MEAN WELL RSP-1500 Series Single Output Power Supply
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 91%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 6000W (3+1)
- Built-in remote ON-OFF control / remote sense /auxiliary power / power OK signal
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- Optional conformal coating
- 5 years warranty
Applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting
- RF application
- GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
RSP-1500 is a 1.5KW single output enclosed type AC/DC power supply. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan working for the temperature up to 70°C. Moreover, RSP-1500 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Model Encoding / Order Information
Specifications
MODEL | RSP-1500-5 | RSP-1500-12 | RSP-1500-15 | RSP-1500-24 | RSP-1500-27 | RSP-1500-48 | |
OUTPUT |
DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | 240A | 125A | 100A | 63A | 56A | 32A | |
CURRENT RANGE | 0 ~ 240A | 0 ~ 125A | 0 ~ 100A | 0 ~ 63A | 0 ~ 56A | 0 ~ 32A | |
RATED POWER | 1200W | 1500W | 1500W | 1512W | 1512W | 1536W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10 ~ 13.5V | 13.5 ~ 16.5V | 20 ~ 26.4V | 24 ~ 30V | 43 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 100ms at full load | ||||||
HOLD UP TIME (Typ.) | 10ms at full load | 14ms at full load | 16ms at full load | ||||
INPUT |
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | 0.95/230VAC 0.98/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 80% | 87% | 87% | 90% | 90% | 91% | |
AC CURRENT (Typ.) | 17A/115VAC 8A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 30A/115VAC 60A/230VAC | ||||||
LEAKAGE CURRENT | <2.0mA / 240VAC | ||||||
PROTECTION |
OVERLOAD Note.4 |
105 ~135% rated output power | |||||
Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover | |||||||
OVER VOLTAGE |
5.75 ~ 6.75V | 13.8 ~ 16.8V | 17 ~ 20.5V | 27.6 ~ 32.4V | 31 ~ 36.5V | 57.6 ~ 67.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
FUNCTION |
OUTPUT VOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltage is allowable to 70 ~ 100% of nominal output voltage. Please refer to the Function Manual. | |||||
CURRENT SHARING | Up to 6000W or (3+1) units. Please refer to the Function Manual. | ||||||
AUXILIARY POWER | 12V@0.1A(Only for Remote ON-OFF control) | ||||||
REMOTE ON-OFF CONTROL | Please see the Function Manual. | ||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual. | ||||||
ALARM SIGNAL OUTPUT | Power OK signal. Please see the Function Manual. | ||||||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032 (CISPR32), BSMI CNS15936 | Class B/Class A (only for BSMI) | |||||
Radiated | BS EN/EN55032 (CISPR32), BSMI CNS15936 | Class A | |||||
Harmonic Current | BS EN/EN61000-3-2 | —– | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2 | ||||||
Parameter | Standard | Test Level / Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||
EFT / Burst | BS EN/EN61000-4-4 | Level 2 | |||||
Surge | BS EN/EN61000-4-5 | Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||||
OTHERS |
MTBF | 814.4K hrs min. Telcordia SR-332 (Bellcore) ; 90.4K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 278*127*83.5mm (L*W*H) | ||||||
PACKING | 3.0Kg; 4pcs/13Kg/1.19CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Block Diagram
Static Characteristics
Function Manual
- Remote Sense
The Remote Sense compensates voltage drop on the load wiring up to 0.3V. - Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 70~100%(Typ.) of the nominal voltage by applying
EXTERNAL RESISTANCEConnect an external resistor between & on CN1 or CN2, and +S & +V, -S & -V also need to be connected. TRIM(pin4) -S(pin3 or pin4 or pin5)
- Remote ON-OFF
Remote ON-OFF is activated by the configuration with respect to CN1,CN2 and CN3 as shown in the following diagram. - Alarm Signal Output
Alarm signal is sent out through “P OK ” & ” P OK GND” and pins on CN3. Please acknowledge an external voltage source is required for this f P OK P OK GND unction. - Current Sharing with Remote Sense
- RSP-1500 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below
- Difference of output voltages among parallel units should be less than 0.2V.
- The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
- The total output current must not exceed the value determined by the following equation:
- Maximum output current at parallel operation=(Rated current per unit) (Number of unit) 0.9.
Mechanical Specification
Mounting Instruction
CN1 and CN2 are connected internally.
Pin No. | Function | Description |
1 | RCG | Remote ON-OFF Ground |
2 | RC2 | Remote ON-OFF |
3,5,7 | -S | Negative sensing for remote sense |
4 | TRIM | Connection for output voltage programming |
6 | LS(Current Share) | Current Share |
8 | +S | Postive sensing for remote sense |
Control Pin No. Assignment (CN3) : HRS DF11-6DP-2DS or equivalent
Pin No. | Function | Description |
1 | P OK GND | Power OK Ground |
2 | P OK | Power OK Signal |
3 | RCG | Remote ON-OFF Ground |
4 | AUXG | Auxiliary Ground |
5 | RC1 | Remote ON-OFF |
6 | AUX | Auxiliary Output |
AC Input Terminal Pin No. Assignment
Installation Manual
Please refer to: http://www.meanwell.com/manual.html