MEAN WELL PLC-30 Series Single Output LED Power Supply Owner’s Manual
MEAN WELL PLC-30 Series Single Output LED Power Supply

Features :

  • Universal AC input / Full range
  • Adjustable output voltage and current level
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Fully isolated plastic case with terminal block style of /10
  • Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (Pin225W)
  • Class 1 power unit, no FG
  • Class 2 power unit
  • 100% full load burn-in test
  • High reliability W GTIN
  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty

GTIN CODE

MW Search: hiips:/www.meannel.com’serviceGTIN.aspx
Symbols
Symbols

SPECIFICATION

MODEL PLC-30-9 PLC-30-12 PLC-30-15 PLC-30-20 PLC-30-24 PLC-30-27 PLC-30-36 PLC-30-48
OUTPUT DC VOLTAGE 9V 12V 15V 20V 24V 27V 36V 48V
CONSTANT CURRENT REGION Note.6 6.3 ~ 9V 8.4 ~ 12V 10.5 ~ 15V 14 ~ 20V 16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V
RATED CURRENT 3.3A 2.5A 2A 1.5A 1.25A 1.12A 0.84A 0.63A
CURRENT RANGE 0 ~ 3.3A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.5A 0 ~ 1.25A 0 ~ 1.12A 0 ~ 0.84A 0 ~ 0.63A
RATED POWER 29.7W 30W 30W 30W 30W 30.24W 30.24W 30.24W
RIPPLE & NOISE (max.) Note.2 2.6Vp-p 2Vp-p 2.6Vp-p 2.6Vp-p 2.4Vp-p 2.3Vp-p 3.6Vp-p 3.7Vp-p
VOLTAGE ADJ. RANGE Note.5 8.55 ~ 9.9V 11.4 ~ 13.2V 14.5 ~ 16.5V 19 ~ 22V 22.8 ~ 26.4V 25.65 ~ 29.7V 34.2 ~ 39.6V 45.6 ~ 52.8V
CURRENT ADJ. RANGE Note.5 2.475 ~ 3.399A 1.875 ~ 2.575A 1.5 ~ 2.06A 1.125 ~ 1.545A 0.938 ~ 1.288A 0.84 ~ 1.1536A 0.63 ~ 0.865A 0.473 ~ 0.649A
VOLTAGE TOLERANCE Note.3 ±10%
LINE REGULATION ±3.0%
LOAD REGULATION ±5.0%
SETUP TIME 500ms / 230VAC  3000ms / 115VAC at full load
INPUT VOLTAGE RANGE        Note.4 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to “Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading¾70% at 115VAC/230VAC input
EFFICIENCY (Typ.) 80% 82.5% 83.5% 84% 84% 84.5% 85% 85.5%
AC CURRENT (Typ.) 0.4A/115VAC 0.2A/230VAC
INRUSH CURRENT (Typ.) COLD START 35A(width=25μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER 64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <0.5mA / 240VAC
PROTECTION OVER CURRENT 100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE 10 ~ 14V 14 ~ 17V 17 ~ 22V 23 ~ 26V 27 ~ 34V 31 ~ 35V 40 ~ 50V 53 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +50℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.06%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS UL1310, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (Pin¾25W), Class D (>70% load) ;BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61547, light industry level, EAC TP TC 020
OTHERS MTBF 4293.1K hrs min. Telcordia SR-332 (Bell core)  625.5Khrs min.  MIL-HDBK-217F (25℃)
DIMENSION 160*46*30mm (L*W*H)
PACKING 0.2Kg; 70pcs/15Kg/0.96CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
  5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
  6. Please refer to “DRIVING METHODS OF LED MODULE”.
  7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
    (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
  9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
  10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  11. PLC-30-9 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification
erminal Pin No. Assignment (TB1) :
SWITCHLAB MB310-75002

Pin No. Assignment
1 AC/N
2 AC/L

Terminal Pin No. Assignment (TB2):
SWITCHLAB MB310-75002

Pin No. Assignment
1 +V
2 -V

Block Diagram

Block Diagram
fosc: 39KHz(115VAC) 53KHz(230VAC)

Derating Curve

Derating Curve
AMBIENT TEMPERATURE (°C)

Static Characteristics

Static Characteristics
INPUT VOLTAGE (V) 60Hz

Power Factor Characteristic

Constant Current Mode
Power Factor Characteristic

EFFICIENCY vs LOAD (48V Model)

PLC-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.
EFFICIENCY vs LOAD (48V Model)

DRIVING METHODS OF LED MODULE

This LED power supply is suggested to working constant current mode area (CC)to drive the LEDs.

In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
Typical LED power supply |-V curve
Typical LED power supply |-V curve