2025 Disk Tablet Micrometer

Product Specifications

  • Long range WIRELESS
  • Rechargeable
  • Calibration date
  • Linear correction
  • Temperature compensation
  • Analog scale
  • NON-ROTATING
  • Timer function
  • Formula calculation
  • Max/Min measurement
  • Go/NoGo indication
  • Preset modes
  • Graphic display

Product Usage Instructions

Switch On/Off and Data Transfer

To switch on the device, press the button for 1 second. To
switch off, press the button for 3 seconds or it will auto switch
off. Data transfer can be done through programming via the
menu.

Built-in Battery

The device has a rechargeable Li-Pol battery for
convenience.

Data Transfer Modes

The product offers three modes of data transfer: USB and two
wireless modes. It can connect wirelessly to the MICROTECH MDS app
for data transfer to Windows, Android, and iOS devices. Data can be
saved in XLS and CSV formats and transferred to CAD, SPC, or other
software.

Memory and Data Transfer to PC/Tablet

Data can be saved to internal memory by touching the screen or
pressing a button. Saved data can be viewed or sent via wireless or
USB connection to Windows PC, Android, or iOS devices. The device
offers standard or folders memory modes.

On-line Graphic Mode and Main Screen

The product features an on-line graphic mode displaying the last
value on the main screen. Connection status indicators show
wireless and USB HID connectivity.

Analog Scale and Probe Mode

Analog scale is active in the probe mode with color indications
for limits on the main screen. The device supports various
functions like LIMITS mode, GO/NOGO indication, and range
measurements.

Frequently Asked Questions (FAQ)

Q: How many ways are there to transfer data to a PC or
tablet?

A: There are seven ways to transfer data, including touchscreen
tap, button push, selected force, by timer, from memory, in MDS
app, and on-line graphic mode.

Q: What are the available memory modes for saving data?

A: The device offers standard or folders memory modes with a
capacity of 2000 values for data storage.

Q: Can the device connect wirelessly to any app or system?

A: Yes, the device supports wireless HID and USB HID connections
for data transfer to any customer’s app or system without the need
for a dongle.

“`

MICROTECH

DISK TABLET MICROMETER USER MANUAL

ISO17025:2017

ISO 9001:2015

MICROTECH

SPECIFICATION

Long range WIRELESS

Recharge

Calibr date

Linear corr

Temp comp

Analog scale

NON-ROTATING

Timer

Formula

Max/Min

Go/NoGo

Preset

Graphic

Item No

Range

Resolution

Accuracy

Disk

mm inch mm m mm

110780258 0-25 0-1”

±3

· · ··· · · · · · · ·

110780508 110780758

25-50 50-75

1-2” 2-3″

0,0001

±3 ±4

D 20

· ·

· ·

·· ··

· ·

· ·

· ·

· ·

· ·

· ·

· ·

· ·

110781008 75-100 3-4″

±4

· · ··· · · · · · · ·

Folders / 2000 Memory

USB HID /

USB

D 20MM

NON-ROTATING Analog scale
Graphic Preset Go/NoGo Max/Min Formula Timer Temp comp Linear corr Calibr date Recharge Memory WIRELESS USB

Item No

Range

Resolution

Accuracy

Disk

mm inch mm m mm

110780257 0-25 0-1”

±4

· · ··· · · · · · · ·

110780507 25-50 1-2”

±4

· · ··· · · · · · · ·

110780757 50-75 2-3″

±5

· · ··· · · · · · · ·

110781007 75-100 3-4″

±5

· · ··· · · · · · · ·

110781257 100-125 4-5″

±7

· · ··· · · · · · · ·

110781507 125-150 5-6″

±7

· · ··· · · · · · · ·

110781757 150-175 6-7″

±8

· · ··· · · · · · · ·

110782007 175-200 7-8″

±8

· · ··· · · · · · · ·

110782257 200-225 8-9″

±8

· · ··· · · · · · · ·

110782507 110782757

225-250 250-275

9-10″ 10-11″

0,0001

±8 ±8

D 35

· ·

· ·

··· ···

· ·

· ·

· ·

· ·

· ·

· ·

· ·

110783007 275-300 11-12″

±8

· · ··· · · · · · · ·

110783257 300-325 12-13″

±9

· · ··· · · · · · · ·

110783507 325-350 13-14″

±9

· · ··· · · · · · · ·

110783757 350-375 14-15″

±9

· · ··· · · · · · · ·

110784007 375-400 15-16″

±9

· · ··· · · · · · · ·

110784257 400-425 16-17″

±10

· · ··· · · · · · · ·

110784507 425-450 17-18″

±10

· · ··· · · · · · · ·

110784757 450-475 18-19″

±10

· · ··· · · · · · · ·

110785007 475-500 19-20″

±10

· · ··· · · · · · · ·

Folders / 2000 val Long range / HID USB HID / Update

D 35MM

MAIN INFO
SWITCH ON DEVICE – button push (1 sec) SWITCH OFF DEVICE – button push (3 sec)/ auto switch off DATA TRANSFER – programming throw menu
BUILT-IN BATTERY – rechargeable Li-Pol battery

DATA TRANSFER

MICROTECH

3 MODES OF DATA TRANSFER (USB + 2 WIRELESS MODES)

WIRELESS CONNECTION TO MDS APP
WIRELESS data transfer to MICROTECH MDS app for Windows, Android, iOS

SAVING DATA TO XLS. CSV FORMATS
TRANSFER DATA TO CAD, SPC OR OTHER
SOFTWARE

FREE SOFTWARE NO DONGLE

TRANSFER DATA TO EXCEL OR OTHER TABLE EDITORS
SAVING GRAPH

WIRELESS HID CONNECTION USB HID CONNECTION
NO DONGLE
WIRELESS HID and USB HID data transfer (like keyboard) direct to any customers app and system

TRANSFER DATA TO CAD, SPC OR OTHER
SOFTWARE
TRANSFER DATA TO EXCEL OR OTHER TABLE EDITORS
TRANSFER DATA TO ANY BROWSWE
OR APP

7 WAYS HOW TO TRANSFER DATA TO PC OR TABLET

TOUCHSCREEN TAP BUTTON PUSH

SELECTED FORCE

BY TIMER

FROM MEMORY

IN MDS APP

MICROTECH
ON-LINE GRAPHIC MODE
LAST VALUE

MAIN SCREEN
CONNECTION STATUS
WIRELESS DISCONNECTED WIRELESS CONNECTED WIRELESS HID CONNECTED USB HID DISCONNECTED USB HID CONNECTED
ANALOG SCALE

MEMORY
STANDARD or FOLDER system can be activated throw MEMORY menu
For save measuring data to internal device memory touch data area on screen or button push. You can view saved data or send by WIRELESS or USB connection to Windows PC, Android or iOS It’s possible to use Standard or Folders memory modes

ANALOG SCALE
FOR PROBE MODE
ON-LINE GRAPHIC MODE

FOLDERS SYSTEM MEMORY 2000 VAL. MEMORY EXPORT STATISTIC
MAIN SCREEN on 2D mode
2D AND HUB MODE
PROBE -Saving data when Probe will reach value PROBE Auto – Saving data when Probe will reach value with this value compensation 2D – 2 axis data reading 2D Sync- Synchronized 2 axis data reading

FUNCTIONS

MICROTECH

LIMITS mode GO/NOGO

COLOR INDICATION LIMITS ON MAIN SCREEN Go NoGo

MAX – NoGo more Upper limit

Upper limit

MIN – NoGo less Lower limit RANGE – Go between Limits NONE – Analog scale active

Lower limit Yellow zone on analog scale

PEAK mode MAX/MIN

INDICATION AND SAVING MAX OR MIN VALUES

DISABLE- non active mode ENABLE – activating mode

MAX – indicating MAX measured value

REFRESH – refresh peal value

MIN – indicating MIN measured value

according timer

TIMER mode

SAVING DATA TO MEMORY OR SENDING WIRELESS/USB BY TIMER

FORMULA mode

Select timer period Reset to disactivate mode

RESOLUTION selection

Select FORMULA Type (Math, Radius or other) Select arguments

Resolution selecting mm/inch conversion

DISPLAY settings
Sleep OFF (15 s low brightness off, sleep off) Sleep 15s (15 s low brightness on, sleep off) Sleep ON (15 s low brightness on, sleep on)
LINEAR error compensation
Re-calculation detail size to calibration conditions (20°C)
TEMP compensation
Manual Temperature setting

Display rotation 0°, 90°, 180°, 270°
Brightness level
Linear correction error’s on device
actual values correct values by up&down button confirm point correction
4 types of material for selection: – Glass, Quartz – Stainless steel – Cuprum and alloys – Alluminium and alloys

MICROTECH
WIRELESS data transfer
Recconection button Wireless power regulation

FUNCTIONS
ON – WIRELESS data transfer to MDS App for Android, iOS, Windows HID- WIRELESS HID direct transfer data to any App in Windows, MacOS, Linux, Android devices (like keyboard). Configure data format in USB sub-menu 2D-S – Slave device on WIRELESS connection on HUB mode 2D-M – Master device on WIRELESS connection on HUB mode

USB OTG data transfer

Connect USB cable to PC & Activate USB HID connection mode Select setting of data transfer Direct transfer data to any App in Windows, MacOS, Linux, Android devices
Configurating data transfer Dot/Comma and Tab/Arrow Down/CR+LF

HUB connection

PROBE MODE

A.C.on – Auto Connection active A.C.off – Auto Connection no active
PROBE -Saving data when Probe will reach value PROBE Auto – Saving data when Probe will reach value with this value compensation 2D – 2 axis data reading 2D Sync- Synchronized 2 axis data reading Setting PROBE limit value Disable – switch off modes

External Wireless device conneciton Axis priority selecting

A.C.on – Auto Connection active A.C.off – Auto Connection no active

PROBE -Saving data when Probe will reach value PROBE Auto – Saving data when Probe will reach value with this value compensation 2D – 2 axis data reading 2D Sync- Synchronized 2 axis data reading Disable – switch off modes

LINK to app’s

QR Link to MICROTECH web site page

with MDS Software download

– Android, iOS, Windows versions

– Free and Pro versions – Manuals

2D MODE
External Wireless device conneciton Symbol between Axis Graphic mode indication setting

RESET to Factory settings

Push 10 times to RESET device to factory settings Push 10 times to FIRMWARE UPDATE

FUNCTIONS
EXTRA
MEMORY manager setting
CALIBRATION date info

MICROTECH

Selecting normal or inverted axis mode (+/- value indication) oefficient setting (for distributor and calibration only)

Activating STANDARD or FOLDER SYSTEM
Values in each Folder

FOLDERS SYSTEM

Device INFO

Push for change calibration date info
Information about device – Firmware version – MAC adress for WIRELESS connection

TECHNICAL DATA

Parameters
LED display Indication system
Power supply Charging port
Case material Wireless data transfer
USB data transfer

color 2,4 inch 320×240 MICS 4.0
Rechargeable Li-Pol battery 500 mAh micro-USB
Aluminium Long range / HID
USB HID

DOWNLOAD APP

DOWNLOAD MDS APP FOR MICROTECH DEVICES WIRELESS CONNECTION FROM www.microtech.ua, GooglePlay & App Store

MICROTECH

INDUSTRY 4.0 INSTRUMENTS

0,1m

1m

FORCE CONTROL

1-20N

0,1m

0,1m
MICROTECH innovative measuring instruments
61001, Kharkiv, Ukraine, str. Rustaveli, 39 tel.: +38 (057) 739-03-50 www.microtech.ua tool@microtech.ua

1m
Change without prior notice

Documents / Resources

MICROTECH 2025 Disk Tablet Micrometer [pdf] User Manual
2025, 2025 Disk Tablet Micrometer, Disk Tablet Micrometer, Tablet Micrometer, Micrometer

References

Leave a comment

Your email address will not be published. Required fields are marked *