MEAN-WELL-LOGO

MEAN WELL RT-65 Series 65W Triple Output Switching Power Supply

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-PRODUCT

Product Usage Instructions

Installation:

  • Ensure the power supply is compatible with your device’s requirements.
  • Connect the input terminals to a suitable power source.
  • Connect the output terminals to your device following the provided specifications.

Operation:

  • Turn on the power supply using the power switch or by connecting it to the power source.
  • Monitor the LED indicator to ensure power is on.

Safety Precautions:

  • Do not operate the power supply in wet conditions to avoid electric shock.
  • Avoid overloading the power supply beyond its rated capacity.
  • If any abnormalities occur during operation, disconnect the power supply immediately.

FAQ

Frequently Asked Questions

  • Q: What should I do if the LED indicator does not light up?
    • A: Check the power source and connections to ensure proper installation. If the issue persists, contact customer support for assistance.
  • Q: How can I determine the appropriate output voltage for my device?
    • A: Refer to the specifications provided in the user manual and select the output voltage that matches your device’s requirements.
  • Q: Can I use this power supply for outdoor applications?
    • A: It is recommended to use the power supply in indoor environments to prevent damage from external elements.

Features

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300 VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-2

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL RT-65A RT-65B RT-65C RT-65D
 

 

 

 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V 5V 24V 12V
RATED CURRENT 6A 2.8A 0.5A 5A 2.8A 0.5A 5A 2.2A 0.5A 4A 1.5A 1A
CURRENT RANGE            Note.6 0 ~ 8A 0 ~ 3.5A 0 ~ 1A 0 ~ 8A 0 ~ 3.5A 0 ~ 1A 0 ~ 8A 0 ~ 3A 0 ~ 1A 0 ~ 8A 0 ~ 2A 0 ~ 1A
RATED POWER                 Note.6 66.1W 64.6W 65.5W 68W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 120mVp-p 80mVp-p 80mVp-p 150mVp-p 120mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±6.0% ±5.0% ±2.0% ±6.0% ±5.0% ±2.0% +8,-4% ±5.0% ±2.0% +4,-10% ±6.0%
LINE REGULATION           Note.4 ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±0.5% ±0.5% ±1.5% ±2.0%
LOAD REGULATION         Note.5 ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±1.0% ±1.0% ±3.0% ±4.0%
SETUP, RISE TIME 500ms, 20ms/230VAC            1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC            14ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE 88 ~ 264VAC           125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 76% 76% 77% 78%
AC CURRENT (Typ.) 2A/115VAC           1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

PROTECTION

 

OVERLOAD

110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

OVER VOLTAGE

CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/IEC 60950-1:2005, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 2720.8K hrs min.       Telcordia SR-332 (Bellcore) ;507.6K hrs min.        MIL-HDBK-217F (25℃)
DIMENSION 129*98*38mm (L*W*H)
PACKING 0.44Kg; 30pcs/13.2Kg/0.72CUFT
 

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
    (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-3

Case No. 903 Unit:mm

Terminal Pin No. Assignment

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-7

Block Diagram

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-4

Derating Curve

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-5

Output Derating VS Input Voltage

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-6

User’s Manual

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-1

MEAN-WELL-RT-65-Series-65W-Triple-Output-Switching-Power-Supply-FIG-2

Documents / Resources

MEAN WELL RT-65 Series 65W Triple Output Switching Power Supply [pdf] Owner's Manual
RT-65A, RT-65B, RT-65C, RT-65D, RT-65 Series 65W Triple Output Switching Power Supply, RT-65 Series, 65W Triple Output Switching Power Supply, Triple Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply

References