MEAN WELL XLC-60-KN Series 60W Multiple Stage Constant Power LED Driver
Features
- Constant power mode output with multiple stage, selectable by ETS database
- Plastic housing with class Il and PFC design
- Flicker-free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) application
- KNX/EIB protocol, support KNX data security
- Minimum dimming level 0.5%
- Functions: operation hours. power consumption feedback log/linear curve selection… etc
- 5 years warranty
Applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- KNX digital Lighting
GTIN CODE
- MW Search: https:/www.meanwell.com/serviceGTIN.aspx
Description
- XLC-60-KN Series is a 60W with constant power output LED driver. It can operate from 100 ~ 305 VAC and output current ranging between 900mA to 1700mA selectable by ETS database and integration KNX interface to avoid using the compliated KNX-DALI gateway. Thanks to high efficiency up to 90%, it can operate for -25°C ~90°C case temperature under free air convection. XLC-60-KN is designed based on the latest safety regulations, so it provides more flexibility for LED Lighting applications.
Model Encoding
SPECIFICATION
NOTE
- All parameters NOT specially mentioned are measured at 230VAC input, rated current, and 25 C of ambient temperature.
- Output hiccups under no-load condition.
- Please refer to “DRIVER METHODS OF LED MODULE”.
- De-rating may be needed under low input voltages. Please refer tothe “STATIC CHARACTERISTIC” sections for details.
- The current ripple is measured at 50% ~ 100% of maximum voltage under rated power delivery.
- The length of setup time is measured at first cold start. Turning ON/OFF the driver on or off may lead to an increase in the setup time.
- Efficiency is measured at 1050mA/54V output set by ETS database.
- Standby power consumption is measured at 230V AC.
- Flicker is measured at full load with the light source provided by MEAN WELL.
- The driver is considered as a component that will be operated in combination with the final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- For the XLC-S series: RCM is on a voluntary basis. Non-IC classification Independent LED control gear is not suitable for residential installations. For the XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards, complying with AS/NZS 4417.1.
- The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly to point (or TMP, per DLC), is about 75 C or less.
- For more information, please contact MEAN WELL sales.
* Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.asp
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULES
CONSTANT POWER TABLE
XLC-60-KN is a multiple-stage constant power driver, selection of output current through Database.
Vo | Io | Vo | Io |
9~54V | 900mA(Default) | 9~45V | 1350mA |
9~54V | 950mA | 9~43V | 1400mA |
9~54V | 1000mA | 9~41V | 1450mA |
9~54V | 1050mA | 9~40V | 1500mA |
9~54V | 1100mA | 9~39V | 1550mA |
9~52V | 1150mA | 9~38V | 1600mA |
9~50V | 1200mA | 9~37V | 1650mA |
9~48V | 1250mA | 9~36V | 1700mA |
9~46V | 1300mA |
DIMMING OPERATION
KNX interface
- Apply KNX Bus cable between KNX+ and KNX-
- The application program(database) can be downloaded via Online Catalogs from ETS or via http://www.meanwell.com/productCatalog.aspx
Parametrization options | Description |
Device Setting |
• Select current level
• Select model • Behavior bus power up |
Parameter Setting |
• Basic Setting
• Normal dimmer, staircase light • Switch function •relative dimming function • Absolution dimming function • Feedback Setting • Dimming value report •on/off state report • Lamp failure report • Lock function |
Scenes | • Learn scene
• scene1~scene32 |
Automatic function | • Automatic function1~4 |
operating hours |
• Counting of operating hours
• Constant light output(CLO) • Lifetime pre-warning |
Power consumption | • Voltage, current, and power feedback
• Energy consumption feedback |
Temperature Measurement | • customize the alarm temperature
• Send temperature report cyclically |
Auto-dimming over time | • Optional gradient dimming |
Correction characteristic | • Correction by lux measured value(lux) |
Push Dim Port | • Push dim
• AC monitor |
CONSTANT LIGHT OUTPUT
PUSH dimming or AC/DC input monitor(Primary side)
- PUSH dimming
- KNX bus needs to be connected when using PUSH Dimming
- For the detailed function of PUSH dimming, please refer to the database.
- The maximum length of the cable between the push button and driver is 20 meters.
- The mechanical push button can be connected only between the PUSH terminal, as displayed in the diagram, and AC/L (in brown or black); It will not function properly if it is connected to AC/N.
- In case the PUSH dimming is set locally, up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
- In case the PUSH dimming is set independently via ETS, the number of drivers is done through group address and determined by the ETS project designer.
AC/DC input monitor
- KNX bus needs to be connected when using the AC/DC input monitor
- For the detailed function of the AC/DC input monitor(emergency lighting), please refer to the database and instruction manual.
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
LIFE TIME
TOTAL HARMONIC DISTORTION (THD)
POWER FACTOR (PF) CHARACTERISTIC
XLC-60-H-KN Model, Tcase at 75℃
EFFICIENCY vs LOAD
XLC-60-KN series possess superior working efficiency that up to 90% can be reached in field applications.
XLC-60-H-KN Model, Tcase at 75℃
MECHANICAL SPECIFICATION
Installation Manual
- Please refer to: http://www.meanwell.com/manual.html
FAQ
- Q: What is the maximum power factor of the LED driver?
- A: The LED driver has a power factor of [insert power factor value here].
- Q: How many LED drivers can be connected to a 16A circuit breaker?
- A: The maximum number of LED drivers that can be connected to a 16A circuit breaker is [insert number here].
Documents / Resources
![]() |
MEAN WELL XLC-60-KN Series 60W Multiple Stage Constant Power LED Driver [pdf] Owner's Manual XLC-60-KN, XLC-60-H-KN, XLC-60-KN Series 60W Multiple Stage Constant Power LED Driver, XLC-60-KN Series, 60W Multiple Stage Constant Power LED Driver |