UHP-1500-HV series
1500W Conduction Cooling with High Voltage Output

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Symbol 1

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Symbol 2

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - QR Code

https://www.meanwell.com/webapp/product/search.aspx?prod=UHP-1500&pdf=VUhQLTE1MDAtRS5QREY=&a=4

Features

  • High voltage output (115/230/380V)
  • Fanless and conduction-cooled design
  • Slim and 1U Low profile (41mm)
  • Built-in active PFC function
  • DC 12V/0.4A auxiliary power
  • Output voltage and constant current level programmable (PV/PC)
  • Protections: Short circuit / Over load/ Over voltage / Over temperature
  • Built-in remote ON-OFF control and DC OK signal
  • Operating altitude up to 2000 meter (E type Note.6, Blank/PM/CAN type Note.7)
  • LED indicator for power on
  • Optional PMBus or CANBus protocol
  • 5 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment or apparatus
  • Test and measurement instrument
  • Laser related machine
  • Charging related equipment
  • DC centralized bus(Lighting)

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

UHP-1500 series is a 1500W single-output slim type power supply with 1U 41mm of low profile design.
Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 115V/230V and 380V. In addition to the high efficiency up to 95.5%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-1500 has the complete protection functions and 5G anti-vibration capability; It is complied with the international safety regulations such as TUV BS EN/EN62368-1, UL62368-1.
UHP-1500 series serves as a high performance power supply solution for various industrial and DC centralized bus applications.

Model Encoding

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Fig 1

Type Communication Protocol Note
Blank with programming PV/PC ln Stock
E DC 380V only without PV/PC ln Stock
PM PMBus protocol with PV/PC By request
CAN CANBus protocol  with PV/PC By request

Note: E type without PV/PC and communication protocol.

SPECIFICATION ( E type )

MODEL UHP-1500-380E
OUTPUT DC VOLTAGE(DEFAULT) 380V
RATED CURRENT (Max.) 3.95A
RATED POWER (Max.)(Note.7) 1501W
RIPPLE & NOISE (Max.) Note.2 3800mVp-p
VOLTAGE ADJ. RANGE By built-in potentiometer, SVR
350~420V
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±0.5%
SETUP, RISE TIME 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC at 75% load      10ms/230VAC at full load
INPUT VOLTAGE RANGE        Note.4 90 ~ 264VAC        250 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≥0.95/230VAC at full load
EFFICIENCY (Typ.) 95.5%
AC CURRENT (Typ.) 8A/230VAC
INRUSH CURRENT (Typ.) Cold start 60A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
PROTECTION OVER LOAD 105~125% rated output power
Protection type : Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover.
SHORT CIRCUIT Constant current limiting, unit will shutdown after 2-5 sec, re-power on to recover.
OVER VOLTAGE 428 ~ 460V
Protection type :Shut down O/P voltage,re-power on to recover
OVER TEMPERATURE Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION REMOTE ON/OFF CONTROL Power ON : Short circuit         Power OFF : Open circuit
ENVIRONMENT WORKING TEMP. -30 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.6) SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE Note 8 OVC Ⅲ I/P-O/P:6KVDC   I/P-FG:4KVDC   O/P-FG:4KVDC
ISOLATION RESISTANCE Note 8 I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
EMC EMISSION Parameter Standard Test Level / Note
Conducted BS EN/EN55032 (CISPR32) Class B
Radiated BS EN/EN55032 (CISPR32) Class A
Harmonic Current BS EN/EN61000-3-2 Class A
Voltage Flicker BS EN/EN61000-3-3 —–
EMC IMMUNITY BS EN/EN61000-6-2
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 3
EFT / Burst BS EN/EN61000-4-4 Level 3
Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth
Conducted BS EN/EN61000-4-6 Level 3
Magnetic Field BS EN/EN61000-4-8 Level 4
Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS MTBF 597.3K hrs min.     Telcordia SR-332 (Bellcore) ; 63.3K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 290*140*41mm (L*W*H)
PACKING 2.51kg ; 6pcs/16.06kg/0.91CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.  Tolerance :includes set up tolerance, line regulation and load regulation.
4.  Derating may be needed under low input voltages. Please check the derating curve for more details.
5.  The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
6.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
7.  Refer to derating curve.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

SPECIFICATION (Blank/PM/CAN type)

MODEL UHP-1500-115 UHP-1500-230 UHP-1500-380
OUTPUT DC VOLTAGE (DEFAULT) 115V 230V 380V
CURRENT (FACTORY DEFAULT) 13.05A 6.52A 3.95A
RATED CURRENT (Max.) 13.05A 6.95A 4.5A
POWER (FACTORY DEFAULT) 1500.75W 1500W 1500W
RATED POWER (Max.)(Note.9) 1500.75W 1501.2W 1503W
RIPPLE & NOISE (Max.) Note.2 1150mVp-p 2300mVp-p 3800mVp-p
FULL POWER VOLTAGE RANGE 115~138V 216~260V 334~400V
VOLTAGE ADJ. RANGE By built-in potentiometer, SVR
90~138V 170~260V 260~400V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC at 75% load      10ms/230VAC at full load
INPUT VOLTAGE RANGE         Note.4 90 ~ 264VAC        250 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF≥0.95/230VAC  at full load
EFFICIENCY (Typ.) 95% 95% 95.5%
AC CURRENT (Typ.) 8A/230VAC
INRUSH CURRENT (Typ.) Cold start 60A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
PROTECTION OVER LOAD 105~125% rated output power
Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.
SHORT CIRCUIT Constant current limiting, unit will shutdown after 5 sec, re-power on to recover.
OVER VOLTAGE 145 ~175V 273 ~ 325V 420 ~ 460V
Protection type :Shut down O/P voltage,re-power on to recover
OVER TEMPERATURE Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION OUTPUT VOLTAGE PROGRAMMABLE(PV) Note 5 Adjustment of output voltage is allowable to 50 ~ 120% of nominal output voltage Please refer to the Function Manual.
OUTPUT CURRENT PROGRAMMABLE(PC) Note 5 Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
REMOTE ON/OFF CONTROL Power ON : Short circuit  Power OFF : Open circuit
AUXILIARY POWER 12V @ 0.4A tolerance ±10%, ripple=150mVp-p
DC-OK SIGNAL The TTL signal out, PSU turn on = 4.4 ~ 5.5V ; PSU turn off = -0.5 ~ 0.5V. Please refer to the Function Manual.
ENVIRONMENT WORKING TEMP. -30 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.6) SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE Note 8 OVC Ⅲ I/P-O/P:6KVDC  I/P-FG:4KVDC   O/P-FG:4KVDC
ISOLATION RESISTANCE Note 8 I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
EMC EMISSION Parameter Standard Test Level / Note
Conducted BS EN/EN55032 (CISPR32) Class B
Radiated BS EN/EN55032 (CISPR32) Class A
Harmonic Current BS EN/EN61000-3-2 Class A
Voltage Flicker BS EN/EN61000-3-3 —–
EMC IMMUNITY BS EN/EN61000-6-2
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 3
EFT / Burst BS EN/EN61000-4-4 Level 3
Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth
Conducted BS EN/EN61000-4-6 Level 3
Magnetic Field BS EN/EN61000-4-8 Level 4
Voltage Dips and Interruptions BS EN/EN61000-4-11 95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
OTHERS MTBF 597.3K hrs min.  Telcordia SR-332 (Bellcore) ; 63.3K hrs min.   MIL-HDBK-217F (25℃)
DIMENSION 290*140*41mm (L*W*H)
PACKING 2.51kg ; 6pcs/16.06kg/0.91CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance :includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. PV/PC functions when users do not use SVR.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
8. Refer to derating curve.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

BLOCK DIAGRAM

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - BLOCK DIAGRAM

STATIC CHARACTERISTIC

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - STATIC CHARACTERISTIC

EFFICIENCY VS LOAD (380V MODEL)

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - EFFICIENCY VS LOAD

DERATING CURVE

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - DERATING CURVE

FUNCTION MANUAL ( For E type)

  1. Output VoltageMEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - FUNCTION MANUAL
  2. Remote ON-OFF Control
    The power supply can be turned ON/OFF individually or along with other units in parallel by using the “Remote ON-OFF” function.

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Remote

Remote ON-OFF Power Supply Status
Short circuit ON
Open circuit OFF

FUNCTION MANUAL (Blank/PM/CAN type)

  1. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
    ※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 50%~120% by applying EXTERNAL VOLTAGE.
    ※ When PC/PV are used at the same time, PC is preferredMEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - FUNCTION MANUAL 1
  2. Constant Current Programming (or, PC / remote current programming / dynamic current trim)
    ※ The output current can be trimmed to 20~100% of the rated current by applying EXTERNAL VOLTAGE.
    In PC mode, the output current shall meet the output voltage / output current reduction curve.MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Constant Current 1◎ Covered by over temperature protection auto de-rating function works under operation either in PC mode or under control by communication protocol.
    T1(Typ.): Maximum ambient temperature of full load.
    T2(Typ.): T1+5.℃MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Constant Current 2
  3. Remote ON-OFF Control
    The power supply can be turned ON/OFF individually or along with other units in parallel by using the “Remote ON-OFF” function.MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Constant Current 3
    Remote ON-OFF Power Supply Status
    Short circuit ON
    Open circuit OFF
  4. DC-OK Signal
    DC-OK signal is a TTL level signal. The maximum sink current is 10mA and the maximum external voltage is 5.6V.MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Constant Current 4
    DC-OK signal Power Supply Status
    “High” >4.4~5.5V ON
    “Low” <-0.5~0.5V OFF
  5. PMBus Communication Interface
    UHP-1500 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring, output trimming, etc. For details, please refer to the Function Manual.

MECHANICAL SPECIFICATION (For E type)

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - MECHANICAL SPECIFICATION

AC Input Terminal(TB1) Pin NO. Assignment

Pin No. Assignment Terminal Max mounting torque
1 AC/L DG58S 18Kgf-cm
2 AC/N
3 SP Tools Digital Multimeter Electrical SP62012 - Earth ground

DC Output Terminal(TB2,TB3) Pin NO. Assignment

Pin No. Assignment Terminal Max mounting torque
TB2 +V (MW) HS455A 8Kgf-cm
TB3 -V

※Control Pin No. Assignment(CN82) : HRS DF11-04DP-2DS or equivalent

Pin No. Function Description
1,2 Remote ON-OFF The unit can turn the output ON/OFF by dry contact between Remote ON/OFF and GND
3,4 GND

MECHANICAL SPECIFICATION (Blank/PM/CAN type)

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - MECHANICAL SPECIFICATION 2

AC Input Terminal(TB1) Pin NO. Assignment

Pin No. Assignment Terminal Max mounting torque
1 AC/L DG58S 18Kgf-cm
2 AC/N
3 SP Tools Digital Multimeter Electrical SP62012 - Earth ground

DC Output Terminal(TB2,TB3) Pin NO. Assignment

Pin No. Assignment Terminal Max mounting torque
TB2 +V (MW) HS455A 8Kgf-cm
TB3 -V

※DIP SW:

Pin No. Function Description
1 A0 PMBus / CANBus interface address switch.
2 A1
3 A2

※Control Pin No. Assignment(CN71) : HRS DF11-04DP-2DS or equivalent

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Mating Housing 1

Mating Housing HRS DF11-04DS or equivalent
Terminal HRS DF11-**SC or equivalent

※Control Pin No. Assignment(CN77) : HRS DF11-08DP-2DS or equivalent

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - Mating Housing 2

Mating Housing HRS DF11-08DS or equivalent
Terminal HRS DF11-**SC or equivalent

※Control Pin No. Assignment(CN77) : HRS DF11-04DP-2DS or equivalent

Pin No. Function Description
1 PV Connection for output voltage programming.(Note1)
2 PC Connection for constant current level programming.(Note.1)
3,4 GND (Signal) Negative output voltage signal.

※Control Pin No. Assignment(CN77) : HRS DF11-04DP-2DS or equivalent

Pin No. Function Description
1,2 +12V-AUX Auxiliary voltage output, 10.8~13.2V, referenced to GND-AUX (pin3 & 4).
The maximum load current is 0.4A. This output is not controlled by “Remote ON-OFF”.
3.4 GND-AUX Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
5 Remote ON-OFF The unit can turn the output  ON/OFF by dry contact  between Remote ON/OFF and  12-AUX.(Note.2) Short (10.8 ~ 13.2V) : Power ON ; Open(-0.5 ~ 0.5V) : Power OFF ; The maximum input voltage is 13.2V
6 DC-OK Low (-0.5 ~ 0.5V) : When the Vout≦77%±6%. High (4.5 ~ 5.5V) : When Vout≧80%±6%.
The maximum sourcing current is 10mA and only for output.(Note.2)
7 SCL For PMBus model: Serial Clock used in the PMBus interface. (Note.2)
CANH For CANBus model: Data line used in CANBus interface. (Note.2)
8 SDA For PMBus model: Serial Data used in the PMBus interface. (Note.2)
CANL For CANBus model: Data line used in CANBus interface. (Note.2)

Note1: Non-isolated signal, referenced to [GND(signal)].
Note2: Isolated signal, referenced to GND-AUX.

INSTALLATION

  1. Operate with additional aluminum plate
    In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-1500-HV series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-1500-HV series must be firmly mounted at the center of the aluminum plate.MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - aluminum plate
  2. With 40 CFM forced air

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series - forced air

MEAN WELL logo

Documents / Resources

MEAN WELL UHP-1500-HV 1500W Conduction Cooling with High Voltage Output series [pdf] Installation Guide
UHP-1500-HV 1500W Conduction Cooling with High Voltage Output, UHP-1500-HV, 1500W Conduction Cooling with High Voltage Output, Cooling with High Voltage Output, High Voltage Output, Voltage Output, Output