Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • High efficiency up to 91%
  • Forced air cooling by built-in DC fan
  • Output voltage programmable
  • Active current sharing up to 6000W (3+1)
  • Built-in remote ON-OFF control / remote sense /auxiliary power / power OK signal
  • Protections: Short circuit / Overload / Over voltage/ Over temperature
  • Optional conformal coating
  • 5 years warranty

Applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Burn-in facility
  • Digital broadcasting
  • RF application
  • GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description
RSP-1500 is a 1.5KW single output enclosed type AC/DC power supply. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan working for the temperature up to 70°C. Moreover, RSP-1500 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.

Model Encoding / Order Information

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-1

Specifications

MODEL RSP-1500-5 RSP-1500-12 RSP-1500-15 RSP-1500-24 RSP-1500-27 RSP-1500-48
 

 

 

 

 

 

 

OUTPUT

DC VOLTAGE 5V 12V 15V 24V 27V 48V
RATED CURRENT 240A 125A 100A 63A 56A 32A
CURRENT RANGE 0 ~ 240A 0 ~ 125A 0 ~ 100A 0 ~ 63A 0 ~ 56A 0 ~ 32A
RATED POWER 1200W 1500W 1500W 1512W 1512W 1536W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 10 ~ 13.5V 13.5 ~ 16.5V 20 ~ 26.4V 24 ~ 30V 43 ~ 56V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±2.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 1500ms, 100ms at full load
HOLD UP TIME (Typ.) 10ms at full load 14ms at full load 16ms at full load
 

 

 

 

INPUT

VOLTAGE RANGE 90 ~ 264VAC         127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) 0.95/230VAC          0.98/115VAC at full load
EFFICIENCY (Typ.) 80% 87% 87% 90% 90% 91%
AC CURRENT (Typ.) 17A/115VAC         8A/230VAC
INRUSH CURRENT (Typ.) 30A/115VAC          60A/230VAC
LEAKAGE CURRENT <2.0mA / 240VAC
 

 

 

PROTECTION

 

OVERLOAD                                        Note.4

105 ~135% rated output power
Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover
 

OVER VOLTAGE

5.75 ~ 6.75V 13.8 ~ 16.8V 17 ~ 20.5V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down
 

 

 

FUNCTION

OUTPUT VOLTAGE PROGRAMMABLE(PV) Adjustment of output voltage is allowable to 70 ~ 100% of nominal output voltage. Please refer to the Function Manual.
CURRENT SHARING Up to 6000W or (3+1) units. Please refer to the Function Manual.
AUXILIARY POWER 12V@0.1A(Only for Remote ON-OFF control)
REMOTE ON-OFF CONTROL Please see the Function Manual.
REMOTE SENSE Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual.
ALARM SIGNAL OUTPUT Power OK signal. Please see the Function Manual.
 

 

 

ENVIRONMENT

WORKING TEMP. -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT ±0.05%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
 

 

 

 

 

 

 

 

 

SAFETY & EMC

(Note 5)

SAFETY STANDARDS UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
 

 

 

EMC EMISSION

Parameter Standard Test Level / Note
Conducted BS EN/EN55032 (CISPR32), BSMI CNS15936 Class B/Class A (only for BSMI)
Radiated BS EN/EN55032 (CISPR32), BSMI CNS15936 Class A
Harmonic Current BS EN/EN61000-3-2 —–
Voltage Flicker BS EN/EN61000-3-3 —–
 

 

 

 

 

 

EMC IMMUNITY

BS EN/EN55035, BS EN/EN61000-6-2
Parameter Standard Test Level / Note
ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 3
EFT / Burst BS EN/EN61000-4-4 Level 2
Surge BS EN/EN61000-4-5 Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line
Conducted BS EN/EN61000-4-6 Level 3
Magnetic Field BS EN/EN61000-4-8 Level 4
Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods

 

OTHERS

MTBF 814.4K hrs min.      Telcordia SR-332 (Bellcore) ; 90.4K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION 278*127*83.5mm (L*W*H)
PACKING 3.0Kg; 4pcs/13Kg/1.19CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Derating may be needed under low input voltages. Please check the derating curve for more details.

5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-2

Static Characteristics

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-3

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-4

Function Manual

  1. Remote Sense
    The Remote Sense compensates voltage drop on the load wiring up to 0.3V.MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-5
  2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
    In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 70~100%(Typ.) of the nominal voltage by applying
    EXTERNAL RESISTANCEMEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-6Connect an external resistor between & on CN1 or CN2, and +S & +V, -S & -V also need to be connected. TRIM(pin4) -S(pin3 or pin4 or pin5)MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-7
  3. Remote ON-OFF
    Remote ON-OFF is activated by the configuration with respect to CN1,CN2 and CN3 as shown in the following diagram.MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-8MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-9
  4. Alarm Signal Output
    Alarm signal is sent out through “P OK ” & ” P OK GND” and pins on CN3. Please acknowledge an external voltage source is required for this f P OK P OK GND unction.MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-10MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-11
  5. Current Sharing with Remote Sense
    • RSP-1500 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below
    • Difference of output voltages among parallel units should be less than 0.2V.
    • The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
    • The total output current must not exceed the value determined by the following equation:
    • Maximum output current at parallel operation=(Rated current per unit) (Number of unit) 0.9.MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-12

Mechanical Specification

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-13

Mounting Instruction

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-14

CN1 and CN2 are connected internally.

Pin No. Function Description
1 RCG Remote ON-OFF Ground
2 RC2 Remote ON-OFF
3,5,7 -S Negative sensing for remote sense
4 TRIM Connection for output voltage programming
6 LS(Current Share) Current Share
8 +S Postive sensing for remote sense

Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-15

Pin No. Function Description
1 P OK GND Power OK Ground
2 P OK Power OK Signal
3 RCG Remote ON-OFF Ground
4 AUXG Auxiliary Ground
5 RC1 Remote ON-OFF
6 AUX Auxiliary Output

AC Input Terminal Pin No. Assignment

MEAN-WELL-RSP-1500-Series-Single-Output-Power-Supply-fig-16

Installation Manual
Please refer to: http://www.meanwell.com/manual.html

Documents / Resources

MEAN WELL RSP-1500 Series Single Output Power Supply [pdf] Owner's Manual
RSP-1500 Series Single Output Power Supply, RSP-1500 Series, Single Output Power Supply, Output Power Supply, Power Supply, Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *