MEAN WELL RS-75 series 75W Single Output Switching Power Supply Instruction Manual
MEAN WELL RS-75 series 75W Single Output Switching Power Supply

Features

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105℃ long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70℃
  • Withstand 5G vibration test
  • No load power consumption<0.5W
  • High efficiency, long life and high reliability
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTlN.aspx

SPECIFICATION

MODEL RS-75-3.3 RS-75-5 RS-75-12 RS-75-15 RS-75-24 RS-75-48
OUTPUT DC VOLTAGE 3.3V 5V 12V 15V 24V 48V
RATED CURRENT 15A 12A 6A 5A 3.2A 1.6A
CURRENT RANGE 0 ~ 15A 0 ~ 12A 0 ~ 6A 0 ~ 5A 0 ~ 3.2A 0 ~ 1.6A
RATED POWER 49.5W 60W 72W 75W 76.8W 76.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 3V ~ 3.6V 4.75 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 22 ~ 27.6V 42 ~ 54V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION                                 Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION                                 Note.5 ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 500ms, 30ms/230VAC        1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC14ms/115VAC at full load
INPUT VOLTAGE RANGE 88 ~ 264VAC125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 75% 79% 84.5% 86% 88.5% 89.5%
AC CURRENT (Typ.) 2A/115VAC       1.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTION OVERLOAD 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0~50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 SAFETY & EMC (Note 6) SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS MTBF 2918.8K hrs min.    Telcordia SR-332 (Bellcore) ; 569.6K hrs min.    MIL-HDBK-217F (25℃)
DIMENSION 129*98*38mm (L*W*H)
PACKING 0.41Kg; 30pcs/13.3Kg/0.86CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 0% to 100% rated load.
  6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies.(as available on http://www.meanwell.com)
  7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

 Specification

Terminal Pin No. Assignment

Pin No. Assignment
1 AC/l
2 AC/N
3 FG
4 DC OUTPUT -V
5 DC OUTPUT +V

Block Diagram

 Specification

Derating Curve

 Specification

Output Derating VS Input Voltage

 Specification

QR CODE

QR code

Logo

Documents / Resources

MEAN WELL RS-75 series 75W Single Output Switching Power Supply [pdf] Instruction Manual
RS-75 series 75W Single Output Switching Power Supply, RS-75 series, 75W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *