UHP-1500-HV series
1500W Conduction Cooling with High Voltage Output
https://www.meanwell.com/webapp/product/search.aspx?prod=UHP-1500&pdf=VUhQLTE1MDAtRS5QREY=&a=4
Features
- High voltage output (115/230/380V)
- Fanless and conduction-cooled design
- Slim and 1U Low profile (41mm)
- Built-in active PFC function
- DC 12V/0.4A auxiliary power
- Output voltage and constant current level programmable (PV/PC)
- Protections: Short circuit / Over load/ Over voltage / Over temperature
- Built-in remote ON-OFF control and DC OK signal
- Operating altitude up to 2000 meter (E type Note.6, Blank/PM/CAN type Note.7)
- LED indicator for power on
- Optional PMBus or CANBus protocol
- 5 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment or apparatus
- Test and measurement instrument
- Laser related machine
- Charging related equipment
- DC centralized bus(Lighting)
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
UHP-1500 series is a 1500W single-output slim type power supply with 1U 41mm of low profile design.
Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 115V/230V and 380V. In addition to the high efficiency up to 95.5%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-1500 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1.
UHP-1500 series serves as a high performance power supply solution for various industrial and DC centralized bus applications.
Model Encoding
Type | Communication Protocol | Note |
Blank | with programming PV/PC | ln Stock |
E | DC 380V only without PV/PC | ln Stock |
PM | PMBus protocol with PV/PC | By request |
CAN | CANBus protocol with PV/PC | By request |
Note: E type without PV/PC and communication protocol.
SPECIFICATION ( E type )
MODEL | UHP-1500-380E | |||
OUTPUT | DC VOLTAGE(DEFAULT) | 380V | ||
RATED CURRENT (Max.) | 3.95A | |||
RATED POWER (Max.)(Note.7) | 1501W | |||
RIPPLE & NOISE (Max.) Note.2 | 3800mVp-p | |||
VOLTAGE ADJ. RANGE | By built-in potentiometer, SVR | |||
350~420V | ||||
VOLTAGE TOLERANCE Note.3 | ±1.0% | |||
LINE REGULATION | ±0.5% | |||
LOAD REGULATION | ±0.5% | |||
SETUP, RISE TIME | 1800ms, 60ms/230VAC at full load | |||
HOLD UP TIME (Typ.) | 16ms/230VAC at 75% load 10ms/230VAC at full load | |||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 250 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
POWER FACTOR (Typ.) | PF≥0.95/230VAC at full load | |||
EFFICIENCY (Typ.) | 95.5% | |||
AC CURRENT (Typ.) | 8A/230VAC | |||
INRUSH CURRENT (Typ.) | Cold start 60A/230VAC | |||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||
PROTECTION | OVER LOAD | 105~125% rated output power | ||
Protection type : Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover. | ||||
SHORT CIRCUIT | Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover. | |||
OVER VOLTAGE | 428 ~ 460V | |||
Protection type :Shut down O/P voltage,re-power on to recover | ||||
OVER TEMPERATURE | Protection type :Shut down O/P voltage, recovers automatically after temperature goes down | |||
FUNCTION | REMOTE ON/OFF CONTROL | Power ON : Short circuit Power OFF : Open circuit | ||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve”) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC (Note.6) | SAFETY STANDARDS | UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved | ||
WITHSTAND VOLTAGE Note 8 | OVC Ⅲ I/P-O/P:6KVDC I/P-FG:4KVDC O/P-FG:4KVDC | |||
ISOLATION RESISTANCE Note 8 | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | |||
EMC EMISSION | Parameter | Standard | Test Level / Note | |
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||
EMC IMMUNITY | BS EN/EN61000-6-2 | |||
Parameter | Standard | Test Level / Note | ||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-6-2 | 2KV/Line-Line 4KV/Line-Earth | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods | ||
OTHERS | MTBF | 597.3K hrs min. Telcordia SR-332 (Bellcore) ; 63.3K hrs min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 290*140*41mm (L*W*H) | |||
PACKING | 2.51kg ; 6pcs/16.06kg/0.91CUFT | |||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance :includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 7. Refer to derating curve. ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
SPECIFICATION (Blank/PM/CAN type)
MODEL | UHP-1500-115 | UHP-1500-230 | UHP-1500-380 | ||
OUTPUT | DC VOLTAGE (DEFAULT) | 115V | 230V | 380V | |
CURRENT (FACTORY DEFAULT) | 13.05A | 6.52A | 3.95A | ||
RATED CURRENT (Max.) | 13.05A | 6.95A | 4.5A | ||
POWER (FACTORY DEFAULT) | 1500.75W | 1500W | 1500W | ||
RATED POWER (Max.)(Note.9) | 1500.75W | 1501.2W | 1503W | ||
RIPPLE & NOISE (Max.) Note.2 | 1150mVp-p | 2300mVp-p | 3800mVp-p | ||
FULL POWER VOLTAGE RANGE | 115~138V | 216~260V | 334~400V | ||
VOLTAGE ADJ. RANGE | By built-in potentiometer, SVR | ||||
90~138V | 170~260V | 260~400V | |||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ||
SETUP, RISE TIME | 1800ms, 60ms/230VAC at full load | ||||
HOLD UP TIME (Typ.) | 16ms/230VAC at 75% load 10ms/230VAC at full load | ||||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 250 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF≥0.95/230VAC at full load | ||||
EFFICIENCY (Typ.) | 95% | 95% | 95.5% | ||
AC CURRENT (Typ.) | 8A/230VAC | ||||
INRUSH CURRENT (Typ.) | Cold start 60A/230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||
PROTECTION | OVER LOAD | 105~125% rated output power | |||
Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover. | |||||
SHORT CIRCUIT | Constant current limiting, unit will shutdown after 5 sec, re-power on to recover. | ||||
OVER VOLTAGE | 145 ~175V | 273 ~ 325V | 420 ~ 460V | ||
Protection type :Shut down O/P voltage,re-power on to recover | |||||
OVER TEMPERATURE | Protection type :Shut down O/P voltage, recovers automatically after temperature goes down | ||||
FUNCTION | OUTPUT VOLTAGE PROGRAMMABLE(PV) Note 5 | Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage Please refer to the Function Manual. | |||
OUTPUT CURRENT PROGRAMMABLE(PC) Note 5 | Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual. | ||||
REMOTE ON/OFF CONTROL | Power ON : Short circuit Power OFF : Open circuit | ||||
AUXILIARY POWER | 12V @ 0.4A tolerance ±10%, ripple=150mVp-p | ||||
DC-OK SIGNAL | The TTL signal out, PSU turn on = 4.4 ~ 5.5V ; PSU turn off = -0.5 ~ 0.5V. Please refer to the Function Manual. | ||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY & EMC (Note.6) | SAFETY STANDARDS | UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved | |||
WITHSTAND VOLTAGE Note 8 | OVC Ⅲ I/P-O/P:6KVDC I/P-FG:4KVDC O/P-FG:4KVDC | ||||
ISOLATION RESISTANCE Note 8 | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | ||||
EMC EMISSION | Parameter | Standard | Test Level / Note | ||
Conducted | BS EN/EN55032 (CISPR32) | Class B | |||
Radiated | BS EN/EN55032 (CISPR32) | Class A | |||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||
EMC IMMUNITY | BS EN/EN61000-6-2 | ||||
Parameter | Standard | Test Level / Note | |||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | |||
Surge | BS EN/EN61000-6-2 | 2KV/Line-Line 4KV/Line-Earth | |||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | 95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods |
|||
OTHERS | MTBF | 597.3K hrs min. Telcordia SR-332 (Bellcore) ; 63.3K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 290*140*41mm (L*W*H) | ||||
PACKING | 2.51kg ; 6pcs/16.06kg/0.91CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance :includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. PV/PC functions when users do not use SVR. 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. Refer to derating curve. ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
BLOCK DIAGRAM
STATIC CHARACTERISTIC
EFFICIENCY VS LOAD (380V MODEL)
DERATING CURVE
FUNCTION MANUAL ( For E type)
- Output Voltage
- Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units in parallel by using the “Remote ON-OFF” function.
Remote ON-OFF | Power Supply Status |
Short circuit | ON |
Open circuit | OFF |
FUNCTION MANUAL (Blank/PM/CAN type)
- Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 50%~120% by applying EXTERNAL VOLTAGE.
※ When PC/PV are used at the same time, PC is preferred - Constant Current Programming (or, PC / remote current programming / dynamic current trim)
※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE.
In PC mode, the output current shall meet the output voltage / output current reduction curve.◎ Covered by over temperature protection auto de-rating function works under operation either in PC mode or under control by communication protocol.
T1(Typ.): Maximum ambient temperature of full load.
T2(Typ.): T1+5.℃ - Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units in parallel by using the “Remote ON-OFF” function.Remote ON-OFF Power Supply Status Short circuit ON Open circuit OFF - DC-OK Signal
DC-OK signal is a TTL level signal. The maximum sink current is 10mA and the maximum external voltage is 5.6V.DC-OK signal Power Supply Status “High” >4.4~5.5V ON “Low” <-0.5~0.5V OFF - PMBus Communication Interface
UHP-1500 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details, please refer to the Function Manual.
MECHANICAL SPECIFICATION (For E type)
AC Input Terminal(TB1) Pin NO. Assignment
Pin No. | Assignment | Terminal | Max mounting torque |
1 | AC/L | DG58S | 18Kgf-cm |
2 | AC/N | ||
3 | ![]() |
DC Output Terminal(TB2,TB3) Pin NO. Assignment
Pin No. | Assignment | Terminal | Max mounting torque |
TB2 | +V | (MW) HS455A | 8Kgf-cm |
TB3 | -V |
※Control Pin No. Assignment(CN82) : HRS DF11-04DP-2DS or equivalent
Pin No. | Function | Description |
1,2 | Remote ON-OFF | The unit can turn the output ON/OFF by dry contact between Remote ON/OFF and GND |
3,4 | GND |
MECHANICAL SPECIFICATION (Blank/PM/CAN type)
AC Input Terminal(TB1) Pin NO. Assignment
Pin No. | Assignment | Terminal | Max mounting torque |
1 | AC/L | DG58S | 18Kgf-cm |
2 | AC/N | ||
3 | ![]() |
DC Output Terminal(TB2,TB3) Pin NO. Assignment
Pin No. | Assignment | Terminal | Max mounting torque |
TB2 | +V | (MW) HS455A | 8Kgf-cm |
TB3 | -V |
※DIP SW:
Pin No. | Function | Description |
1 | A0 | PMBus / CANBus interface address switch. |
2 | A1 | |
3 | A2 |
※Control Pin No. Assignment(CN71) : HRS DF11-04DP-2DS or equivalent
Mating Housing | HRS DF11-04DS or equivalent |
Terminal | HRS DF11-**SC or equivalent |
※Control Pin No. Assignment(CN77) : HRS DF11-08DP-2DS or equivalent
Mating Housing | HRS DF11-08DS or equivalent |
Terminal | HRS DF11-**SC or equivalent |
※Control Pin No. Assignment(CN77) : HRS DF11-04DP-2DS or equivalent
Pin No. | Function | Description |
1 | PV | Connection for output voltage programming.(Note1) |
2 | PC | Connection for constant current level programming.(Note.1) |
3,4 | GND (Signal) | Negative output voltage signal. |
※Control Pin No. Assignment(CN77) : HRS DF11-04DP-2DS or equivalent
Pin No. | Function | Description |
1,2 | +12V-AUX | Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin3 & 4). The maximum load current is 0.4A. This output is not controlled by “Remote ON-OFF”. |
3.4 | GND-AUX | Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). |
5 | Remote ON-OFF | The unit can turn the output ON/OFF by dry contact between Remote ON/OFF and 12-AUX.(Note.2) Short (10.8 ~ 13.2V) : Power ON ; Open(-0.5 ~ 0.5V) : Power OFF ; The maximum input voltage is 13.2V |
6 | DC-OK | Low (-0.5 ~ 0.5V) : When the Vout≦77%±6%. High (4.5 ~ 5.5V) : When Vout≧80%±6%. The maximum sourcing current is 10mA and only for output.(Note.2) |
7 | SCL | For PMBus model: Serial Clock used in the PMBus interface. (Note.2) |
CANH | For CANBus model: Data line used in CANBus interface. (Note.2) | |
8 | SDA | For PMBus model: Serial Data used in the PMBus interface. (Note.2) |
CANL | For CANBus model: Data line used in CANBus interface. (Note.2) |
Note1: Non-isolated signal, referenced to [GND(signal)].
Note2: Isolated signal, referenced to GND-AUX.
INSTALLATION
- Operate with additional aluminum plate
In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-1500-HV series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-1500-HV series must be firmly mounted at the center of the aluminum plate. - With 40 CFM forced air
Documents / Resources
![]() |
MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series [pdf] Installation Guide UHP-1500-HV 1500W Conduction Cooling with High Voltage Output, UHP-1500-HV, 1500W Conduction Cooling with High Voltage Output, Cooling with High Voltage Output, High Voltage Output, Voltage Output, Output |