500W Single Output DC-DC Converter
SD-500 series
Features:
- DC input active surge current limiting
- Wide 4:1~2:1 DC input range (24V: 19~72VDC, 96V:72~144VDC)
- Protections: Short circuit / Overload / Over voltage / Over temperature / Input polarity(by fuse)
- 2000VAC I/O Isolation
- Forced air cooling by built-in DC fan with fan speed control function
- Output OK Signal
- Built-in remote ON-OFF control
- Built-in remote sense function
- 3 years warranty
https://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf
GTIN CODE
MW Search https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | SD-500L-12 | SD-500L-24 | SD-500L-48 | SD-500H-12 | SD-500H-24 | SD-500H-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 48V | 12V | 24V | 48V |
RATED CURRENT | 40A | 21A | 10.5A | 40A | 21A | 10.5A | |
CURRENT RANGE | 0 ~ 40A | 0 ~ 21A | 0 ~ 10.5A | 0 ~ 40A | 0 ~ 21A | 0 ~ 10.5A | |
RATED POWER | 480W | 504W | 504W | 480W | 504W | 504W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 11 ~ 15V | 23 ~ 30V | 46 ~ 60V | 11 ~ 15V | 23 ~ 30V | 46 ~ 60V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 50ms at full load | ||||||
INPUT | VOLTAGE RANGE Note.5 | 19 ~ 72VDC | 72 ~ 144VDC | ||||
EFFICIENCY (Typ.) | 86% | 88% | 89% | 87% | 89% | 90% | |
DC CURRENT (Typ.) | 24.2A/19VDC 24.8A/24VDC 12A/48VDC | 8A/72VDC 6A/96VDC | |||||
CURRENT (AT NO LOAD) | Max. 0.2A/48VDC | Max. 0.1A/96VDC | |||||
INRUSH CURRENT (Typ.) | 60A/48VDC | 60A/96VDC | |||||
PROTECTION | OVERLOAD | 105 ~ 125% rated output power | |||||
Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover | |||||||
OVER VOLTAGE | 16 ~ 19V | 30.8 ~ 35.2V | 62 ~ 68V | 16 ~ 19V | 30.8 ~ 35.2V | 62 ~ 68V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
FUNCTION | REMOTE ON/OFF CONTROL | Please refer to function manual | |||||
OUTPUT OK SIGNAL | Open collector signal low when PSU turns on, max. sink current :10mA | ||||||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.02%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | IEC62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1 | |||||
WITHSTAND VOLTAGE | I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020 | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||
OTHERS | MTBF | 1333.7K hrs min. Telcordia SR-332 (Bellcore) ; 196.3K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 215*115*50mm (L*W*H) | ||||||
PACKING | 1.15Kg; 12pcs/14.8Kg/0.9CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
DC Input Terminal Pin No. Assignment
Pin No. | Assignment | Pin No. | Assignment |
1 | DC INPUT V+ | 4,5 | -V |
2 | DC INPUT V- | 6,7 | +V |
3 | FG |
Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent
Pin No. | Assignment | Pin No. | Assignment | Mating Housing | Terminal |
1 | +S | 4 | GND | HRS DF11-6DS or equivalent | JST SPHD-002T-P0.5 or equivalent |
2 | -S | 5 | RC | ||
3 | OUTPUT OK | 6 | RCG |
Block Diagram
Derating Curve
Static Characteristics
Function Description of CN3
Pin No. | Function | Description |
1 | +S | Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. |
2 | -S | Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. |
3 | O/P OK | Open collector signal, reference to pin4(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum external voltage is 13V. |
4 | GND | These pins connect to the negative terminal (-V). |
5 | RC | Remote ON/OFF |
6 | RCG | Remote ON/OFF ground |
Function Manual
- Remote ON/OFF
(1)Remote ON/OFF control becomes available by applying voltage in CN3
(2)Table 1.1 shows the specification of Remote ON/OFF function
(3)Fig.1.2 shows the example to connect Remote ON/OFF control function
Table 1.1 Specification of Remote ON/OFFConnection Method Fig. 1.2(A) Fig. 1.2(B) Output on SW Open V=0~0.8Vdc Output off SW Close V=4~10Vdc Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source(B)Using external voltage source
- Output OK signal
“Output OK” is an open collector signal.
It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external signalthe other is sending out a voltage signal.
2-1 Sink current :
The maximum sink current is 10mA and the maximum external voltage is 13V.
2-2 Voltage signal :Between O/P OK(pin3) and GND(pin4) Output Status 0 ~ 0.5V ON 12 ~ 13V OFF - Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.5V.