MEAN-WELL -logo

MEAN WELL XLC-60-KN Series 60W Multiple Stage Constant Power LED Driver

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-product

Features

  • Constant power mode output with multiple stage, selectable by ETS database
  • Plastic housing with class Il and PFC design
  • Flicker-free, complying with CE ErP directive
  • Standby power consumption <0.5W
  • Meet emergency lighting (EL) application
  • KNX/EIB protocol, support KNX data security
  • Minimum dimming level 0.5%
  • Functions: operation hours. power consumption feedback log/linear curve selection… etc
  • 5 years warranty

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-1

Applications

  • Recessed Light
  • Down Light
  • Panel Light
  • Commercial Lighting
  • Decorative Lighting
  • KNX digital Lighting

GTIN CODE

Description

  • XLC-60-KN Series is a 60W with constant power output LED driver. It can operate from 100 ~ 305 VAC and output current ranging between 900mA to 1700mA selectable by ETS database and integration KNX interface to avoid using the compliated KNX-DALI gateway. Thanks to high efficiency up to 90%, it can operate for -25°C ~90°C case temperature under free air convection. XLC-60-KN is designed based on the latest safety regulations, so it provides more flexibility for LED Lighting applications.

 Model Encoding

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-2

SPECIFICATION

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-3MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-4

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current, and 25 C of ambient temperature.
  2. Output hiccups under no-load condition.
  3. Please refer to “DRIVER METHODS OF LED MODULE”.
  4. De-rating may be needed under low input voltages. Please refer tothe  “STATIC CHARACTERISTIC” sections for details.
  5. The current ripple is measured at 50% ~ 100% of maximum voltage under rated power delivery.
  6. The length of setup time is measured at first cold start. Turning ON/OFF the driver on or off may lead to an increase in the setup time.
  7. Efficiency is measured at 1050mA/54V output set by ETS database.
  8. Standby power consumption is measured at 230V AC.
  9. Flicker is measured at full load with the light source provided by MEAN WELL.
  10. The driver is considered as a component that will be operated in combination with the final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  11. For the XLC-S series: RCM is on a voluntary basis. Non-IC classification Independent LED control gear is not suitable for residential installations. For the XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards, complying with AS/NZS 4417.1.
  12. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
  13. This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly to point (or TMP, per DLC), is about 75 C or less.
  14. For more information, please contact MEAN WELL sales.

* Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.asp

BLOCK DIAGRAM

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-5

DRIVING METHODS OF LED MODULES

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-6

CONSTANT POWER TABLE

XLC-60-KN is a multiple-stage constant power driver, selection of output current through Database.

Vo Io Vo Io
9~54V 900mA(Default) 9~45V 1350mA
9~54V 950mA 9~43V 1400mA
9~54V 1000mA 9~41V 1450mA
9~54V 1050mA 9~40V 1500mA
9~54V 1100mA 9~39V 1550mA
9~52V 1150mA 9~38V 1600mA
9~50V 1200mA 9~37V 1650mA
9~48V 1250mA 9~36V 1700mA
9~46V 1300mA

DIMMING OPERATION

KNX interface

Parametrization options Description
 

Device Setting

• Select current level

• Select model

• Behavior bus power up

 

 

 

 

Parameter Setting

• Basic Setting

• Normal dimmer, staircase light

• Switch function

•relative dimming function

• Absolution dimming function

• Feedback Setting

• Dimming value report

•on/off state report

• Lamp failure report

• Lock function

Scenes • Learn scene

• scene1~scene32

Automatic function • Automatic function1~4
 

operating hours

• Counting of operating hours

• Constant light output(CLO)

• Lifetime pre-warning

Power consumption • Voltage, current, and power feedback

• Energy consumption feedback

Temperature Measurement • customize the alarm temperature

• Send temperature report cyclically

Auto-dimming over time • Optional gradient dimming
Correction characteristic • Correction by lux measured value(lux)
Push Dim Port • Push dim

• AC monitor

CONSTANT LIGHT OUTPUT

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-8

PUSH dimming or AC/DC input monitor(Primary side)

  • PUSH dimming

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-9

  • KNX bus needs to be connected when using PUSH Dimming
  • For the detailed function of PUSH dimming, please refer to the database.
  • The maximum length of the cable between the push button and driver is 20 meters.
  • The mechanical push button can be connected only between the PUSH terminal, as displayed in the diagram, and AC/L (in brown or black); It will not function properly if it is connected to AC/N.
  • In case the PUSH dimming is set locally, up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
  • In case the PUSH dimming is set independently via ETS, the number of drivers is done through group address and determined by the ETS project designer.

AC/DC input monitor

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-10

  • KNX bus needs to be connected when using the AC/DC input monitor
  • For the detailed function of the AC/DC input monitor(emergency lighting), please refer to the database and instruction manual.

OUTPUT LOAD vs TEMPERATURE

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-11

STATIC CHARACTERISTIC

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-12

LIFE TIME

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-13TOTAL HARMONIC DISTORTION (THD)

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-14

POWER FACTOR (PF) CHARACTERISTIC

XLC-60-H-KN Model, Tcase at 75℃

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-20

EFFICIENCY vs LOAD

XLC-60-KN series possess superior working efficiency that up to 90% can be reached in field applications.

XLC-60-H-KN Model, Tcase at 75℃

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-15MECHANICAL SPECIFICATION

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-16MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-17MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-18

Installation Manual

MEAN-WELL XLC-60-KN-Series-60W-Multiple-Stage-Constant-Power-LED-Driver-fig-19

FAQ

  • Q: What is the maximum power factor of the LED driver?
  • A: The LED driver has a power factor of [insert power factor value here].
  • Q: How many LED drivers can be connected to a 16A circuit breaker?
  • A: The maximum number of LED drivers that can be connected to a 16A circuit breaker is [insert number here].

Documents / Resources

MEAN WELL XLC-60-KN Series 60W Multiple Stage Constant Power LED Driver [pdf] Owner's Manual
XLC-60-KN, XLC-60-H-KN, XLC-60-KN Series 60W Multiple Stage Constant Power LED Driver, XLC-60-KN Series, 60W Multiple Stage Constant Power LED Driver

References

Leave a comment

Your email address will not be published. Required fields are marked *