RSD-300 Series Railway Single Output DC DC Converter

Specifications:

  • Model: RSD-300 series
  • DC Voltage:
    • RSD-300B-5: 5V
    • RSD-300B-12: 12V
    • RSD-300B-24: 24V
    • RSD-300B-48: 48V
    • RSD-300C-5: 5V
    • RSD-300C-12: 12V
    • RSD-300C-24: 24V
    • RSD-300C-48: 48V
  • Rated Power: 210W
  • Input Voltage Range:
    • 16.8 ~ 31.2VDC
    • 14.4 ~ 33.6VDC
    • 33.6 ~ 62.4VDC
    • 28.8 ~ 67.2VDC
  • Efficiency:
    • 89% – 91.5%
  • Temperature Range: -40°C to +55°C
  • Dimensions: 216 x 96.5 x 40mm (L x W x H)

Product Usage Instructions:

Installation:

  1. Ensure input voltage matches the specified range for the
    model.
  2. Mount the converter in a well-ventilated area for proper
    cooling.
  3. Connect output leads to the intended device securely.

Operation:

  1. Turn on the input power source within the specified voltage
    range.
  2. Observe the LED indicator for power status.
  3. Monitor the device for any abnormal behavior during
    operation.

Maintenance:

  1. Regularly check for dust buildup and clean the converter if
    necessary.
  2. Inspect input and output connections for any signs of
    damage.
  3. Ensure proper ventilation around the converter for optimal
    performance.

FAQ:

Q: What should I do if the LED indicator does not light
up?

A: Check the input power source and connections to ensure proper
voltage and secure attachment.

Q: Can I operate the converter in high-temperature
environments?

A: The converter is designed to operate within the specified
temperature range. Operating outside this range may affect
performance.

Q: How can I test if the converter is functioning
correctly?

A: Connect a load within the rated current range and verify
output voltage stability under load.

“`

300W Railway Single Output DC-DC Converter

RSD-300 series

Features :
Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard

User’s Manual

2:1 wide input range

Protections: Short circuit / Overload / Over voltage / Over temperature / Input reverse polarity

4000VDC I/O isolation

Cooling by free air convection

Half encapsulated

Built-in constant current limiting circuit

1U low profile 40mm All using 105 long life electrolytic capacitors

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

LED indicator for power on 100% full load burn-in test 3 years warranty

UL62368-1 AS/NZS62368-1 TPTC004 IEC62368-1

MODEL

RSD-300B-5 RSD-300B-12 RSD-300B-24 RSD-300B-48 RSD-300C-5 RSD-300C-12 RSD-300C-24 RSD-300C-48

DC VOLTAGE

5V

12V

24V

48V

5V

12V

24V

48V

RATED CURRENT

42A

22.5A

11.3A

5.7A

42A

25A

12.5A

6.3A

CURRENT RANGE

0 ~ 42A

0 ~ 22.5A

0 ~ 11.3A

0 ~ 5.7A

0 ~ 42A

0 ~ 25A

0 ~ 12.5A

0 ~ 6.3A

OUTPUT

RATED POWER

210W

RIPPLE & NOISE (max.) Note.2 100mVp-p

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±1.0%

270W 120mVp-p ±2.0% ±0.3% ±1.0%

271.2W 150mVp-p ±2.0% ±0.2% ±1.0%

273.6W 180mVp-p ±2.0% ±0.5% ±1.0%

210W 100mVp-p ±2.0% ±0.5% ±1.0%

300W 120mVp-p ±2.0% ±0.3% ±1.0%

300W 150mVp-p ±2.0% ±0.2% ±1.0%

302.4W 180mVp-p ±2.0% ±0.5% ±1.0%

SETUP, RISE TIME HOLD UP TIME (Typ.)

800ms, 50ms at full load Please refer to page 5,6 Hold up Time( Load de-rating curve )

INPUT

VOLTAGE CONTINUOUS RANGE 1 SEC. EFFICIENCY (Typ.)
DC CURRENT (Typ.) INRUSH CURRENT (Typ.)

16.8 ~ 31.2VDC

14.4 ~ 33.6VDC

89%

89.5%

9.7A/24V

14.6A/24V

45A/24VDC

90% 14.6A/24V

91.5% 14.6A/24V

33.6 ~ 62.4VDC

28.8 ~ 67.2VDC

90.5%

91%

4.8A/48V

7.2A/48V

45A/48VDC

91.5% 7.2A/48V

92% 7.2A/48V

EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2017-Comply with S1 level

OVERLOAD

105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 5.75 ~ 7V Protection type : Shut down o/p voltage, re-power on to recover

13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V

OVER TEMPERATURE WORKING TEMP.

Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance

WORKING HUMIDITY ENVIRONMENT STORAGE TEMP.
TEMP. COEFFICIENT

5 ~ 95% RH non-condensing -40 ~ +85 ±0.03%/ (0 ~ 55)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373

OPERATING ALTITUDE 5000 meters

SAFETY STANDARDS

IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1

SAFETY &
EMC (Note 5)

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY

I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020

RAILWAY STANDARD

BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,BS EN/EN50121-3-2 for EMC;BS EN/EN45545-2 for fire protection

MTBF

1850.1K hrs min. Telcordia SR-332 (Bellcore) ; 130.8K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

216*96.5*40mm (L*W*H)

NOTE

PACKING

1.19Kg ; 12pcs/15.3Kg/0.97CUFT

1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-300-5 / -12)

5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on

a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to EMI testing of component power supplies.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

Features :
Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard

User’s Manual

2:1 wide input range

Protections: Short circuit / Overload / Over voltage / Over temperature / Input reverse polarity

4000VDC I/O isolation

Cooling by free air convection

Half encapsulated

Built-in constant current limiting circuit

1U low profile 40mm All using 105 long life electrolytic capacitors

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

LED indicator for power on 100% full load burn-in test 3 years warranty

UL62368-1 AS/NZS62368-1 TPTC004 IEC62368-1

MODEL

RSD-300D-5 RSD-300D-12 RSD-300D-24 RSD-300D-48 RSD-300E-5 RSD-300E-12 RSD-300E-24 RSD-300E-48

DC VOLTAGE

5V

12V

24V

48V

5V

12V

24V

48V

RATED CURRENT

42A

25A

12.5A

6.3A

42A

25A

12.5A

6.3A

CURRENT RANGE

0 ~ 42A

0 ~ 25A

0 ~ 12.5A

0 ~ 6.3A

0 ~ 42A

0 ~ 25A

0 ~ 12.5A

0 ~ 6.3A

OUTPUT

RATED POWER

210W

RIPPLE & NOISE (max.) Note.2 100mVp-p

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±1.0%

300W 120mVp-p ±2.0% ±0.2% ±1.0%

300W 150mVp-p ±2.0% ±0.2% ±1.0%

302.4W 180mVp-p ±2.0% ±0.5% ±1.0%

210W 100mVp-p ±2.0% ±0.5% ±1.0%

300W 120mVp-p ±2.0% ±0.3% ±1.0%

300W 150mVp-p ±2.0% ±0.2% ±1.0%

302.4W 180mVp-p ±2.0% ±0.5% ±1.0%

SETUP, RISE TIME HOLD UP TIME (Typ.)

800ms, 50ms at full load Please refer to page 5,6 Hold up Time( Load de-rating curve )

INPUT

VOLTAGE CONTINUOUS RANGE 1 SEC. EFFICIENCY (Typ.)
DC CURRENT (Typ.) INRUSH CURRENT (Typ.)

67.2 ~ 143VDC

57.6 ~ 154VDC

90%

91.5%

2.1A/110V 3.1A/110V

45A/110VDC

91.5% 3.1A/110V

91.5% 3.1A/110V

25.2 ~ 46.8VDC

21.6 ~ 50.4VDC

88%

90%

6.5A/36V

9.2A/36V

45A/36VDC

91% 9.2A/36V

91% 9.2A/36V

EN50155:2007-D-type and E-5 comply with S2 level @ full load; other E- type comply with S1 level @ full load, comply with S2 level @ 70% load INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2017-Comply with S1 level

OVERLOAD

105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

5.75 ~ 7V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 5.75 ~ 7V Protection type : Shut down o/p voltage, re-power on to recover

13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V

OVER TEMPERATURE WORKING TEMP.

Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance

WORKING HUMIDITY ENVIRONMENT STORAGE TEMP.
TEMP. COEFFICIENT

5 ~ 95% RH non-condensing -40 ~ +85 ±0.03%/ (0 ~ 55)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373

OPERATING ALTITUDE 5000 meters

SAFETY STANDARDS

IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1

SAFETY &
EMC (Note 5)

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY

I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020

RAILWAY STANDARD

BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC ; BS EN/EN45545-2 for fire protection

MTBF

1850.1K hrs min. Telcordia SR-332 (Bellcore) ; 130.8K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

216*96.5*40mm (L*W*H)

NOTE

PACKING

1.19Kg ; 12pcs/15.3Kg/0.97CUFT

1. All parameters NOT specially mentioned are measured at 36,110VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-300-5 / -12)

5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on

a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

Features :
Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
2:1 wide input range

User’s Manual

Protections: Short circuit / Overload / Over voltage / Over temperature / Input reverse polarity 4000VDC I/O isolation

Cooling by free air convection

Half encapsulated

Built-in constant current limiting circuit

GTIN CODE

·1U low profile 40mm ·All using 105 long life electrolytic capacitors
LED indicator for power on

MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION

100% full load burn-in test 3 years warranty

UL62368-1 AS/NZS62368-1 TPTC004 IEC62368-1

MODEL

RSD-300F-5

RSD-300F-12

RSD-300F-24

RSD-300F-48

DC VOLTAGE

5V

12V

24V

48V

RATED CURRENT

42A

25A

12.5A

6.3A

CURRENT RANGE

0 ~ 42A

0 ~ 25A

0 ~ 12.5A

0 ~ 6.3A

OUTPUT

RATED POWER

210W

RIPPLE & NOISE (max.) Note.2 100mVp-p

VOLTAGE TOLERANCE Note.3 ±2.0%

LINE REGULATION

±0.5%

LOAD REGULATION

±1.0%

300W 120mVp-p ±2.0% ±0.3% ±1.0%

300W 150mVp-p ±2.0% ±0.2% ±1.0%

302.4W 180mVp-p ±2.0% ±0.5% ±1.0%

SETUP, RISE TIME HOLD UP TIME (Typ.)

800ms, 50ms at full load Please refer to page 5,6 Hold up Time( Load de-rating curve )

INPUT

VOLTAGE CONTINUOUS RANGE 1 SEC. EFFICIENCY (Typ.)
DC CURRENT (Typ.) INRUSH CURRENT (Typ.)

50.4 ~ 93.6VDC 43.2 ~ 100.8VDC 89% 3.25A/72V 45A/72VDC

91% 4.6A/72V

91% 4.6A/72V

91.5% 4.6A/72V

EN50155:2007-F-type comply with S2 level @ full load INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2017-Comply with S1 level

OVERLOAD

105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed

PROTECTION OVER VOLTAGE

5.75 ~ 7V

13.8 ~ 16.2V

27.6 ~ 32.4V

Protection type : Shut down o/p voltage, re-power on to recover

55.2 ~ 64.8V

OVER TEMPERATURE WORKING TEMP.

Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance

WORKING HUMIDITY ENVIRONMENT STORAGE TEMP.
TEMP. COEFFICIENT

5 ~ 95% RH non-condensing -40 ~ +85 ±0.03%/ (0 ~ 55)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373

OPERATING ALTITUDE 5000 meters

SAFETY STANDARDS

IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1

SAFETY &
EMC (Note 5)

WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY

I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020

RAILWAY STANDARD

BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC ; BS EN/EN45545-2 for fire protection

MTBF

1850.1K hrs min. Telcordia SR-332 (Bellcore) ; 130.8K hrs min. MIL-HDBK-217F (25)

OTHERS DIMENSION

216*96.5*40mm (L*W*H)

NOTE

PACKING

1.19Kg ; 12pcs/15.3Kg/0.97CUFT

1. All parameters NOT specially mentioned are measured at 72VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1F & 47F parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSD-300-5 / -12)

5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on

a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to

perform these EMC tests, please refer to EMI testing of component power supplies.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

File Name:RSD-300-SPEC 2024-02-23

13

10

300W Railway Single Output DC-DC Converter

RSD-300 series

Mechanical Specification

15max.

130

8

tc

208
tc : Max. Case Temperature
216 208

15max. 2-R2.1
4
4 LED

28

40

Case No.205 Unit:mm

7.75

I/P 1
2
3

1 O/P

1

2

96.5

81

13

2

3

10

4

4-R2.1

Input Terminal Pin No. Assignment :

Pin No. Assignment

1 DC INPUT V+

2 DC INPUT V-

3

FG

Output Terminal Pin No. Assignment :

(For 12V, 24V, 48V)

(For 5V)

Pin No. Assignment

Pin No.

1 DC OUTPUT -V

1,2

2 DC OUTPUT +V

3,4

Assignment DC OUTPUT -V DC OUTPUT +V

Block Diagram

fosc : 130KHz

EMI

POWER

RECTIFIERS

+V

I/P

FILTER

SWITCHING

& FILTER

-V

FG

O.L.P.

PWM

DETECTION CIRCUIT

CONTROL

O.T.P.

O.V.P.

Input Fuse

There are one or two fuses connected in series to the positive input line, which are used to protect against abnormal surge. Fuse specifications of each model are shown

as below.

Type

Fuse Type

Reference and Rating

B

Fast

Littelfuse 257, 30A, 32V

C

Time-Lag

Conquer UDA-A, 16A, 250V

D

Time-Lag

Conquer UDA-A, 8A, 250V

E

Time-Lag

Conquer UDA-A, 20A, 250V

F

Time-Lag

Conquer UDA-A, 10A, 250V

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

Input Reverse Polarity Protection

There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.

Input Range and Transient Ability
The series has a wide range input capability. Within ±30% of rated input voltage, it can be executed at full-load operation and operate properly; with ±40% of rated input voltage, it can withstand that for 1 second.

Input Under-Voltage Protection

If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin, please refer to the cruve below.

RSD-300B-24
Vo 30

RSD-300C-24
Vo 30

RSD-300D-24
Vo 30

25

25

25

30

20

20

20

15

Turn On

15

Turn On

15

Turn On

Turn Off

Turn Off

Turn Off

10

10

10

5

12

13.5

0

Vin

11

12

13

14

15

16

17

5

24.2 25.8

0

Vin

23

25

27

29

31

33

35

5

53.5

56.2

0

Vin

50

55

60

65

70

RSD-300E-24
Vo 30

RSD-300F-24
Vo 30

25

25

20

20

15

Turn On

15

Turn On

Turn Off

Turn Off

10

10

5

18.6

20.9

0

Vin

17

19

21

23

25

27

29

5

39.1

41.8

0

Vin

37

39

41

43

45

47

49

Inrush Current
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up.
Hold-up Time
EN50155: 2007 version – D and F and E-5 types are in compliance with S2 level, while B and C and E types are in compliance with S1 level at full load output condition. To fulfil the requirements of S2 level, B and C and E types require de-rating their output load to 70%, please refer to the curve diagrams below.

RSD-300B-5

1100%0%
90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0ms

10ms

20ms 30ms

40ms 50ms 60ms

70ms 80ms

90ms

TIME

LOAD

RSD-300B-12

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0ms

10ms

20ms 30ms

40ms 50ms 60ms

70ms 80ms

TIME

LOAD

RSD-300B-24

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0ms

10ms

20ms 30ms

40ms 50ms 60ms

70ms 80ms

TIME

RSD-300B-48

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms

TIME

LOAD

RSD-300C-5

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms

TIME

LOAD

RSD-300C-12

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms

TIME

LOAD

LOAD

File Name:RSD-300-SPEC 2024-02-23

LOAD

LOAD

300W Railway Single Output DC-DC Converter

RSD-300 series

RSD-300C-24

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms

TIME

LOAD

RSD-300C-48

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms

TIME

LOAD

RSD-300E-12

100% 90% 80% 70% 60% 50% 40% 30% 20% 10%
0% 0ms

10ms 20ms 30ms 40ms

50ms 60ms 70ms 80ms 90ms

TIME

RSD-300E-24

RSD-300E-48

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms

10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms

LOAD

100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0ms

10ms 20ms 30ms 40ms 50ms

60ms 70ms 80ms 90ms

TIME

TIME

EN50155: 2017 version – Comply with S1 level

Output Voltage Adjustment
This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.

Efficiency vs Load & Vin Curve

The efficiency vs load & Vin curves of each model are shown as below.

RSD-300B-5

RSD-300B-12

95%

95%

90%

90%

EFFICIENCY

EFFICIENCY

85%

85%

3 1 .2 Vd c

80%

24Vdc

80%

1 6 .8 Vd c

75%

75%

70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

3 1 .2 Vd c 24Vdc 1 6 .8 Vd c

EFFICIENCY

RSD-300B-24
95%
90%
85%
80%
75%
70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

3 1 .2 Vdc 24Vdc 1 6 .8 Vdc

EFFICIENCY

EFFICIENCY

RSD-300B-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300C-24
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300D-12
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

3 1 .2 Vdc 24Vdc 1 6 .8 Vdc
6 2 .4 Vdc 48Vdc 3 3 .6 Vdc
143Vdc 110Vdc 6 7 .2 Vdc

EFFICIENCY

EFFICIENCY

EFFICIENCY

RSD-300C-5
95%
90%
85%
80%
75%
70% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

6 2 .4 Vd c 48Vdc 3 3 .6 Vd c

RSD-300C-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300D-24
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

6 2 .4 Vdc 48Vdc 3 3 .6 Vdc
143Vdc 110Vdc 6 7 .2 Vdc

EFFICIENCY

EFFICIENCY

EFFICIENCY

RSD-300C-12
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300D-5
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300D-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

6 2 .4 Vdc 48Vdc 3 3 .6 Vdc
143Vdc 110Vdc 6 7 .2 Vdc
143Vdc 110Vdc 6 7 .2 Vdc

EFFICIENCY

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

EFFICIENCY

EFFICIENCY

RSD-300E-5
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300E-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300F-24
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

4 6 .8 Vdc 36Vdc 2 5 .2 Vdc
4 6 .8 Vdc 36Vdc 2 5 .2 Vdc
9 3 .6 Vdc 72Vdc 5 0 .4 Vdc

EFFICIENCY

EFFICIENCY

EFFICIENCY

RSD-300E-12
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300F-5
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300F-48
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

4 6 .8 Vdc 36Vdc 2 5 .2 Vdc
9 3 .6 Vdc 72Vdc 5 0 .4 Vdc
9 3 .6 Vdc 72Vdc 5 0 .4 Vdc

EFFICIENCY

EFFICIENCY

RSD-300E-24
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
RSD-300F-12
95% 90% 85% 80% 75% 70%
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD

4 6 .8 Vdc 36Vdc 2 5 .2 Vdc
9 3 .6 Vdc 72Vdc 5 0 .4 Vdc

EFFICIENCY

Parallel and Series Connection
A.Operation in Parallel Since RSD-300 series don’t have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating.
1.Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.

I/P

+

EIN

PS1

D1

RL

I/P

I/P

+

PS2

D2

I/P

2.When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the supplier if you have this kind of application.
B.Operation in Series RSD-300 can be operated in series. Here are the methods of doing it: 1.Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads.

I/P

+

E IN

PS1

I/P

I/P

+

PS2

I/P

+V RL
COM
RL -V

2.Increase the output voltage (current does not change). Because RSD-300 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).

I/P

+

+V

E IN

PS1 V1 D1

I/P

I/P PS2
I/P

+ V2

V1+V2 RL
D2 -V

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

Overload Protection
If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it’s not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.
Vo(%)
100

Overload

50

region

Io(%)

0

50

100

150

Over Voltage Protection
The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.
Over Temperature Protection
The converter shuts off to protect itself when the built-in temperature sensor mounted on the main power transformer senses a high temperature. The output recovers automatically if the temperature drops below the limit.
LED Indicator
Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator. Green : normal operation; No signal: no power or failure.
Derating Curve
a.Single unit operation If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55 as operating under full load condition. It requires de-rating output current when ambient temperature is between 55-70, please refer to the de-rating curve as below.

100

100

80

80

60

60

40

40

20

20

-40

0

10

20

30

40

50 55 60 70 (HORIZONTAL) -30

AMBIENT TEMPERATURE ()

0

10

20

30

40

50

60

70

80 (HORIZONTAL)

Tcase ()

LOAD (%) RATED CURRENT (%)

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

Suitable installation methods are shown as below. Since RSD-300 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

b.Operate with additional iron plate If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70, RSD-300 series must be installed onto an iron plate on the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-300 series must be firmly mounted at the center of the iron plate. Unit:mm
M4*4

360

LOAD (%)
2

360

The load vs ambient temperature curve is shown as below.

100 80 60 40 20

-40

0

10

20

30

40

50

60 70 (HORIZONTAL)

AMBIENT TEMPERATURE ()
Suitable installation methods are shown as below. Since RSD-300 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

iron plate

File Name:RSD-300-SPEC 2024-02-23

300W Railway Single Output DC-DC Converter

RSD-300 series

Immunity to Environmental Conditions

Test method Cooling Test Dry Heat Test Damp Heat Test, Cyclic Vibration Test Increased Vibration Test Shock Test

Standard EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 EN 50155 section 12.2.4 (Column 2, Class TX) EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2
EN 50155 section 12.2.5 EN 60068-2-30
EN 50155 section 12.2.11 EN 61373
EN 50155 section 12.2.11 EN 61373
EN 50155 section 12.2.11 EN 61373

Test conditions
Temperature: -40 Dwell Time: 2 hrs/cycle
Temperature: 70 / 85 Duration: 6 hrs / 10min
Temperature: 25~55 Humidity: 90%~100% RH Duration: 48 hrs
Temperature: 19 Humidity: 65% Duration: 10 mins
Temperature: 19 Humidity: 65% Duration: 5 hrs
Temperature: 21± 3 Humidity: 65 ± 5% Duration: 30ms*18

Low Temperature Storage Test

EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1

Temperature: -40 Dwell Time: 16 hrs

Salt Mist Test

EN 50155 section 12.2.10 (Class ST4)

Temperature: 35±2 Duration: 96 hrs

Status No damage
PASS PASS PASS PASS PASS PASS PASS

EN45545-2 Fire Test Conditions

Test Items Items
Oxygen index test R22 Smoke density test
Smoke toxicity test R24 Oxygen index test R25 Glow-wire test R26 Vertical flame test

EN 45545-2:2013 EN ISO 4589-2:1996
EN 45545-2:2013 EN ISO 5659-2:2006
EN 45545-2:2013 NF X70-100:2006
EN 45545-2:2013 EN ISO 4589-2:1996
EN 45545-2:2013 EN 60695-2-11:2000
EN 45545-2:2013 EN 60695-11:2003

Standard

HL1 PASS PASS PASS PASS PASS PASS

Hazard Level HL2 PASS PASS PASS PASS PASS PASS

HL3 PASS PASS PASS PASS PASS PASS

File Name:RSD-300-SPEC 2024-02-23