MEAN WELL Logo500W Single Output DC-DC Converter
SD-500 seriesMEAN WELL SD-500 series Single Output DC DC Converter

Features:

  • DC input active surge current limiting
  • Wide 4:1~2:1 DC input range (24V: 19~72VDC, 96V:72~144VDC)
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Input polarity(by fuse)
  • 2000VAC I/O Isolation
  • Forced air cooling by built-in DC fan with fan speed control function
  • Output OK Signal
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • 3 years warranty

MEAN WELL SD-500 series Single Output DC DC Converter - QR Codhttps://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf

GTIN CODE

MW Search https://www.meanwell.com/serviceGTIN.aspx

MEAN WELL SD-500 series Single Output DC DC Converter - SymbolSPECIFICATION

MODEL SD-500L-12 SD-500L-24 SD-500L-48 SD-500H-12 SD-500H-24 SD-500H-48
OUTPUT DC VOLTAGE 12V 24V 48V 12V 24V 48V
RATED CURRENT 40A 21A 10.5A 40A 21A 10.5A
CURRENT RANGE 0 ~ 40A 0 ~ 21A 0 ~ 10.5A 0 ~ 40A 0 ~ 21A 0 ~ 10.5A
RATED POWER 480W 504W 504W 480W 504W 504W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 11 ~ 15V 23 ~ 30V 46 ~ 60V 11 ~ 15V 23 ~ 30V 46 ~ 60V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 500ms, 50ms at full load
INPUT VOLTAGE RANGE         Note.5 19 ~ 72VDC 72 ~ 144VDC
EFFICIENCY (Typ.) 86% 88% 89% 87% 89% 90%
DC CURRENT (Typ.) 24.2A/19VDC  24.8A/24VDC  12A/48VDC 8A/72VDC  6A/96VDC
CURRENT (AT NO LOAD) Max. 0.2A/48VDC Max. 0.1A/96VDC
INRUSH CURRENT (Typ.) 60A/48VDC 60A/96VDC
PROTECTION OVERLOAD 105 ~ 125% rated output power
Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover
OVER VOLTAGE 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION REMOTE ON/OFF CONTROL Please refer to function manual
OUTPUT OK SIGNAL Open collector signal low when PSU turns on, max. sink current :10mA
ENVIRONMENT WORKING TEMP. -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.02%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS IEC62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-O/P:2KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS MTBF 1333.7K hrs min.     Telcordia SR-332 (Bellcore) ; 196.3K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION 215*115*50mm (L*W*H)
PACKING 1.15Kg; 12pcs/14.8Kg/0.9CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL SD-500 series Single Output DC DC Converter - Mechanical SpecificationDC Input Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 DC INPUT V+ 4,5 -V
2 DC INPUT V- 6,7 +V
3 FG

Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent

Pin No. Assignment Pin No. Assignment Mating Housing Terminal
1 +S 4 GND HRS DF11-6DS or equivalent JST SPHD-002T-P0.5 or equivalent
2 -S 5 RC
3 OUTPUT OK 6 RCG

Block Diagram

MEAN WELL SD-500 series Single Output DC DC Converter - Block Diagram

Derating Curve

MEAN WELL SD-500 series Single Output DC DC Converter - Derating Curve

Static Characteristics

MEAN WELL SD-500 series Single Output DC DC Converter - Static Characteristics

Function Description of CN3

Pin No. Function Description
1 +S Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
3 O/P OK Open collector signal, reference to pin4(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum external voltage is 13V.
4 GND These pins connect to the negative terminal (-V).
5 RC Remote ON/OFF
6 RCG Remote ON/OFF ground

Function Manual

  1. Remote ON/OFF
    (1)Remote ON/OFF control becomes available by applying voltage in CN3
    (2)Table 1.1 shows the specification of Remote ON/OFF function
    (3)Fig.1.2 shows the example to connect Remote ON/OFF control function
    Table 1.1 Specification of Remote ON/OFF
    Connection Method Fig. 1.2(A) Fig. 1.2(B)
    Output on SW Open V=0~0.8Vdc
    Output off SW Close V=4~10Vdc

    Fig.1.2 Examples of connecting remote ON/OFF
    (A)Using external voltage sourceMEAN WELL SD-500 series Single Output DC DC Converter - voltage(B)Using external voltage sourceMEAN WELL SD-500 series Single Output DC DC Converter - voltage 1

  2. Output OK signal
    “Output OK” is an open collector signal.
    It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external signalthe other is sending out a voltage signal.
    2-1 Sink current :
    The maximum sink current is 10mA and the maximum external voltage is 13V.
    2-2 Voltage signal :
    Between O/P OK(pin3) and GND(pin4) Output Status
    0 ~ 0.5V ON
    12 ~ 13V OFF

    MEAN WELL SD-500 series Single Output DC DC Converter - Voltage signal

  3. Remote Sense
    The remote sensing compensates voltage drop on the load wiring up to 0.5V.

MEAN WELL SD-500 series Single Output DC DC Converter - pairs

MEAN WELL LogoFile Name:SD-500-SPEC 2024-02-23
Downloaded from Arrow.com.

Documents / Resources

MEAN WELL SD-500 series Single Output DC DC Converter [pdf] Owner's Manual
SD-500L-12, SD-500L-24, SD-500L-48, SD-500H-12, SD-500H-24, SD-500H-48, SD-500 series Single Output DC DC Converter, SD-500 series, Single Output DC DC Converter, Output DC DC Converter, DC Converter, Converter

References

Leave a comment

Your email address will not be published. Required fields are marked *