MEAN WELL logo

200W Single Output DC-DC Converter
SD – 200 series

MEAN WELL SD-200 Series 200W Single Output DC DC Converter

Features

  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • 1500VAC I/O isolation
  • Cooling by free air convection
  • 100% full load burn-in test
  • 24V and 48V input voltage design refer to LVD
  • 2 years warranty

MEAN WELL SD-200 Series 200W Single Output DC DC Converter - qr code 1

https://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf

■ GTIN CODE
MW Search• https://www.meanwell.com/serviceGTIN.aspx

MEAN WELL SD-200 Series 200W Single Output DC DC Converter - symbol 1

(for SD-200C-5/12/24 type only)
MEAN WELL SD-200 Series 200W Single Output DC DC Converter - symbol 2

SPECIFICATION

MODEL SD-200B SD-200C
OUTPUT DC VOLTAGE 5V 12V 24V 48V 5V 12V 24V 48V
RATED CURRENT 34A 16.7A 8.4A 4.2A 40A 16.7A 8.4A 4.2A
CURRENT RANGE 0 ~ 34A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 40A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A
RATED POWER 170W 200.4W 201.6W 201.6W 200W 200.4W 201.6W 201.6W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p 200mVp-p 100mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5VDC 11 ~ 16VDC 23 ~ 30VDC 43 ~ 53VDC 4.5 ~ 5.5VDC 11 ~ 16VDC 23 ~ 30VDC 43 ~ 53VDC
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 300ms, 50ms at full load
INPUT VOLTAGE RANGE B:19 ~ 36VDC         C:36 ~ 72VDC         D:72 ~144VDC
EFFICIENCY (Typ.) 79% 82% 85% 86% 81% 84% 86% 86%
DC CURRENT (Typ.) 10.8A/24V 10.6A/24V 10.4A/24V 10.4A/24V 5.4A/48V 5.2A/48V 6.7A/48V 5A/48V
INRUSH CURRENT (Typ.) C:45A/48VDC         D:45A/96VDC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE 5.75 ~ 6.75V 16.8 ~ 20V 31.5 ~ 37.5V 53 ~ 65V 5.75 ~ 6.75V 16.8 ~ 20V 31.5 ~ 37.5V 53 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT WORKING TEMP. -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS UL62368-1approved (for SD-200C-5/12/24 type only), EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,6,8, light industry level, EAC TP TC 020
OTHERS MTBF 1919.7K hrs min.     Telcordia SR-332 (Bellcore) ; 280.6K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 215*115*50mm (L*W*H)
PACKING 1.1Kg; 12pcs/14.4Kg/0.9CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.  Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MEAN WELL logo

200W Single Output DC-DC Converter
SD – 200 series

MEAN WELL SD-200 Series 200W Single Output DC DC Converter

Features

  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • 1500VAC I/O isolation
  • Cooling by free air convection
  • 100% full load burn-in test
  • 24V and 48V input voltage design refer to LVD
  • 2 years warranty

MEAN WELL SD-200 Series 200W Single Output DC DC Converter - symbol 3

SPECIFICATION

MODEL SD-200D
OUTPUT DC VOLTAGE 5V 12V 24V 48V
RATED CURRENT 40A 16.7A 8.4A 4.2A
CURRENT RANGE 0 ~ 40A 0 ~ 16.7A 0 ~ 8.4A 0 ~ 4.2A
RATED POWER 200W 200.4W 201.6W 201.6W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5VDC 11 ~ 16VDC 23 ~ 30VDC 43 ~ 53VDC
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 300ms, 50ms at full load
INPUT VOLTAGE RANGE B:19 ~ 36VDC         C:36 ~ 72VDC         D:72 ~144VDC
EFFICIENCY (Typ.) 82% 82% 84% 90%
DC CURRENT (Typ.) 3.5A/96V 3.5A/96V 3.5A/96V 3.5A/96V
INRUSH CURRENT (Typ.) C:45A/48VDC         D:45A/96VDC
PROTECTION OVERLOAD 105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE 5.75 ~ 6.75V 16.8 ~ 20V 31.5 ~ 37.5V 53 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
 

ENVIRONMENT

WORKING TEMP. -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS IEC/BS EN/EN 62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55022 (CISPR22) Class B, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,6,8, light industry level, EAC TP TC 020
OTHERS MTBF 1919.7K hrs min.     Telcordia SR-332 (Bellcore) ; 280.6K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 215*115*50mm (L*W*H)
PACKING 1.1Kg; 12pcs/14.4Kg/0.9CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.  Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MEAN WELL logo

File Name:SD-200-SPEC 2022-02-28

Documents / Resources

MEAN WELL SD-200 Series 200W Single Output DC DC Converter [pdf] Owner's Manual
SD-200 Series 200W Single Output DC DC Converter, SD-200 Series, 200W Single Output DC DC Converter, Single Output DC DC Converter, Output DC DC Converter, DC Converter, Converter
MEAN WELL SD-200 Series 200W Single Output DC-DC Converter [pdf] Owner's Manual
SD-200 Series 200W Single Output DC-DC Converter, SD-200 Series, 200W Single Output DC-DC Converter, Single Output DC-DC Converter, Output DC-DC Converter, DC-DC Converter, DC Converter, Converter

References

Leave a comment

Your email address will not be published. Required fields are marked *