Specifications
  • Model:
    • PID-250A
    • PID-250B
    • PID-250C
    • PID-250D
  • Output Number:
    • CH1, CH2
    • CH1, CH2
    • CH1, CH2
    • CH1, CH2
  • DC Voltage:
    • 12V, 5V
    • 24V, 5V
    • 36V, 5V
    • 48V, 5V

Product Usage Instructions

Installation

  1. Ensure the input voltage matches the specified range (90 ~ 264VAC).
  2. Connect the DC output terminals (CH1, CH2) to your devices following the correct polarity.

Operation

  1. Power on the device by connecting it to a suitable power source.
  2. Use the remote control for CH1 if needed.

Maintenance
Regularly check for dust accumulation and ensure proper ventilation around the product for cooling.

FAQ

  • Q: What is the input efficiency of the PID-250 model?
    A: The input efficiency is typically 83% for this model.
  • Q: How many years of warranty does the product come with?
    A: The product comes with a 3-year warranty.

250W Isolated Dual Output with PFC Function
PID-250

Features

  • Universal AC input / Full range
  • Isolated output & GND for CH1,CH2
  • Built-in active PFC function, PF>0.92
  • Protections:Short circuit / Overload / Over voltage / Over temperature
  • Remote control for CH1
  • Peak load 170% for CH1 within 10 sec.
  • Cooling by free air convection
  • 100% full load burn-in test
  • 2 vears warrantyMEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (1)

GTIN CODE 
MW Search: https://www.meanwell.com/serviceGTIN.aspx

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (2)

SPECIFICATION

MODEL PID-250A PID-250B PID-250C PID-250D
OUTPUT OUTPUT NUMBER CH1 CH2 CH1 CH2 CH1 CH2 CH1 CH2
DC VOLTAGE 12V 5V 24V 5V 36V 5V 48V 5V
RATED CURRENT 15A(Peak 20A) 5A 9.4A(Peak 16.7A) 5A 6.3A(Peak 11.1A) 5A 4.7A(Peak 8.4A) 5A
CURRENT RANGE           Note.6 0 ~ 15A (Peak 20A) 0 ~ 5A 0 ~ 9.4A (Peak 16.7A) 0 ~ 5A 0 ~ 6.3A (Peak 11.1A) 0 ~ 5A 0 ~ 4.7A (Peak 8.4A) 0 ~ 5A
RATED POWER 205W 250.6W 251.8W 250.6W
RIPPLE & NOISE (max.) Note.2 120mVp-p 50mVp-p 150mVp-p 50mVp-p 200mVp-p 50mVp-p 200mVp-p 50mVp-p
VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 4.75 ~ 5.25V 21.6 ~ 26.4V 4.75 ~ 5.25V 32.4 ~ 39.6V 4.75 ~ 5.25V 43.2 ~ 52.8V 4.75 ~ 5.25V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±2.0% ±1.0% ±2.0% ±1.0% ±2.0% ±1.0% ±2.0%
SETUP, RISE TIME 2500ms, 60ms/115VAC       1200ms, 60ms/230VAC
HOLD UP TIME (Typ.) 30ms at full load
INPUT VOLTAGE RANGE            Note.5 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≧0.92/230VAC            PF≧0.97/115VAC at full load
EFFICIENCY(Typ.) 83% 86% 86% 86%
AC CURRENT (Typ.) 3A/115VAC         1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 58A/230VAC
LEAKAGE CURRENT <3.5mA / 240VAC
PROTECTION OVERLOAD
  • CH1: 105 ~ 170% rated output power
  • Normally work within 10 sec and then shut down, re-power on to recover
  • Over 180% rated power or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover
CH2: 101 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 13.8 ~ 16.2V 5.5 ~ 6.75V 27.6 ~ 32.4V 5.5 ~ 6.75V 40 ~ 48V 5.5~ 6.75V 54 ~ 64.8V 5.5 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover for CH1 ; Hiccup mode, recovers automatically afer fault condition is removed for CH2(by zener diode clamp)
OVER TEMPERATURE Shut down o/p voltage(CH1), recovers automatically after temperature goes down
FUNCTION REMOTE CONTROL CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on; when CH2 is malfunction, CH1 will be shut down
 ENVIRONMENT WORKING TEMP. -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.05%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min each along X, Y, Z axes
SAFETY & EMC (Note 4) SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level,  EAC TP TC 020
OTHERS MTBF 2091.7K hrs min.       Telcordia SR-332 (Bellcore) ; 150.5K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION 222*95*40mm (L*W*H)
PACKING 0.74Kg; 18pcs/14.3Kg/0.98CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EM testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Derating may be needed under low input voltage. Please check the derating curve for more details.
  6. Peak current should reduce to 150% of rated value if the input voltage <110VAC.
  7. Heat Sink HS1,HS2,HS3 can not be shorted.
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (3)

Unit:mm

AC Input Connector (CN1) : JST B5P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 FG JST VHR M or equivalent JST SVH-21T-P1.1 or equivalent
2,4 No Pin
3 AC/N
5 AC/L

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (4): Grounding Required
DC Output Connector (CN51) : JST B10P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2,3 COM1 JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
4,5,6 V1
7,8 COM2
9,10 V2

Remote ON/OFF Connector(CN52):JST B2B-XH or equivalent

Pin No. Status Mating Housing Terminal
PIN1,2 (Short) V1: OFF V2: ON JST XHP or equivalent JST SXH-001T-P0.6 or equivalent
PIN1,2 (Open) V1: ON V2: ON
SVR1 For CH1
SVR2 For CH2
  1. HS1,HS2,HS3 cannot be shorted.
  2. CN1:Pin1 is safety ground. For better EMC performance,Please secure an electrical connection between M1,M2,M3,and chassis grounding.

Block Diagram

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (5)

Derating Curve

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (6)

Output Derating VS Input Voltage

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply- (7)

File Name:PID-250-SPEC 2024-02-23

Documents / Resources

MEAN WELL PID-250 250W Isolated Dual Output Power Supply [pdf] Owner's Manual
PID-250, PID-250 250W Isolated Dual Output Power Supply, 250W Isolated Dual Output Power Supply, Isolated Dual Output Power Supply, Dual Output Power Supply, Output Power Supply, Power Supply, Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *