MICRO CONTROL SYSTEM LogoMCS-NITROMAG-15.4
Customer Installation Wiring
MCS-NITROMAG-15.4 CUSTOMER
INSTALLATION

MCS-IO-BASE WiFi – 2.4 GHz Nitro Mag

MICRO CONTROL SYSTEM MCS IO BASE WiFi 2.4 GHz Nitro Mag

  1. Remove all nuts from back of the touchscreen (10).
  2. Separate the face of the touchscreen from the Vesa Mount back.
  3. Lay the template (printed sheet supplied) on your enclosure, mark area for the cutout, 15.75 x 10.875 (40.05 x 27.6225cm).
  4. Mark the 10 holes to drill.
  5. Drill bit size – 3/16in (5mm).
  6. Cut out the hole for the touchscreen.
  7. Place the Touchscreen Face Plate through the cutout and secure the “4” corner ‘A’ nuts to the enclosure.
  8. Place the Vesa-Mount back onto the face plate studs, secure the remaining 8 nuts, making sure you do not over tighten the nuts. Tightening each nut around the frame, so the gasket is not pinched. Torque value 1 lbf.in

MICRO CONTROL SYSTEM MCS IO BASE WiFi 2.4 GHz Nitro Mag - QR Codehttps://mcscontrols.com/NitroMag.html

Wiring Diagram

MICRO CONTROL SYSTEM MCS IO BASE WiFi 2.4 GHz Nitro Mag - Wiring DiagramMICRO CONTROL SYSTEM MCS IO BASE WiFi 2.4 GHz Nitro Mag - Symbol Note: ALL 12V WIRING MUST BE 18-Gauge MINIMUM

MICRO CONTROL SYSTEM LogoJune 11, 2025 11:16 AM
5580 Enterprise Pkwy, Fort Myers, FL 33905 USA
Office: 239-694-0089 – Fax: 239-694-0031
www.mcxcontrols.comsupport@mcscontrols.com