MEAN-WELL-LOGO

MEAN WELL RD-50 Series 50W Dual Output Switching Power Supply

MEAN-WELL-RD-50-Series-50W-Dual-Output-Switching-Power-Supply-PRODUCT

Specifications

  • Model: RD-50 series
  • Output Power: 50W
  • Output Voltage: CH1 (5V), CH2 (12V/24V)
  • Rated Current: CH1 (6A), CH2 (2A/1.4A)
  • Features: Universal AC input, Short circuit/Overload/Over voltage protection, LED power indicator
  • Efficiency: 78%-79%
  • Operating Temperature: Up to 70°C
  • Warranty: 3 years

Product Usage Instructions

Installation:

  1. Ensure the input power matches the specifications mentioned.
  2. Connect the output cables to the respective devices securely.

Power On

  1. Plug in the power supply to a compatible power source.
  2. Turn on the power supply using the switch.

Monitoring

  • Check the LED indicator for power status.
  • Monitor the output voltages to ensure they meet the requirements of connected devices.

Safety Precautions

  1. Do not overload the power supply beyond the rated current.
  2. Keep the power supply well-ventilated to prevent overheating.

Specifications

MODEL RD-50A RD-50B
 

 

 

 

 

 

 

 

OUTPUT

OUTPUT NUMBER CH1 CH2 CH1 CH2
DC VOLTAGE 5V 12V 5V 24V
RATED CURRENT 6A 2A 4A 1.4A
CURRENT RANGE                                        Note.3 0 ~ 6A 0 ~ 3A 0 ~ 6A 0 ~ 2A
RATED POWER 54W 53.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 150mVp-p
VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 ±2.0% ±7.0% ±2.0% ±8%
LINE REGULATION                                        Note.4 ±0.5% ±1.5% ±0.5% ±1.5%
LOAD REGULATION                                        Note.5 ±0.5% ±3.0% ±0.5% ±3.0%
SETUP, RISE TIME 500ms, 20ms/230VAC          1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.) 60ms/230VAC         10ms/115VAC at full load
 

 

 

INPUT

VOLTAGE RANGE 88 ~ 264VAC         125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY(Typ.) 78% 79%
AC CURRENT (Typ.) 1.3A/115VAC          0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 48A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
 

 

PROTECTION

 

OVERLOAD

110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
 

OVER VOLTAGE

CH1: 5.75 ~ 6.75V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
 

 

 

ENVIRONMENT

WORKING TEMP. -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)on +5V output
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

(Note 6)

SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/IEC 60950-1:2005, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
 

OTHERS

MTBF 2981.9K hrs min.      Telcordia SR-332 (Bellcore); 594.2K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION 99*97*36mm (L*W*H)
PACKING 0.41Kg; 45pcs/19.5Kg/0.94CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230V AC input, rated load, and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.

4.  Line regulation is measured from low line to high line at rated load.

5.  Load regulation is measured from 0% to 100% rated load.

6. The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed to ensure that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

7.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Features

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on 100% full load burn-in test
  • All using 105 C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 vears warranty

50W Dual Output Switching Power Supply

Mechanical Specification

MEAN-WELL-RD-50-Series-50W-Dual-Output-Switching-Power-Supply-FIG- (3)

Terminal Pin No. Assignment

Pin No. Assignment Pin No. Assignment
1 AC/L 4,6 DC OUTPUT COM
2 AC/N 5 DC OUTPUT +V2
3 FG     7 DC OUTPUT +V1
 

Block Diagram

MEAN-WELL-RD-50-Series-50W-Dual-Output-Switching-Power-Supply-FIG- (1)

  • Derating Curve
  • Output Derating VS Input Voltage

MEAN-WELL-RD-50-Series-50W-Dual-Output-Switching-Power-Supply-FIG- (2)

Downloaded from Arrow.com.

FAQS

  • Q: What should I do if the LED indicator does not light up?
    A: Check the input power connection and ensure it is securely plugged in. Verify that the power switch is turned on.
  • Q: Can I connect multiple devices to both output channels simultaneously?
    A: Yes, you can connect devices as long as the total load does not exceed the rated current for each channel.

Documents / Resources

MEAN WELL RD-50 Series 50W Dual Output Switching Power Supply [pdf] Owner's Manual
RD-50 Series, RD-50 Series 50W Dual Output Switching Power Supply, 50W Dual Output Switching Power Supply, Dual Output Switching Power Supply, Switching Power Supply, Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *