MEAN WELL RT-65 Series 65W Triple Output Switching Power Supply
Product Usage Instructions
Installation:
- Ensure the power supply is compatible with your device’s requirements.
- Connect the input terminals to a suitable power source.
- Connect the output terminals to your device following the provided specifications.
Operation:
- Turn on the power supply using the power switch or by connecting it to the power source.
- Monitor the LED indicator to ensure power is on.
Safety Precautions:
- Do not operate the power supply in wet conditions to avoid electric shock.
- Avoid overloading the power supply beyond its rated capacity.
- If any abnormalities occur during operation, disconnect the power supply immediately.
FAQ
Frequently Asked Questions
- Q: What should I do if the LED indicator does not light up?
- A: Check the power source and connections to ensure proper installation. If the issue persists, contact customer support for assistance.
- Q: How can I determine the appropriate output voltage for my device?
- A: Refer to the specifications provided in the user manual and select the output voltage that matches your device’s requirements.
- Q: Can I use this power supply for outdoor applications?
- A: It is recommended to use the power supply in indoor environments to prevent damage from external elements.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105°C long life electrolytic capacitors
- Withstand 300 VAC surge input for 5 second
- High operating temperature up to 70°C
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- 3 years warranty
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL | RT-65A | RT-65B | RT-65C | RT-65D | |||||||||
OUTPUT |
OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 24V | 12V | |
RATED CURRENT | 6A | 2.8A | 0.5A | 5A | 2.8A | 0.5A | 5A | 2.2A | 0.5A | 4A | 1.5A | 1A | |
CURRENT RANGE Note.6 | 0 ~ 8A | 0 ~ 3.5A | 0 ~ 1A | 0 ~ 8A | 0 ~ 3.5A | 0 ~ 1A | 0 ~ 8A | 0 ~ 3A | 0 ~ 1A | 0 ~ 8A | 0 ~ 2A | 0 ~ 1A | |
RATED POWER Note.6 | 66.1W | 64.6W | 65.5W | 68W | |||||||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 80mVp-p | 80mVp-p | 150mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | |||||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±5.0% | ±2.0% | ±6.0% | ±5.0% | ±2.0% | +8,-4% | ±5.0% | ±2.0% | +4,-10% | ±6.0% | |
LINE REGULATION Note.4 | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±0.5% | ±0.5% | ±1.5% | ±2.0% | |
LOAD REGULATION Note.5 | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±1.0% | ±1.0% | ±3.0% | ±4.0% | |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||||||||
HOLD UP TIME (Typ.) | 60ms/230VAC 14ms/115VAC at full load | ||||||||||||
INPUT |
VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
EFFICIENCY(Typ.) | 76% | 76% | 77% | 78% | |||||||||
AC CURRENT (Typ.) | 2A/115VAC 1.2A/230VAC | ||||||||||||
INRUSH CURRENT (Typ.) | COLD START 50A/230VAC | ||||||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||||||
PROTECTION |
OVERLOAD |
110 ~ 150% rated output power | |||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE |
CH1: 5.75 ~ 6.75V | ||||||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
ENVIRONMENT |
WORKING TEMP. | -25 ~ +70℃ (Refer to “Derating Curve”) | |||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃)on +5V output | ||||||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||||||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/IEC 60950-1:2005, EAC TP TC 004 approved | |||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 | ||||||||||||
OTHERS |
MTBF | 2720.8K hrs min. Telcordia SR-332 (Bellcore) ;507.6K hrs min. MIL-HDBK-217F (25℃) | |||||||||||
DIMENSION | 129*98*38mm (L*W*H) | ||||||||||||
PACKING | 0.44Kg; 30pcs/13.2Kg/0.72CUFT | ||||||||||||
NOTE |
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Case No. 903 Unit:mm
Terminal Pin No. Assignment
Block Diagram
Derating Curve
Output Derating VS Input Voltage
User’s Manual
Documents / Resources
![]() |
MEAN WELL RT-65 Series 65W Triple Output Switching Power Supply [pdf] Owner's Manual RT-65A, RT-65B, RT-65C, RT-65D, RT-65 Series 65W Triple Output Switching Power Supply, RT-65 Series, 65W Triple Output Switching Power Supply, Triple Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |