFUL operation.
• POWERFUL operation is also cancelled automatically in 15 minutes, or when the OFF/ON, FAN, ECONO COOL or i-save button is pressed.
TIMER OPERATION (ON/OFF TIMER)
- Press
or
during operation to set the timer.
(ON timer) : The unit turns ON at the set time.
(OFF timer) : The unit turns OFF at the set time.
*ON or
OFF blinks.
* Make sure that the current time and day are set correctly. (Check above) - Press
(Increase) and
(Decrease) to set the time of timer.
Each press increases or decreases the set time by 10 minutes.
• Set the timer while or is blinking. - Press or again to cancel timer.
Note:
- ON and OFF timers can be set together.
mark indicates the order of timer operations.
- If power failure occurs while ON/OFF timer is set, (Check down below) “Auto restart function”.
WEEKLY TIMER OPERATION
- A maximum of 4 ON or OFF timers can be set for individual days of the week.
- A maximum of 28 ON or OFF timers can be set for a week
E.g.: Runs at 24°C from waking up to leaving home, and runs at 27°C from getting home to going to bed on weekdays. Runs at 27°C from waking up late to going bed early on weekends![]() |
Note:
The simple ON/OFF timer setting is available while the weekly timer is on. In this case, the ON/OFF timer has priority over the weekly timer; the weekly timer operation will start again after the simple ON/OFF timer is complete.
Setting the weekly timer
* Make sure that the current time and day are set correctly.
- Press to enter the weekly timer setting mode.
*
blinks.
- Press and to select setting day and number.
- Press
,
and
to set ON/OFF, time, and temperature.
* Hold down the button to change the time quickly.
Pressand
to continue setting the timer for other days and/or numbers.
- Press to complete and transmit the weekly timer setting.
Note:
• Pressto transmit the setting information of weekly timer to the indoor unit. Point the remote controller toward the indoor unit for 3 seconds.
• When setting the timer for more than one day of the week or one number,does not have to be pressed per each setting. Press
once after all the settings are complete. All the weekly timer settings will be saved.
• Pressto enter the weekly timer setting mode, and press and hold
for 5 seconds to erase all weekly timer settings. Point the remote controller toward the indoor unit.
- Press
to turn the weekly timer ON. (
lights.)
* When the weekly timer is ON, the day of the week whose timer setting is complete, will light.
Pressto turn the weekly timer ON. (
lights.)
* When the weekly timer is ON, the day of the week whose timer setting
is complete, will light.
Note:
The saved settings will not be cleared when the weekly timer is turned OFF.
Checking weekly timer setting
- Press
to enter the weekly timer setting mode. * blinks.
- Press
or
to view the setting of the particular day or number.
- Press
to exit the weekly timer setting.
Note:
When all days of the week are selected to view the settings and a different setting is included among them, will be displayed.
CLEANING
Instructions:
- Switch off the power supply or turn off the breaker before cleaning.
- Be careful not to touch the metal parts with your hands.
- Do not use benzine, thinner, polishing powder, or insecticide.
- Use only diluted mild detergents.
- Do not use a scrubbing brush, a hard sponge, or the like
- Do not soak or rinse the horizontal vane.
- Do not use water hotter than 50°C.
- Do not expose parts to direct sunlight, heat, or fi re to dry.
- Do not apply excessive force on the fan as it may cause cracks or breakage.
Wi-Fi INTERFACE SETTING UP
This Wi-Fi interface, communicates the status information and controls the commands from the the server by connecting to an indoor unit.
Wi-Fi interface introduction
No | Item | Description |
1 | MODE Button | Selects modes. |
2 | RESET Button | Resets the system and ALL settings. |
3 | ERR LED (Orange) | Shows the network error state. |
4 | NET LED (Green) | Shows the network state. |
5 | MODE LED (Orange) | Shows the Access Point Mode state. |
6 | UNIT LED (Green) | Shows the indoor unit state. |
(1) MODE Button
WPS-Push
- Hold down the MODE Button for 2 seconds to start WPS-Push Pairing.
- When WPS-Push is enabled on the Wi-Fi interface, the MODE LED starts flashing orange (every second) and the pairing can be completed by enabling WPS-Push on the Router.
Access Point Mode
- Hold down the MODE Button for 7 seconds to start Access Point Mode.
- When Access Point Mode is enabled on the Wi-Fi interface, the MODE LED starts flashing orange (every 5 seconds).
- To cancel Access Point Mode, hold down the MODE Button for 7 seconds again and ensure that the MODE LED is no longer flashing.
WPS-PIN
- Hold down the MODE Button for 15 seconds to start WPS-PIN Pairing.
- When WPS-PIN is enabled on the Wi-Fi interface, MODE LED starts flashing orange (every 0.5 seconds) and the pairing can be completed by enabling WPS-PIN on the Router.
- Before using WPS-PIN, the PIN code of the Wi-Fi interface needs to be set on the Router.
2) RESET Button
- Hold down the RESET Button for 2 seconds to reboot the system.
- Hold down the RESET Button for 15 seconds to initialize the Wi-Fi interface to the factory default.
Note:
When the Wi-Fi interface is reset to the factory default, ALL the configuration information will be lost. Take great care in implementing this operation.
Information for users
The following steps explain how to connect the Wi-Fi interface to a Router.
KEY (LED LIGHTS): :ON
:OFF
:Flashing
1. Ensure the Wi-Fi interface is connected correctly as per the previous section, ‘Connecting the Wi-Fi interface’.
UNIT LED should be flashing green only.
2. Download and install Wi-Fi Control App to your compatible Apple or Android smartphone/tablet (search term: Mitsubishi Wi-Fi Control).
THERE ARE TWO OPTIONS OF CONNECTING
Option 1 – Access Point Mode Pairing
3. Activate Access Point Mode on your Wi-Fi interface by using a small object to press and hold the MODE Button for 7 seconds.
4. When Access Point Mode is enabled on the Wi-Fi interface, MODE LED starts flashing orange (every 5 seconds).
5. Check the label on the back of the interface for the SSID.
Open the Wi-Fi networks screen on your smartphone/ tablet and connect to the network with the same name as the SSID. The network password, labelled KEY, is just under the SSID on the interface.
You will now be connected to this Wi-Fi interface
6. Open Wi-Fi Control App and follow the ‘How to Setup’ instructions in the ‘Setup Wi-Fi interface’ section.
If the app does not go to this section, you are not connected to the Wi-Fi interface’s Access Point; please start process again.
You can either select your available Wi-Fi Network, or manually configure a Wi-Fi Network.
7. Once completed, the MAC and ID will be filled in ‘Add new unit’. Select ‘Add’ and then control your heat pump via Wi-Fi.
Option 2 – WPS-Push Pairing
- Please Note: The WPS and Router reset buttons may be similar on some Routers.
- Please exercise caution as resetting your Router will erase network configuration.
3. Check Wi-Fi and WPS are enabled on your Router. The connection procedure varies depending on your Router – refer to your Router’s manual for more information.
4. Activate WPS Mode on your Router. This will be enabled for a set period allowing approximately 2 minutes to complete the next step. To do so, please refer to your Router’s manual.
5. Activate WPS on your Wi-Fi interface by using a small object to press and hold the MODE Button for 2 seconds.
6. When WPS-Push is enabled on the Wi-Fi interface, MODE LED starts flashing orange (every second).
7. When pairing process is completed on the Wi-Fi interface, the NET LED lights up solid green for 5 seconds.
8. If ERR LED lights up orange for 5 seconds at any stage, there may be a problem; please start process again.
9. Open Wi-Fi Control App. Enter MAC and ID into ‘Add new unit’ and select ‘Add’.
10. Once completed, control your heat pump via Wi-Fi.
LED Pattern
:ON
:OFF
:Flashing
● Software initialising | ||||
Description |
ERR (Orange) |
NET (Green) | MODE (Orange) |
UNIT (Green) |
Firmware updating | ![]() |
![]() |
![]() |
|
Firmware downloading | ![]() |
(every second) | (every second) | ![]() |
Reset to the factory default | ![]() |
![]() |
![]() |
![]() |
● Wireless setting | ||||
Description |
ERR (Orange) |
NET (Green) | MODE (Orange) |
UNIT (Green) |
Access Point Mode activated | ![]() |
![]() |
![]() (every 5 sec) |
|
WPS-PUSH Mode activated | ![]() |
![]() |
![]() (every second) |
![]() |
WPS-PIN Mode activated | ![]() |
![]() |
![]() (every 0.5 sec) |
![]() |
Pairing process via WPS completed | ![]() |
![]() (5 sec) |
![]() |
![]() |
Pairing process via WPS failed |
|
![]() |
![]() |
![]() |
● Connection to server in progress | ||||
Description |
ERR (Orange) |
NET (Green) | MODE (Orange) |
UNIT (Green) |
Communicating with server, and starting up indoor unit communication |
|
|
![]() |
![]() |
Communicating with server, and communicating with indoor unit |
|
|
|
|
● Normal operation | ||||
Description |
ERR (Orange) |
NET (Green) | MODE (Orange) |
UNIT (Green) |
Communicating with server, and communicating with indoor unit |
|
|
|
|
(*1) Details of flash pattern
- Every 0.5 sec: Searching for server.
- Every second: Registering the information of the Wi-Fi interface to server.
Wi-Fi INTERFACE SETTING UP
Troubleshooting
:ON
:OFF
:Flashing
Description | ERR (Orange) | NET (Green) | MODE (Orange) | UNIT (Green) |
Connection to server established, and connection to indoor unit failed | ![]() |
![]() |
![]() |
![]() |
Connection to Router failed, and connection to indoor unit established | ![]() |
|
![]() |
![]() |
Connection to Router failed, and starting up indoor unit connection | ![]() |
|
![]() |
![]() |
Connection to Router failed, and connection to indoor unit failed | ![]() |
![]() (*3) |
![]() |
![]() |
Connection to server failed, and connection to indoor unit established |
|
![]() |
![]() |
![]() |
Connection to server failed, and starting up indoor unit connection |
|
![]() |
![]() |
![]() |
Connection to server failed, and connection to indoor unit failed |
|
![]() |
![]() |
![]() |
(*2) Details of flash pattern
- Every 0.5 sec: IP address setting is invalid. Check DHCP Settings of the
Router, or check IP address settings of the Wi-Fi interface. If both settings
are correct but still the problem persists, push RESET Button for more than 15 seconds to retry the pairing. - Every second: DNS setting is invalid. Check DNS Settings of the Router,
or check DNS address settings of the Wi-Fi interface. If both settings are correct but still the problem persists, push RESET Button for more than 15 seconds to retry the pairing. - Twice every 5 sec: Not connected to server. Check if the Router is connected to the internet.
- Once every 5 sec: Not communicating with server properly. Push RESET Button for 2 seconds.
(*3) Details when NET LED is OFF
The Wi-Fi interface failed to connect to the Router. Check the following, and pair the Wi-Fi interface.
- Make sure that the communication distance is not too far between the Wi-Fi interface and the Router.
- Make sure 2.4GHz is enabled on dual band Routers.
- Make sure that the Router uses WPA2-PSK(AES) encryption.
- Make sure that the number of connected devices to the Router does not exceed the limit.
- Make sure that WPS is working on the Router.
- Make sure that the Router is compatible with the Wi-Fi interface.
- If Static IP has been set – make sure it is correct as per Router network settings.
If a problem regarding connecting your Router and the Wi-Fi interface persists, please contact your local Mitsubishi Electric office, as listed on the back of this guide. A list of compatible Routers is also available.
Note:
- Ensure that the Router supports the WPA2-AES encryption setting before starting the Wi-Fi interface setup.
- The End user should read and accept the terms and conditions of the Wi-Fi service before using this Wi-Fi interface.
- To complete connection of this Wi-Fi interface to the Wi-Fi service, the Router may be required.
- This Wi-Fi interface will not commence transmission of any operational data
from the system until the End user registers and accepts the terms and conditions of the Wi-Fi service. - This Wi-Fi interface should not be installed and connected to any Mitsubishi Electric system which is to provide application critical cooling or heating.
- Please write down the information regarding the Wi-Fi interface setting on the last page of this manual, when you set up this Wi-Fi interface.
- At the time of relocation or disposal, reset the Wi-Fi interface to the factory default.
Mitsubishi Electric’s Wi-Fi interface is designed for communication to Mitsubishi Electric’s Wi-Fi service. Third party Wi-Fi interfaces cannot connect to Mitsubishi Electric’s Wi-Fi service. Mitsubishi Electric is not responsible for any (i) underperformance of a system or any product; (ii) system or product fault; or (iii) loss or damage to any system or product; which is caused by or arises from connection to and/or use of any third party Wi-Fi interface or any third party Wi-Fi service with Mitsubishi Electric equipment |
For the latest information regarding Wi-Fi Control: New Zealand based enquiries please visit: www.mitsubishi-electric.co.nz/wifi Australian based enquiries please visit: www.mitsubishielectric.com.au/wifi |
Mitsubishi Electric Wi-Fi Heat Pump Control
Register Your Heat Pump(s)
Thank you for choosing a Mitsubishi Electric Heat Pump with Wi-Fi Control.
Once your Wi-Fi interface is installed, either download the app (search term:
Mitsubishi Wi-Fi Control) or visit our website to register your heat pump(s).
Once registered you will be able to control your heat pump with your smartphone, tablet or online account using an internet connection.
(For a list of compatible devices, please visit the Mitsubishi Electric website).
User Manual
A copy of the user manual, terms & conditions and privacy policy can be downloaded at any time from the Mitsubishi Electric website.
Mitsubishi Electric New Zealand
www.mitsubishi-electric.co.nz/wifi
Phone: 0800 639 434
Mitsubishi Electric Australia
www.mitsubishielectric.com.au/wifi
Phone: 1300 728 119
*Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S.
and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries.
*Google Play and the Google Play logo are trademarks of Google Inc.
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
Even if these items are checked, when the unit does not recover from the trouble, stop using the air conditioner and consult your dealer. |
Symptom | Explanation & Check points |
Indoor Unit | |
The unit cannot be operated. |
|
The horizontal vane does not move. |
|
The unit cannot be operated for about 3 minutes when restarted. |
|
Mist is discharged from the air outlet of the indoor unit. |
|
The swing operation of the HORI- ZONTAL VANE is suspended for a while, then restarted. |
|
When SWING is selected in COOL/DRY/FAN mode, the lower horizontal vane does not move. |
|
The airflow direction changes during operation.
The direction of the horizontal vane cannot be adjusted with the remote controller. |
|
The operation stops for about 10 minutes in the heating operation. |
|
The unit starts operation by itself when the main power is turned on, but hasn’t received sign from the remote controller. |
|
The two horizontal vanes touch each other. The horizontal vanes are in an abnormal position. The horizontal vanes do not return to the correct “close position”. | Perform one of the following:
|
In COOL/DRY mode, when the room temperature reaches near the set temperature, the outdoor unit stops, then the indoor unit operates at low speed. |
|
The indoor unit discolors over time. |
|
The operation indicator lamp is dim. The unit does not beep. |
|
Multi system | |
The indoor unit which is not operating becomes warm and a sound, similar to water flowing, is heard from the unit. |
|
When heating operation is selected, operation does not start right away. |
|
Outdoor Unit | |
The fan of the outdoor unit does not rotate even though the com- pressor is running. Even if the fan starts to rotate, it stops soon. |
|
Water leaks from the outdoor unit. |
|
White smoke is discharged from the outdoor unit. |
|
Remote controller | |
The display on the remote controller does not appear or it is dim. The indoor unit does not respond to the remote control signal. |
|
The operation mode cannot be changed. |
|
Does not cool or heat | |
The room cannot be cooled or heated sufficiently. |
|
The room cannot be cooled sufficiently. |
|
The room cannot be heated sufficiently. |
|
Air does not blow out soon in the heating operation. |
|
Airflow | |
The air from the indoor unit smells strange. |
|
Sound | |
Cracking sound is heard. |
|
“Burbling” sound is heard. |
|
Mechanical sound is heard from the indoor unit. |
|
The sound of water flowing is heard. |
|
Hissing sound is sometimes heard. |
|
Timer | |
Weekly timer does not operate according to settings. |
|
The unit starts/stops the operation by itself. |
|
In the following cases, stop using the air conditioner and consult your dealer.
- When water leaks or drips from the indoor unit.
- When the operation indicator lamp blinks.
- When the breaker trips frequently.
- The remote control signal is not received in a room where an electronic ON/ OFF type fluorescent lamp (inverter-type fluorescent lamp, etc.) is used.
- Operation of the air conditioner interferes with radio or TV reception. An amplifier may be required for the affected device.
- When an abnormal sound is heard.
- When any refrigerant leakage is found.
EMERGENCY OPERATION
When the remote controller cannot be used…
Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit.
Each time the E.O. SW is pressed, the operation changes in the following order:
Set temperature: 24°C Fan speed: Medium Horizontal vane: Auto |
Note:
- The first 30 minutes of operation is test run. Temperature control does not wok, and fan speed is set to High.
- In the emergency heating operation, the fan speed gradually rises to blow out warm air.
- In the emergency cooling operation, the horizontal vanes’ position will be reset in about a minute, then the operation will start.
AUTO RESTART FUNCTION
If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set with the remote controller just before the shutoff of the main power. When timer is set, timer setting is cancelled and the unit starts operation when power is resumed.
If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed.
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME
- Operate by COOL mode with the highest temperature set or FAN mode for 3 to 4 hours. (Check above)
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for growth of fungi, such as mold. - Press
to stop the operation
- Turn off the breaker and/or disconnect the power supply plug.
- Remove all batteries from the remote controller.
When using the air conditioner again:
- Clean the air filter. (Check above)
- Check that the air inlet and outlet of the indoor and outdoor units are not blocked.
- Check that the earth is connected correctly.
- Refer to the “PREPARATION BEFORE OPERATION”, and follow the instructions. (Check above)
INSTALLATION PLACE AND ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
- Where there is much machine oil.
- Salty places such as the seaside.
- Where sulfide gas is generated such as hot spring, sewage, waste water.
- Where oil is splashed or where the area is filled with oily smoke (such as cooking areas and factories, in which the properties of plastic could be changed and damaged).
- Where there is high-frequency or wireless equipment.
- Where the air from the outdoor unit air outlet is blocked.
- Where the operation sound or air from the outdoor unit bothers the house next door.
- The mounting height of indoor unit 1.8 m to 2.3 m is recommended. If it is impossible, please consult your dealer.
- Do not operate the air conditioner during interior construction and finishing work, or while waxing the floor. Before operating the air conditioner, ventilate the room well after such work is performed. Otherwise, it may cause volatile elements to adhere inside the air conditioner, resulting in water leakage or scattering of dew.
- Do not use the Wi-Fi interface nearby the medical electrical equipment or people who have a medical device such as a cardiac pacemaker or an implantable cardioverter-defibrillator.
It can cause an accident due to malfunctions of the medical equipment or device. - This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders.
- Do not use the Wi-Fi interface nearby other wireless devices, microwaves, cordless phones, or facsimiles.
It can cause malfunctions.
Electrical work
- Provide an exclusive circuit for the power supply of the air conditioner.
- Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
SPECIFICATIONS
Guaranteed operating range
Indoor |
Outdoor |
||
Cooling |
Upper limit | 32°C DB 23°C WB |
46°C DB — |
Lower limit | 21°C DB 15°C WB |
-10°C DB |
|
Heating |
Upper limit | 27°C DB — |
24°C DB 18°C WB |
Lower limit | 20°C DB — |
-15°C DB |
Wi-Fi interface
Model |
MAC-568IFB-E |
Input Voltage |
DC12.7 V (from indoor unit) |
Power consumption |
MAX. 2 W |
Size H×W×D (mm) |
79×44×18.5 |
Weight (g) |
60 (including cable) |
Transmitter power level (MAX.) |
17.5 dBm @IEEE 802.11b |
RF channel |
1ch ~ 13ch (2412~2472 MHz) |
Radio protocol |
IEEE 802.11b/g/n (20) |
Encryption |
AES |
Authentication |
WPA2-PSK |
Software Ver |
XX.00 |
Wi-Fi interface setting information
Indoor unit model name | |
Indoor unit serial number | |
Outdoor unit model name | |
Outdoor unit serial number | |
Wi-Fi interface MAC address (MAC) | |
Wi-Fi interface serial number (ID) | |
Wi-Fi interface PIN (PIN) | |
Wi-Fi interface SSID (SSID) | |
Wi-Fi interface KEY (KEY) | |
System commissioning date | |
Wi-Fi interface installation date |
Installer contact details
Name | |
Telephone number |
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
Documents / Resources
![]() |
Mitsubishi Split-Type Air Conditioners [pdf] Instruction Manual Split-Type Air Conditioners, MSZ-LN2 5V GV, MSZ-LN3 5V GV, MSZ-LN50 V GV, MSZ-LN60 V GV, MSZ-LN2 5V GR, MSZ-LN3 5V GR, MSZ-LN50 V GR, MSZ-LN60 V GR, MSZ-LN2 5V GB, MSZ-LN3 5V GB, MSZ-LN50 V GB, MSZ-LN60 V GB |