Product Information
Specifications
- Model: CT-22 Speedometer
- Version: V1.1 (2018.1.27)
- Features: Clock adjustment, Metric and imperial system switching, Trip value reset, Brightness adjustment, Parameter adjustment
Product Usage Instructions
Clock Adjustment
To adjust the clock, press and hold the SET key for 10 seconds. The speed unit will switch between KPH and MPH. Repeat the process to switch back.
Metric and Imperial System Switching
In normal display mode, press and hold the SET key for 10 seconds to switch between metric (KPH) and imperial (MPH) systems.
Reset the Subtotal TRIP Value
To reset the subtotal TRIP value, press and hold the ADJ key for 3 seconds while in normal display mode.
Brightness Adjustment
The backlight brightness cannot be adjusted as it remains constant.
Adjust the Parameters of Speedometer
To adjust the parameters, enter the password 6610. Use the SET key to navigate through different parameters and modify values as needed.
FAQ
- What is the default password for adjusting parameters?
- The default password for adjusting parameters is 6610.
- How can I reset the total TRIP value?
- To reset the total TRIP value, refer to the user manual for specific instructions.
“`
- Clock adjustment
In normal display mode, press and hold the ADJ key to turn on the display, and the minute digit will flash. At this time, each short press of the ADJ key will increase the minute value by 1, and long press of the ADJ key will continuously increase the minute value until the key is released. After adjusting the minutes, short press the SET key, and the hour digit will flash. At this time, each short press of the ADJ key will increase the hour value by 1, and long press of the ADJ key will continuously increase the hour value until the key is released. After completing the setting, save the parameter setting and exit. - Metric and imperial System Switching
In normal display mode, press and hold the SET key for 10 seconds, and the speed unit will switch from KPH to MPH. To switch back, press and hold the SET key again for another 10 seconds. - Reset the subtotal TRIP value
In normal display mode, press and hold the ADJ key for 3 seconds, the subtotal TRIP value will be reset - Reset the total TRIP value
Press and hold the SET key to turn on the display, enter the password operation interface, at this time the screen displays P-0000, the rightmost digit is selected, and it flashes at a frequency of 1Hz. In this interface, short press the SET key will increase the number on the selected digit by 1, and the value of the number on the digit will cycle between 0 and 9; Long press the SET key will select the digit one place higher. After the 4-digit number is entered, if the value is 8810, the global TRIP value will be reset; if the value is 6810, the setting interface will be entered; if the value is other, it will return to the password operation interface and display P-0000. - Brightness Adjustment
Can’t be adjusted , the backlights always have same brightness. - Adjust the parameters of speedometer
All the following screen adjustments are for the speedometer section only and are unrelated to other sections. The upper computer is set to use MPH as the speed unit, and KPH is used as the speed unit in the text document modification. If the speed or mileage 60KPH frequency is not modified during the modification, it will maintain the last set value. If the speed or mileage 60KPH frequency is modified, it will be switched to the corresponding metric speedometer.
Press and hold the SET key to open the display and enter the password operation interface. At this time, the screen displays P-0000, and the rightmost digit is selected and flashes at a frequency of 1Hz. In this interface, short press the SET key will increase the number on the selected digit by 1, and the value of the number on the digit will cycle between 0 and 9; long press the SET key will select the digit one place higher. After the 4-digit number is entered, if the value is 6610, the vehicle speed ratio setting interface will be entered; if the value is 8810, the cumulative value will be cleared; if the value is 6810, the cumulative setting interface will be entered; if it is other values, it will return to the password operation interface and display P-0000.
Parameter set(password:6610)
Display content | Define | Notes |
P-0000 | password operation interface | P-6610 to enter the parameters setting surface. |
0-0420 | 420Hz, corresponding speed of 60KPH. | Modifiable, value 0-999. |
1-0420 | 420Hz, corresponding speed of 60KPH. | Modifiable, value 0-999. |
2-1320 | The voltage value corresponding to 20% battery level while charging. | 1320 means 132V. |
3-1370 | The voltage value corresponding to 40% battery level while charging. | 1370 means 137V. |
4-1420 | The voltage value corresponding to 60% battery level while charging. | 1420 means 142V. |
5-1460 | The voltage value corresponding to 80% battery level while charging. | 1460 means 146V. |
6-1520 | The voltage value corresponding to 40% battery level while charging. | 1520 means 152V. |
7-1320 | The voltage value corresponding to 20% battery level while discharging | 1320 means 132V. |
8-1370 | The voltage value corresponding to 40% battery level while discharging. | 1370 means 137V. |
9-1420 | The voltage value corresponding to 60% battery level while discharging. | 1420 means 142V. |
A-1460 | The voltage value corresponding to 80% battery level while discharging. | 1460 means 146V. |
B-1520 | The voltage value corresponding to 40% battery level while discharging. | 1520 means 152V. |
C-0300 | Coulomb-meter full power deboost time , Use seconds as unit. | 300 means 300 seconds. |
D-1250 | The voltage value corresponding to 0% battery level while charging. | 1250 means 125V. |
E-1250 | The voltage value corresponding to 40% battery level while discharging. | 1250 means 125V. |
F-0001 | Charging memory | 1 means 1%, long press SET key for 48s to clear. |
R0 | Low voltage warning value | (Reserved),not available on CY1874D_MB110D |
J-0030 | Battery power judge time | 30 means 30 seconds. |
When entering the parameter setting interface, the screen will statically display 0-0420. In this state, short press the SET key to advance to the next parameter 1-0420. Long press the SET key to enter the value modification mode. At this time, the rightmost digit is selected, and it flashes at 1Hz. Short press the SET key to select the digit and add 1 to the digit value, which cycles between 0 and 9. Long press the SET key to select the higher digit. After the highest digit is set, long press the SET key to exit “0” and complete the setting. Then the screen will statically display 0-0420. Short press the SET key to switch to 1-0420 and set it, and so on. During the battery judgment time, if the voltage changes exceed the set value of the battery change rate, the pointer will update to the new value after the time is greater than the maximum time, otherwise the current position will be maintained. If the voltage change is less than the set value of the battery change rate, the pointer will be updated directly to the new value. Pressing the SET key again in the J-0030 interface will exit the entire setting operation. The instrument will automatically run according to the new parameters.
If you only need to modify the speed ratio, after the speed ratio is modified, when you jump to the 1-0420 interface, turn off the instrument and then restart it. The instrument will run using the new parameters.
Total reset (password:8810)
Display content | Define | Notes |
P-0000 | password operation interface | P-8810 to enter the total reset surface |
000000 | Total auto reset | Esc after shows 1 seconds , the speedometer run normally |
Total reset setting(password:6810)
Display content | Define | Notes |
P-0000 | password operation interface | P-6810 to enter the total setting surface |
xxxxxxx | Total value reset | Free, Auto clear |
- Yellow is going to Main battery pack Positive.
- Red is going to Positive of Main battery pack, thorough a key switch.
- Green-black should be connected to GND of Main batterry pack.
- Green should be going to GND of 12V DCDC converter.
Documents / Resources
![]() |