Features

  • Isolated output &GND for CH1,CH2
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit/Overload/ Over voltage
  • All using 105C long life electrolytic capacitors
  • Withstand 5G vibration test
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibility
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL RID-125-1224 RID-125-1248 RID-125-2448
 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2
DC VOLTAGE 12V 24V 12V 48V 24V 48V
RATED CURRENT 3.7A 3.7A 2.3A 2.3A 2A 2A
CURRENT RANGE            Note.3 0 ~ 7A 0 ~ 5A 0~ 7A 0 ~ 2.5A 0 ~ 4A 0 ~ 2.5A
RATED POWER                 Note.6 133.2W 138W 144W
RIPPLE & NOISE (max.) Note.2 120mVp-p 200mVp-p 120mVp-p 240mVp-p 200mVp-p 240mVp-p
VOLTAGE ADJ. RANGE CH1: 11.4 ~ 13.2V CH1: 11.4 ~ 13.2V CH1: 22.8 ~ 26.4V
VOLTAGE TOLERANCE Note.3 ±2.0% ±8.0% ±2.0% ±8.0% ±1.0% ±6.0%
LINE REGULATION           Note.4 ±0.5% ±1.0% ±0.5% ±1.0% ±0.5% ±1.0%
LOAD REGULATION         Note.5 ±1.0% ±5.0% ±1.0% ±5.0% ±1.0% ±5.0%
SETUP, RISE TIME 500ms, 20ms/230VAC           1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 36ms/230VAC           30ms/115VAC at full load
 

 

INPUT

VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch            248 ~ 373VDC(300VAC peak 5sec. No damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 85% 85% 86%
AC CURRENT (Typ.) 3A/115VAC          2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

PROTECTION

OVERLOAD 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE CH1: 13.8 ~ 16.2V CH1: 13.8 ~ 16.2V CH1: 27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

ENVIRONMENT

WORKING TEMP. -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 2755.4K hrs min.      Telcordia SR-332 (Bellcore) ; 425.8K hrs min.    MIL-HDBK-217F (25℃)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.7Kg; 20pcs/15Kg/0.85CUFT
NOTE
  1. All parameters NOT SpECially mentioned are measured at 230VAC Input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.(ln order to meet tolerance, it is recommended that CH1 load > 5% rated current.)
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
    a 360mm360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
    perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  9. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft)
    Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Features

  • Isolated output & GND for CH1,CH2
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit/ Overload /Over voltage
  • 170 % peak load for CH1
  • All using 105C long life electrolytic capacitors
  • Withstand 5G vibration test
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibility
  • 3 years warranty

GTIN CODE

MW Search: https://www.meanwel.com/service.G TIN.aspx

SPECIFICATION

MODEL RID-125-1205 RID-125-2405
 

 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH1 CH2
DC VOLTAGE 12V 5V 24V 5V
RATED CURRENT 9.2A 3A 4.6A 3A
CURRENT RANGE            Note.6 0 ~ 10.5A 0 ~ 3A 0 ~ 5.3A 0 ~ 3A
PEAK LOAD                        Note.9 15.6A 3A 7.8A 3A
RATED POWER 125.4W 125.4W
RIPPLE & NOISE (max.) Note.2 120mVp-p 80mVp-p 120mVp-p 80mVp-p
VOLTAGE ADJ. RANGE CH1: 11.4 ~ 13.2V CH1: 22.8 ~ 26.4V
VOLTAGE TOLERANCE Note.3 ±2.0% ±3.0% ±2.0% ±3.0%
LINE REGULATION           Note.4 ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION         Note.5 ±1.0% ±2.0% ±1.0% ±2.0%
SETUP, RISE TIME 500ms, 20ms/230VAC           1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 35ms/230VAC           30ms/115VAC at full load
 

 

INPUT

VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch            248 ~ 373VDC(300VAC peak 5sec., no damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 80% 83%
AC CURRENT (Typ.) 3A/115VAC          2A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

PROTECTION

OVERLOAD >165% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE CH1: 13.8 ~ 16.2V CH1: 27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on CH1 output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 7)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 218.2Khrs min.       MIL-HDBK-217F (25℃)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.7Kg; 20pcs/15Kg/0.85CUFT
NOTE
  1. All parameters NOT SpECially mentioned are measured at 230VAC Input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.(ln order to meet tolerance, it is recommended that CH1 load > 5% rated current.)
  4. Line regulation is measured from low line to high line at rated load.
  5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. Each output can work within current range. But total output power can’t exceed rated output power.
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
    a 360mm360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
    perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  9. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft)
    Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical SpecificationMEAN WELL RID-125 Series 125W-Dual-Output-Switching-Power-Supply-FIG- (4)

Block DiagramMEAN WELL RID-125 Series 125W-Dual-Output-Switching-Power-Supply-FIG- (5)

Derating CurveMEAN WELL RID-125 Series 125W-Dual-Output-Switching-Power-Supply-FIG- (6)

Static CharacteristicsMEAN WELL RID-125 Series 125W-Dual-Output-Switching-Power-Supply-FIG- (7)

File Name: RID-125-SPEC  2022-09-20

Documents / Resources

MEAN WELL RID-125 Series 125W Dual Output Switching Power Supply [pdf] User Guide
RID-125 Series, 125W Dual Output Switching Power Supply, RID-125 Series 125W Dual Output Switching Power Supply, Dual Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *