Specifications
Frequency: | 433.39 MHz |
Security: | 128-bit AES encryption |
Radio Range: | Up to 50 Metres |
Detection Range: | Up to 3 Metres |
Battery life: | Up to 3 Years |
Battery type: | 2 x AA Lithium Batteries 1.5v |
Mounting Style: | Post Mounted 600mm Above Ground |
e-LOOP Fitting Instructions ELPM
Step 1 – Coding e-LOOP
Coding e-LOOP with Magnet
- Power up the e-Trans 50, then press and release the CODE button. The blue LED on the e-Trans 50 will light up.
- Now place the magnet on the COD Erecess on the e-Loop – the yellow LED will flash 3 times, and the blue LED on the e-Trans 50 will flash 3 times. The systems are now paired and you can remove the magnet.
Option 2. Long-range coding with a magnet (up to 25 metres)
- Place the magnet on the CODE recess of the e-Loop, the yellow code LED will flash once now remove magnet and the LED come on solid, now walk over to the e-Trans 50 and press and release the CODE button, the yellow LED will flash and the blue LED on the e-Trans 50 will flash 3 times, after 15 seconds the e-Loop code LED will turn off.
Step 2 – Fitting e-LOOP
- Drill 2 holes approx. 163mm apart into your desired desired mounting location. With the Top hole approx. 600mm above ground level
- Insert the appropriate fasteners through the top & bottom mounting holes into your mounting surface. Screw down for a firm fit.
- Press the screw covers into the mounting holes
NOTE: Never fit near high voltage cables, this can affect the e-LOOP’s detection capability.
Step 3 – Calibrate e-LOOP
- Move any metal objects away from the e-LOOP.
Place magnet into the SET button recess on the e-LOOP until red - LED flashes twice, then remove the magnet.
- The e-LOOP will take about 5 seconds to calibrate and once complete, the red LED will flash 3 times.
NOTE: After calibration you may get an error indication.
ERROR 1: Low radio range – Yellow LED flashes 3 times.
ERROR 2: No radio connection – Yellow and Red LED flashes 3 times.
System is now ready.
Uncalibrate e-LOOP
- Place magnet into the SET button recess & hold until red LED flashes 4 times, e-LOOP is now uncalibrated.
Changing Mode
The e-LOOP is set to exit mode for the ELPM as default. To change the mode from exit mode to presence mode on the ELPM e-LOOP, use the menu via the e-TRANS-200 the Diagnostics remote or a magnet
Changing Mode using magnet
- Place the magnet on the CODE recess until the yellow LED is illuminated.
- Now place the magnet on the SET recess, the red LED will flash 1 time indicating EXIT MODE
- Place the magnet on the SET recess again, the LED will flash 2 times indicating PRESENCE MODE
- Place the magnet on the SET recess again, the LED will flash 3 times indicating PARKING MODE
- If you place the magnet on the SET recess again, the LED will flash 1 time indicating a return to EXIT MODE
- Now place magnet on CODE recess to confirm the changes. The changes will be made and the loop will go back to operational mode.
Resetting e-LOOP to Factory Defaults
Place and hold magnet on CODE recess until both LEDs flash twice. The unit is now reset to factory defaults. Note: this will also delete the transceiver from your loop, you will also need to delete the loop from the transceiver as well. (Refer to deleting codes on e-Trans instructions)